The Eaton ATC-900 is a commercial automatic transfer switch covering 40-1200A — competing directly with the ASCO 7000 Series in the mid-range commercial market. It distinguishes itself with a unique circuit-breaker-based option, integrated maintenance management, and a competitive price point within the broader Eaton electrical ecosystem.
We encounter Eaton ATS primarily in facilities with existing Eaton switchgear (the ecosystem play). The ATC-900 controller is well-designed with clear status indication and straightforward maintenance. Transfer mechanism service is similar to ASCO — contact inspection, mechanism lubrication, and control verification during annual PM.
Frequently Asked Questions
How does the Eaton ATC-900 compare to ASCO 7000?
The ASCO 7000 has a broader amperage range (30-4000A vs 40-1200A) and larger market share. The Eaton ATC-900 offers a unique circuit-breaker-based option (not available from ASCO), integrated maintenance management, and is typically 10-15% less expensive at equivalent amperage. Choose Eaton when you already have Eaton switchgear or need the circuit-breaker variant.
What is the circuit-breaker ATS option?
Unlike contactor-based switches (ASCO's approach), Eaton offers ATS built around circuit breakers. This provides inherent overcurrent protection within the transfer switch itself — eliminating the need for separate upstream protective devices in some configurations.
What communications does the ATC-900 support?
Modbus RTU/TCP, BACnet, and SNMP. The controller also provides proactive condition reporting — alerting when maintenance is due based on transfer count and elapsed time, not just runtime.
When should I choose Eaton over ASCO?
Choose Eaton when: (a) you need circuit-breaker-based ATS, (b) the facility already uses Eaton switchgear ecosystem, (c) budget is a factor (typically less expensive), or (d) the proactive maintenance features add value. Choose ASCO when: you need >1200A, bypass/isolation, or the broadest accessory catalog.
Found in these gensets
Generator models that ship with or are commonly paired with the Eaton ATC-900.
B
Blue Star Power Systems
New
Blue Star VD125-02FT4
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby generator from Blue Star Power Systems. Volvo Penta TAD572VE engine with charge-air cooling, paired with Basler DGC-2020 controller.
Tier 4 Final3-phasecommerciallight-industrial
B
Blue Star Power Systems
New
Blue Star VD150-04FT4
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD881VE 7.7L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD200-04FT4
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1180VE 10.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD230-01
230 kW standby · Diesel · Liquid-cooled
230 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD851GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD250-03
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD852GE 7.7L inline-six, DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD250-04FT4
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1381VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD275-01
275 kW standby · Diesel · Liquid-cooled
275 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD853GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD300-01
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1351GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD300-02FT4
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel standby generator. Volvo Penta TAD1373VE 12.8L inline-six, 208-600V output, with Basler DGC-2020 controller and SCR aftertreatment.
300 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1383VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
350 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1352GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD400-01
400 kW standby · Diesel · Liquid-cooled
400 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1353GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD450-01
450 kW standby · Diesel · Liquid-cooled
450 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1650GE 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD500-01
500 kW standby · Diesel · Liquid-cooled
500 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1641GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD550-01
550 kW standby · Diesel · Liquid-cooled
550 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1642GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD600-01
600 kW standby · Diesel · Liquid-cooled
600 kW EPA Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1643GE 16.1L inline-six, 208-4160V output, available with medium-voltage option.
Tier 23-phaselarge-commercialhospital
B
Blue Star Power Systems
New
Blue Star VD600-03
600 kW standby · Diesel · Liquid-cooled
600 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1644GE 16.1L inline-six with dual-stage turbo, DSE DCP7310 controller, 208-600V.
Tier 23-phasecommerciallarge-commercial
B
Blue Star Power Systems
New
Blue Star VD700-01
700 kW standby · Diesel · Liquid-cooled
700 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1744GE 17.3L inline-six with Common Rail injection, DSE DCP7310 controller, 208-600V.
Tier 23-phaselarge-commercialhospital
Need service for the Eaton ATC-900?
Our technicians work on every major component OEM. We stock common parts and source rare ones.