The industry-standard commercial ATS. 30-4000A, open/closed transition, UL 1008 listed. The most widely specified transfer switch for hospitals, data centers, and critical facilities.
The ASCO 7000 Series is the most widely specified automatic transfer switch in North American commercial/industrial power. Manufactured by ASCO Power Technologies (now Schneider Electric), it covers 30A through 4000A in a single product family — from small retail loads to hospital mains and data center distribution.
When an engineer writes "transfer switch" on a spec sheet without a brand preference, the electrical contractor quotes an ASCO 7000. It's the default for a reason: universal familiarity, broadest accessory catalog, proven field history across millions of installations.
Range: 30-4000A from one product family means one spec, one training program, one parts ecosystem for an entire facility regardless of how many ATS it needs
Transition flexibility: open, closed, or delayed transition selectable per application within the same frame
Withstand ratings: 3-cycle standard, 18-cycle and 30-cycle options for high available fault current
Communications: native Modbus/SNMP/BACnet covers every BMS integration scenario
Accessories: bypass/isolation, load centers, programmatic load sequencing, ground fault — more options than any competitor
The ASCO 7000 is installed at the majority of our commercial service accounts. We exercise these switches during annual preventive maintenance: verify transfer timing, check contact condition, test controls, and verify communication with the generator controller. The most common service issue: contact erosion on high-cycle switches (monthly exercising over many years wears contacts) and occasional solenoid coil replacement. Parts are always available — ASCO maintains the largest ATS parts inventory in the industry.
Frequently Asked Questions
What amperage range does the ASCO 7000 come in?
30A through 4000A — the broadest range in the industry from a single product family. This means you can specify ASCO 7000 for everything from a small retail transfer to a 4000A hospital main, with consistent controls and accessories across the range.
What's the difference between open and closed transition?
Open transition (standard): utility disconnects before generator connects — brief power interruption (~100ms). Closed transition (option): utility and generator briefly parallel during transfer — zero interruption to load. Closed transition requires utility company approval and is standard for data centers and hospitals.
How does the ASCO 7000 compare to the ASCO 300?
The 300 Series is residential/light-commercial (up to 400A, simpler controls). The 7000 Series is the commercial/industrial workhorse (30-4000A, advanced controls, multiple transition types, communications, POWERQUEST monitoring). For anything above 400A or requiring closed transition, it's the 7000.
What communications does the ASCO 7000 support?
Modbus TCP/IP, SNMP, and BACnet IP via the Accessory 107G Monitoring Gateway. ASCO POWERQUEST is a separate critical power management platform for multi-device monitoring and control. Together they provide full BMS/SCADA/IT integration for real-time status, remote diagnostics, and automated alerting.
Why is the ASCO 7000 the 'industry standard'?
Market share, spec familiarity, and accessory ecosystem. More engineers specify ASCO 7000 than any other ATS. This means: every electrical contractor knows how to install it, parts are universally available, and the accessories catalog (bypass, isolation, load centers) is the largest in the industry.
Found in these gensets
Generator models that ship with or are commonly paired with the ASCO 7000 Series Transfer Switch.
B
Blue Star Power Systems
New
Blue Star GM100-03
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby generator (80 kW on LP) from Blue Star Power Systems. PSI 5.7LTCAC turbocharged charge-air-cooled V8, Stamford UCI274C alternator, DSE DCP7310 controller, 208-600V output.
55 kW prime / 60 kW standby natural gas / LP generator from Blue Star Power Systems. PSI 5.7L eight-cylinder V8 with catalyst/silencer, Stamford UCI224E alternator, DSE DCP7310 controller, 208-600V output.
40 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 3029HG530 2.9L inline-three with DOC/DPF, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
B
Blue Star Power Systems
New
Blue Star JD60-04FT4
60 kW standby · Diesel · Liquid-cooled
60 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 4045HFG04 4.5L inline-four with SCR/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
B
Blue Star Power Systems
New
Blue Star JD80-03FT4
80 kW standby · Diesel · Liquid-cooled
80 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 4045HFG04 4.5L inline-four with SCR/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
B
Blue Star Power Systems
New
Blue Star NG1050-01
1.1 MW standby · Natural Gas / LPG · Liquid-cooled
1050 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 53L V16 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 480-4160V.
1.1 MW standby · Natural Gas / LPG · Liquid-cooled
900 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 53L V16 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 480-4160V.
1250 kW natural-gas-only standby generator from Blue Star Power Systems. PSI 53LHO high-output V16 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 480-4160V. LP not available.
150 kW standby · Natural Gas / LPG · Liquid-cooled
125 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 8.1LT inline-six, DSE DCP7310 controller, 208-600V, continuous prime duty.
200 kW standby · Natural Gas / LPG · Liquid-cooled
175 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 11.1L inline-six, DSE DCP7310 controller, 208-600V, continuous prime duty.
265 kW standby · Natural Gas / LPG · Liquid-cooled
265 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 14.6L turbocharged V8, DSE DCP7310 controller, structural steel base, 208-600V.
