Data Center Backup Power
Generator Solutions for Data Centers
Your data center promises always-on availability. PowerGen delivers the backup power infrastructure to keep that promise — with N+1 redundancy, automatic transfer, and proactive maintenance that satisfies the most demanding uptime SLAs.
Trusted by Leading Data Center Operators
Why Data Centers Cannot Afford Power Gaps
Uptime SLA Commitments
Your customers expect 99.999% availability. A single unplanned outage can breach SLAs, trigger penalties, and erode trust built over years.
Data Integrity
Abrupt power loss risks corrupted databases, failed transactions, and lost writes. Clean backup power ensures graceful operations during grid failures.
Cooling Continuity
Servers generate enormous heat. Losing cooling for even minutes can trigger thermal shutdowns and hardware damage across entire racks.
Compliance & Audits
SOC 2, Uptime Institute certifications, and NFPA 110 all require documented, tested backup power. Non-compliance jeopardizes your certifications.
Built for Mission-Critical Uptime
Every component of your backup power system is designed, installed, and maintained to eliminate single points of failure.
N+1 Redundancy Design
We design systems with redundant generators so a single unit failure never takes your facility offline. True N+1 means no single point of failure.
Automatic Transfer Switches
Sub-10-second transfer to generator power with automatic retransfer when utility is restored. Coordinated with your UPS for zero-gap coverage.
Load Bank Testing
Regular full-load testing verifies your generators can handle real-world demand — not just idle at no load. We test to 100% of rated capacity.
Fuel Management
Fuel polishing, tank monitoring, and scheduled deliveries ensure your generators have clean, fresh fuel ready for extended runtime events.
Compliance & Certification Support
Uptime Institute Tiers
Tier II through Tier IV facilities require increasingly robust power redundancy. We design and maintain systems that meet your target tier certification.
NFPA 110
Emergency and standby power systems must be installed, tested, and maintained per NFPA 110. Our programs cover monthly testing and annual load bank verification.
SOC 2 Type II
Auditors verify that backup power is tested, documented, and reliable. Our detailed service reports provide the evidence your compliance team needs.
Generators for Data Centers
Mission-critical standby power for colocation, hyperscale, and edge deployments.

Caterpillar
Cat 3412C
800 kW Cat diesel with 3412C V-12. Updated 3400-series with EMCP 4 controls. Proven reliability.
800 kW standby · Diesel · Liquid-cooled
800 kW standby diesel generator with Cat 3412C V12 engine, 27.0L displacement. The current-generation 3412 with upgraded controls and improved fuel efficiency.

Caterpillar
Cat 3508B
1 MW Cat diesel with 3508B V-8. Upgraded 3500-series for data centers. Megawatt from 8 cylinders.
1 MW standby · Diesel · Liquid-cooled
1000 kW standby diesel generator with Cat 3508B V8 engine, 34.5L displacement. Built for data centers, hospitals, and paralleling arrays requiring 1 MW per unit.

Cummins
Cummins C1000 D6
1 MW diesel with QST30 V-12 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby generator with QST30 30L V-12 engine. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications requiring megawatt-class power.

Cummins
Cummins C1100 D6
1100 kW diesel with QSK38 V-12 engine. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.
1.1 MW standby · Diesel · Liquid-cooled
1100 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.

Generac
Generac MD1250
1250 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture for multi-megawatt systems.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi 49.0L V12 engine for N+1 redundancy.

Generac
Generac MD1500
1500 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture for multi-megawatt systems.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi 65.4L V16 engine for N+1 redundancy.
Resources & Services
Recommended Product Families
cummins
Cummins D6 Commercial Diesel
80–350 kW Tier 3 commercial diesel from Cummins — QSB5, QSB7, and QSG12 platforms with PowerCommand integration.
80–350 kW
Paralleling capability for N+1 redundancy configurations
View specs →kohler
KD Series (Industrial Diesel)
Kohler-engineered megawatt-class diesel gensets from 900 to 4000 kW for mission-critical facilities.
900–4000 kW
Premium power quality with sub-3% THD for sensitive IT loads
View specs →Application Engineering
Multi-brand engineering support on every project
Data centers require paralleling-capable generators with sub-3% THD and N+1 redundancy. Our engineers size and configure the right system for your uptime tier.
Keep Your Data Center Always On
PowerGen designs and maintains backup power systems for the most demanding uptime requirements. Let us build a solution for your facility.