Commercial generator system for data center backup power

Data Center Backup Power

Generator Solutions for Data Centers

Your data center promises always-on availability. PowerGen delivers the backup power infrastructure to keep that promise — with N+1 redundancy, automatic transfer, and proactive maintenance that satisfies the most demanding uptime SLAs.

Trusted by Leading Data Center Operators

AWSVantage Data CentersNTT

Why Data Centers Cannot Afford Power Gaps

Uptime SLA Commitments

Your customers expect 99.999% availability. A single unplanned outage can breach SLAs, trigger penalties, and erode trust built over years.

Data Integrity

Abrupt power loss risks corrupted databases, failed transactions, and lost writes. Clean backup power ensures graceful operations during grid failures.

Cooling Continuity

Servers generate enormous heat. Losing cooling for even minutes can trigger thermal shutdowns and hardware damage across entire racks.

Compliance & Audits

SOC 2, Uptime Institute certifications, and NFPA 110 all require documented, tested backup power. Non-compliance jeopardizes your certifications.

Built for Mission-Critical Uptime

Every component of your backup power system is designed, installed, and maintained to eliminate single points of failure.

N+1 Redundancy Design

We design systems with redundant generators so a single unit failure never takes your facility offline. True N+1 means no single point of failure.

Automatic Transfer Switches

Sub-10-second transfer to generator power with automatic retransfer when utility is restored. Coordinated with your UPS for zero-gap coverage.

Load Bank Testing

Regular full-load testing verifies your generators can handle real-world demand — not just idle at no load. We test to 100% of rated capacity.

Fuel Management

Fuel polishing, tank monitoring, and scheduled deliveries ensure your generators have clean, fresh fuel ready for extended runtime events.

Compliance & Certification Support

Uptime Institute Tiers

Tier II through Tier IV facilities require increasingly robust power redundancy. We design and maintain systems that meet your target tier certification.

NFPA 110

Emergency and standby power systems must be installed, tested, and maintained per NFPA 110. Our programs cover monthly testing and annual load bank verification.

SOC 2 Type II

Auditors verify that backup power is tested, documented, and reliable. Our detailed service reports provide the evidence your compliance team needs.

Generators for Data Centers

Mission-critical standby power for colocation, hyperscale, and edge deployments.

Caterpillar Cat 3412C 800 kW liquid-cooled standby generator

Caterpillar

Cat 3412C

800 kW Cat diesel with 3412C V-12. Updated 3400-series with EMCP 4 controls. Proven reliability.

800 kW standby · Diesel · Liquid-cooled

800 kW standby diesel generator with Cat 3412C V12 engine, 27.0L displacement. The current-generation 3412 with upgraded controls and improved fuel efficiency.

Tier 23-phasedata-centerhospital
Caterpillar Cat 3508B 1 MW liquid-cooled standby generator

Caterpillar

Cat 3508B

1 MW Cat diesel with 3508B V-8. Upgraded 3500-series for data centers. Megawatt from 8 cylinders.

1 MW standby · Diesel · Liquid-cooled

1000 kW standby diesel generator with Cat 3508B V8 engine, 34.5L displacement. Built for data centers, hospitals, and paralleling arrays requiring 1 MW per unit.

Tier 23-phasedata-centerhospital
Cummins Cummins C1000 D6 1 MW liquid-cooled standby generator

Cummins

Cummins C1000 D6

1 MW diesel with QST30 V-12 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.

1 MW standby · Diesel · Liquid-cooled

1000 kW diesel standby generator with QST30 30L V-12 engine. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications requiring megawatt-class power.

Tier 23-phasedata-centerhospital
Cummins Cummins C1100 D6 1.1 MW liquid-cooled standby generator

Cummins

Cummins C1100 D6

1100 kW diesel with QSK38 V-12 engine. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.

1.1 MW standby · Diesel · Liquid-cooled

1100 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.

Tier 23-phasedata-centerhospital
Generac Generac MD1250 1.3 MW liquid-cooled standby generator

Generac

Generac MD1250

1250 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture for multi-megawatt systems.

1.3 MW standby · Diesel · Liquid-cooled

1250 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi 49.0L V12 engine for N+1 redundancy.

Tier 23-phasecommercial-standbyindustrial
Generac Generac MD1500 1.5 MW liquid-cooled standby generator

Generac

Generac MD1500

1500 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture for multi-megawatt systems.

1.5 MW standby · Diesel · Liquid-cooled

1500 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi 65.4L V16 engine for N+1 redundancy.

Tier 23-phasecommercial-standbyindustrial

Recommended Product Families

Calculate N+1 redundancy requirements

Application Engineering

Multi-brand engineering support on every project

Data centers require paralleling-capable generators with sub-3% THD and N+1 redundancy. Our engineers size and configure the right system for your uptime tier.

Keep Your Data Center Always On

PowerGen designs and maintains backup power systems for the most demanding uptime requirements. Let us build a solution for your facility.