Caterpillar · Cat 3400 Series (Diesel)

Cat 3412C

800 kW standby / 725 kW prime · Diesel · Liquid-cooled

800 kW standby diesel generator with Cat 3412C V12 engine, 27.0L displacement. The current-generation 3412 with upgraded controls and improved fuel efficiency.

Caterpillar Cat 3412C generator — specifications and details
Standby power
800 kW / 725 kW prime
Voltage options
277/480V, 346/600V
Frequency / Phase
60 Hz · 3-phase
Engine
Caterpillar 3412C · 27L
EPA / Emissions
Tier 2

Overview#

The Cat 3412C is an 800-kilowatt standby diesel generator — the current and most refined version of Caterpillar's 3400 Series V12 platform. Where the original 3412 established the platform's reputation for durability in the 700-750 kW class, the 3412C lifts the ceiling to 800 kW standby with improved controls, better fuel efficiency at partial load, and the EMCP 4 controller series that brings modern data logging and remote monitoring to the 3400 Series.

The 3400 Series is a medium-displacement industrial line: 27.0 liters across 12 cylinders, producing power through displacement and proven mechanical engineering rather than high-boost forced induction. The result is an engine that has accumulated decades of field hours in data centers, hospitals, and campus installations with a well-understood maintenance profile.

The C revision: what changed#

The "C" suffix in the 3412C marks meaningful upgrades over earlier production runs:

  • EMCP 4 controls: The EMCP 4 series replaces older analog panels with a digital controller supporting paralleling, load demand management, and Ethernet-based remote monitoring
  • Power rating: 800 kW standby is higher than earlier 3412 variants — the C calibration extracts more from the same displacement
  • Fuel efficiency: Revised injection calibration improves part-load fuel consumption, which matters for standby units that spend most of their life at 50-75% load during testing
  • Emissions: Tier 2 certification with improved combustion calibration

For operators with existing 3412 installations, the 3412C represents a compatible upgrade path with high core parts interchangeability and the same service tooling.

Our service perspective#

The 3412C's V12 configuration means 12 cylinders, 12 fuel injectors, and two turbocharger banks to keep in balance. Cylinder balance testing during major service intervals is important — uneven fuel delivery across the bank produces hot spots and accelerates wear asymmetrically. The EMCP 4 controller's data logging makes this easier than on older analog-panel units: exhaust temperature per-cylinder and per-bank boost pressure are visible in the controller history.

We find the 3412C particularly common in hospital installations that were built in the 1990s and early 2000s around the 3400 Series platform.

Engineering specifications

Physical

Length
170 in
Width
68 in
Height
86 in
Wet weight
13,800 lb

Fuel system & runtime

Fuel use @ full load
54 GPH
Fuel use @ 75% load
41 GPH

Documents & downloads

Spec sheets & manuals

Units For Sale

View all (2)
Used

2000

583 hrs

$99,500

Houston, TX

Used

1990

3,892 hrs

$39,900

Houston, TX

Don't see the right unit? Request a Custom Quote →

Ready to order this model?

Configure your Cat 3412C

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Cat 3412C

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

4.8 hours(0.2 days)

Fuel consumption ≈ 41.66 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Cat 3412C, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What is the difference between the Cat 3412 and 3412C?
The 3412C is the current-generation version of the 3412 platform. Key improvements in the C revision include the EMCP 4 series controller (replacing older analog/EMCP 2 controls), recalibrated fuel injection for improved part-load efficiency, and a higher power rating — 800 kW standby vs the base 3412's lower rating. The 3412C also benefits from accumulated field improvements to gaskets, seals, and ancillary systems. Parts compatibility between the 3412 and 3412C is high for the core engine, though controls wiring differs.
How does the 3412C compare to the Cat C27?
The 3412C (27.0L V12, 800 kW standby) and C27 (27.0L V12, 800 kW standby) are close in displacement and output, but come from different eras of Cat engineering. The C27 is from Cat's modern C-Series with ACERT technology and electronic fuel management. New installations typically specify the C27 for its electronic diagnostics; existing 3400 Series sites often prefer the 3412C for fleet continuity.
Is the 3412C still in production?
The 3412C has been in the Cat lineup for many years and remains available for new installations and as a replacement for existing 3412-series sites. For new data center and hospital projects, Cat's C27 and C32 represent the current-generation equivalent. However, the 3412C's robust parts availability and extensive installed base make it a solid specification for sites that prioritize long-term service support and parts commonality with existing equipment.

Compatible equipment

Similar models

Caterpillar Caterpillar 3412 720 kW liquid-cooled standby generator

Caterpillar

Caterpillar 3412

Diesel generator set built on the Cat 3412C V12 engine, rated 680 to 900 kVA at 50 Hz.

720 kW standby · Diesel · Liquid-cooled

The Caterpillar 3412C is a 680-900 kVA diesel generator built on the 27.02L V12 engine. ADEM A5 governor. Fuel: 45.3 gal/hr at 100% load (648 ekW prime, 50 Hz). Legacy platform for hospitals, campuses, and industrial sites.

3-phasehospital-largeindustrial
Caterpillar Cat C27 800 kW liquid-cooled standby generator

Caterpillar

Cat C27

800 kW diesel with CAT C27 V-12.

800 kW standby · Diesel · Liquid-cooled

680-800 kW diesel generator set with Cat C27 ACERT V-12 engine. Tier 2, MEUI fuel system, EMCP 4 controller.

Tier 23-phasecommercial-standbyindustrial
Caterpillar Cat D800 GC 800 kW liquid-cooled standby generator

Caterpillar

Cat D800 GC

800 kW Cat diesel with C27 V-12. Mission-critical power in GC package. Dual turbo reliability.

800 kW standby · Diesel · Liquid-cooled

800 kW diesel standby generator from Cat's GC value-engineered line. C27 V-12 engine with simplified controls for mission-critical standby.

Tier 23-phasestandbydata-center

Services for the Cat 3412C

Need service or parts for the Cat 3412C?

We service every major OEM and stock genuine parts for the most common models.