265 kW standby · Natural Gas / LPG · Liquid-cooled
250 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 14.6L V8, DSE DCP7310 controller, structural steel base, continuous prime duty.
300 kW standby · Natural Gas / LPG · Liquid-cooled
300 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 14.6L turbocharged V8, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
300 kW standby · Natural Gas / LPG · Liquid-cooled
260 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 14.6L V8, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
350 kW natural gas standby generator from Blue Star Power Systems. PSI 14.6LHO high-output V8, DSE DCP7310 controller, structural steel base, three-phase 208-600V. Natural gas only — no LP rating.
400 kW standby · Natural Gas / LPG · Liquid-cooled
400 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 21.9L turbocharged V12, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
400 kW standby · Natural Gas / LPG · Liquid-cooled
375 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 21.9L V12, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
425 kW standby · Natural Gas / LPG · Liquid-cooled
425 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 21.9L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
450 kW standby · Natural Gas / LPG · Liquid-cooled
450 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 21.9L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
500 kW standby · Natural Gas / LPG · Liquid-cooled
500 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
500 kW standby · Natural Gas / LPG · Liquid-cooled
450 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
500 kW natural-gas-only standby generator from Blue Star Power Systems. PSI 21.9LHO high-output V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V. LP not available.
600 kW standby · Natural Gas / LPG · Liquid-cooled
600 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
600 kW standby · Natural Gas / LPG · Liquid-cooled
540 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
650 kW standby · Natural Gas / LPG · Liquid-cooled
650 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
650 kW standby · Natural Gas / LPG · Liquid-cooled
550 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
800 kW standby · Natural Gas / LPG · Liquid-cooled
800 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 40L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-4160V.
800 kW standby · Natural Gas / LPG · Liquid-cooled
660 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 40L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-4160V.
35 kW prime / 40 kW standby natural gas / LP generator from Blue Star Power Systems. PSI 4.3L six-cylinder V6 engine with catalyst/silencer, Stamford UCI224C alternator, DSE DCP7310 controller, 208-600V output.
100 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD581VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
B
Blue Star Power Systems
New
Blue Star VD125-04FT4
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD582VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
B
Blue Star Power Systems
New
Blue Star VD150-04FT4
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD881VE 7.7L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD200-04FT4
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1180VE 10.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD230-01
230 kW standby · Diesel · Liquid-cooled
230 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD851GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD250-03
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD852GE 7.7L inline-six, DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD250-04FT4
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1381VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD275-01
275 kW standby · Diesel · Liquid-cooled
275 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD853GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD300-01
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1351GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD300-02FT4
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel standby generator. Volvo Penta TAD1373VE 12.8L inline-six, 208-600V output, with Basler DGC-2020 controller and SCR aftertreatment.
300 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1383VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
350 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1352GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD400-01
400 kW standby · Diesel · Liquid-cooled
400 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1353GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD450-01
450 kW standby · Diesel · Liquid-cooled
450 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1650GE 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD500-01
500 kW standby · Diesel · Liquid-cooled
500 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1641GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD550-01
550 kW standby · Diesel · Liquid-cooled
550 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1642GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD550-04FT4
550 kW standby · Diesel · Liquid-cooled
550 kW standby / 500 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1682GE 16.12L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, three-phase 208-600V.
600 kW EPA Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1643GE 16.1L inline-six, 208-4160V output, available with medium-voltage option.
Tier 23-phaselarge-commercialhospital
B
Blue Star Power Systems
New
Blue Star VD600-03
600 kW standby · Diesel · Liquid-cooled
600 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1644GE 16.1L inline-six with dual-stage turbo, DSE DCP7310 controller, 208-600V.
Tier 23-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD600-04FT4
600 kW standby · Diesel · Liquid-cooled
600 kW standby / 570 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1683GE 16.12L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, three-phase 208-600V.
700 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1744GE 17.3L inline-six with Common Rail injection, DSE DCP7310 controller, 208-600V.
Tier 23-phaselarge-commercialhospital
C
Caterpillar
New
Cat 3516C
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby generator with Cat 3516C V-16 engine. The largest Cat genset platform for mission-critical data centers and industrial power.
Tier 23-phasedata-centerhospital-large
C
Caterpillar
New
Cat C15
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby generator with Cat C15 ACERT engine. Large commercial standby for hospitals, high-rises, and municipal infrastructure.
Tier 23-phasehospitalhigh-rise
C
Caterpillar
New
Cat C32
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby generator with Cat C32 ACERT V-12 engine. Mission-critical platform for data centers, hospitals, and large campus power.
Tier 23-phasedata-centerhospital
C
Cummins
New
Cummins C200 N6
200 kW standby · Natural Gas / LPG · Liquid-cooled
200 kW natural gas/propane commercial standby generator. Cummins' flagship gaseous unit with QSJ8.9G engine and PowerCommand 2.3 controller.