Media & Telecom Backup Power
Generator Solutions for Media & Telecommunications
Broadcast signals and cellular networks cannot tolerate interruptions. PowerGen provides clean, reliable backup power systems trusted by leading media and telecom companies acrossNorthern California and Nevada.
Trusted by Leading Media & Telecom Companies
Why Backup Power Is Critical for Media & Telecom
Broadcast Continuity
Live broadcasts cannot pause for a power outage. News, emergency alerts, and scheduled programming all depend on continuous, reliable power to reach audiences without interruption.
Cell Tower Uptime
Cell towers serve thousands of subscribers and carry 911 traffic. FCC mandates and carrier SLAs require backup power that activates within seconds of a grid failure.
Data Transmission
Fiber nodes, microwave relays, and satellite uplinks form the backbone of modern communication. Even brief outages can cascade across networks, disrupting service for millions.
Studio Operations
Production studios house sensitive recording equipment, post-production systems, and climate-controlled media storage. Power quality directly impacts content integrity and production timelines.
Facility Types We Serve
From downtown broadcast centers to remote hilltop cell sites, we engineer backup power for every media and telecom environment.
Broadcast Studios
Television and radio broadcast facilities with mission-critical transmission equipment, editing suites, and live production infrastructure.
Cell Towers & Base Stations
Macro sites, small cells, and distributed antenna systems that require compact, reliable generators with remote monitoring capabilities.
Data Transmission Facilities
Central offices, fiber hubs, and switching centers that route voice and data traffic across regional and national networks.
Production Stages
Film and television production stages where high-draw lighting, sound systems, and climate control demand clean, high-capacity power.
Remote Broadcast Locations
Temporary and semi-permanent broadcast sites for news, sports, and events where portable or trailer-mounted generators provide reliable field power.
Engineered for Signal Integrity
Clean Power (THD <5%)
Sensitive broadcast and telecom equipment requires exceptionally clean power. Our generators deliver total harmonic distortion below 5%, protecting signal integrity and equipment longevity.
UPS Integration
Seamless coordination with uninterruptible power supply systems ensures zero-gap transitions. We design generator-UPS architectures that eliminate even momentary power loss.
Redundant Systems
N+1 and 2N redundancy configurations provide failover protection for mission-critical sites. If one generator goes down, backup units engage automatically.
Remote Monitoring
Cellular and IP-based monitoring systems provide real-time generator status, fuel levels, and fault alerts. NOC teams can track every site from a single dashboard.
High-Capacity Output
From compact 20kW cell tower units to multi-megawatt broadcast facility systems, we size and install generators to match your exact power requirements.
Generators for Media & Telecom
Continuous power for broadcast, transmission, and network infrastructure.

Caterpillar
Cat C3.3
45 kW compact diesel with CAT C3.3 engine. Premium build quality. Best resale value. ~200 US dealer network.
45 kW standby · Diesel · Liquid-cooled
45 kW diesel standby generator with Cat C3.3 turbocharged inline-4 engine. Versatile platform for commercial standby and prime power applications.

Caterpillar
Cat C4.4
80 kW compact diesel with CAT C4.4 turbo inline-4. Premium build quality. Best resale value. ~200 US dealer network.
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby generator with Cat C4.4 turbocharged inline-4 engine. Reliable platform for commercial standby and prime power applications.

Cummins
Cummins C60 N6
60 kW natural gas with full Cummins vertical integration. QuietConnect-class sound levels. No diesel storage needed.
60 kW standby · Natural Gas / LPG · Liquid-cooled
60 kW natural gas/propane standby generator with Cummins QSJ5.9G 5.9L inline-6 engine. PowerCommand 1.1 control, UL 2200 listed, NFPA 110 Level 1 capable. Sound-attenuated aluminum enclosure.

Cummins
Cummins QSL9
300 kW diesel with QSL9 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
300 kW standby · Diesel · Liquid-cooled
300 kW standby / 275 kW prime diesel generator with QSL9-G7 8.8L inline-6 Bosch HPCR engine. EPA Tier 3 / EU Stage IIIA compliant, Holset HX40 wastegated turbo, 24V starting. Engine dimensions 2157 x 1126 x 1562 mm, dry weight 940 kg.

Blue Star Power Systems
Blue Star JD100-01
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine with charge air cooling, Stamford UCI274 alternator, DSE DCP7310 controller.

Blue Star Power Systems
Blue Star JD150-01
Open Basler controller + John Deere 6068 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HF285 6-cylinder engine, Stamford UCI274/UCDI274 alternator, DSE DCP7310 controller.
Resources & Services
Related Guides
Our Services
Recommended Product Families
kohler
KD Series (Industrial Diesel)
Kohler-engineered megawatt-class diesel gensets from 900 to 4000 kW for mission-critical facilities.
900–4000 kW
Clean power output for broadcast and telecom equipment
View specs →generac
SD Series (Industrial Diesel)
Generac's broadest diesel standby lineup — 10 to 1500 kW across four engine families for commercial and industrial applications.
10–1500 kW
Cost-effective standby for cell tower and headend sites
View specs →Application Engineering
Multi-brand engineering support on every project
Broadcast and telecom infrastructure require clean power output with low THD and continuous-duty ratings. Our engineers specify generators that maintain signal integrity across all site types.
Keep Your Signal Strong