Blue Star Power Systems · PSI Small Gaseous (20-100 kW)

Blue Star GM60-02P

Standby: see spec sheet / 55 kW prime · Natural Gas / LPG · Liquid-cooled

55 kW prime natural gas / LP generator from Blue Star Power Systems. PSI 5.7L eight-cylinder V8 with catalyst/silencer, UCI224E alternator, DCP7310 controller, 208-600V output.

Blue Star Power Systems Blue Star GM60-02P generator — specifications and details
Standby power
See spec sheet / 55 kW prime
Voltage options
120/240V, 120/208V, 240V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 1/3-phase
Engine
PSI 5.7L NA · 5.7L
Alternator
UCI224E

Overview#

The Blue Star GM60-02P is a 55-kilowatt prime natural gas and LP generator powered by the PSI 5.7L NA — an eight-cylinder V8 naturally aspirated engine from Power Solutions International, configured for continuous prime power service. The "-P" designation identifies this as a prime-rated model with Catalyst/Silencer Mounted, 105°C temperature rise, and a 1-year / 1,500-hour prime warranty.

Blue Star Power Systems pairs the 5.7L engine with a UCI224E alternator and DCP7310 controller. The OPU footprint is 80 × 42 × 64 in at 2,025 lbs. Level 1 through Level 3 enclosures are available.

Prime Rating: Size to 55 kWe for Continuous Operation#

For any application involving continuous or unlimited-hours operation — base load, peak shaving, prime power in isolated sites — the 55 kWe prime rating governs.

Catalyst/Silencer Exhaust Aftertreatment#

Exhaust: Catalyst/Silencer Mounted. Confirm the OPU footprint and the exhaust connection dimensions before installation.

When to specify the GM60-02P#

  • Continuous prime power at 55 kWe on natural gas or LP (base load, off-grid, backup with frequent cycling)
  • Sites where the 80 × 42 in OPU width can be accommodated

Our service experience#

Prime-duty gaseous generators accumulate hours continuously and require disciplined PM intervals. The PSI 5.7L at 55 kWe prime is a reliable platform when maintained properly: catalyst inspection, spark plug replacement at OEM intervals, coolant condition, fuel pressure verification at full load (709 ft³/hr NG at 11.0 in. W.C.), and air filter maintenance. The OPU's 64-inch height with the catalyst assembly requires clearance planning above the unit — confirm overhead clearance at the installation site before delivery.

Engineering specifications

Physical

Length
80 in
Width
42 in
Height
64 in
Dry weight
2,025 lb

Acoustic

Sound @ 7m, full load
79 dBA
Enclosure
Open

Fuel system & runtime

NG required pressure
11 in WC

Thermal & ventilation

Heat to coolant
187,200 BTU/hr
Heat radiated
44,040 BTU/hr
Exhaust flow
553 CFM
Exhaust temp
1350 °F
Combustion air
173 CFM
Ventilation air
7,400 CFM

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Blue Star GM60-02P

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Blue Star GM60-02P

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Fuel demand at 75% load

577,500 BTU/hr≈ 577.5 cf/min @ 1,000 BTU/cf

On utility natural gas the runtime is generally unlimited provided the supply line and meter can deliver this BTU/hr at the engine's required inlet pressure (typically 5–14" WC residential, up to 5 psi commercial). Confirm against the OEM's published fuel-pressure spec.

Frequently Asked Questions

What is the catalyst/silencer on the GM60-02P and what maintenance does it require?
Catalyst/Silencer Mounted. The catalyst requires periodic inspection and replacement at PSI-specified intervals — typically monitored by operating hours and exhaust back-pressure measurement.
What are the fuel consumption rates for the GM60-02P at prime output?
At 100% prime load (55 kWe), the GM60-02P consumes 709 ft³/hr of natural gas or 311 ft³/hr of LP. At 75% prime load: 608 ft³/hr NG or 236 ft³/hr LP. At 50% prime load: 502 ft³/hr NG or 196 ft³/hr LP. Required inlet pressure is 11.0 in. W.C. Heat rejected to coolant at full prime load is 3,120 BTU/min; heat radiated to the room is 734 BTU/min. Combustion air is 173 CFM; ventilation requirement is 7,400 CFM.

Compatible equipment

More in the PSI Small Gaseous (20-100 kW)

20–100 kW natural gas and LP standby on PSI inline-four, V6, and V8 platforms — single and three-phase.

Similar models

Blue Star Power Systems Blue Star GM60-02 60 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star GM60-02

60 kW standby · Natural Gas / LPG · Liquid-cooled

60 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 5.7L eight-cylinder naturally aspirated V8 engine, UCI224E alternator, DCP7310 controller, 208-600V output.

3-phasecommerciallight-commercial
Blue Star Power Systems Blue Star GM50-03 50 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star GM50-03

50 kW standby · Natural Gas / LPG · Liquid-cooled

50 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 5.7L eight-cylinder naturally aspirated V8 engine, UCI224D alternator, DCP7310 controller, 208-600V output.

3-phasecommerciallight-commercial
Blue Star Power Systems Blue Star GM100-03 100 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star GM100-03

100 kW standby · Natural Gas / LPG · Liquid-cooled

100 kW natural gas standby generator (80 kW on LP) from Blue Star Power Systems. PSI 5.7LTCAC turbocharged charge-air-cooled V8, UCI274C alternator, DCP7310 controller, 208-600V output.

3-phasecommercialmedium-commercial

Services for the Blue Star GM60-02P

Need service or parts for the Blue Star GM60-02P?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: