Commercial automatic transfer switch. 100-400A, three-phase, open transition, contactor switching, TSC 9 controller. UL 1008 listed for emergency systems.
The Thomson TS920 is the commercial counterpart to the residential TS910, offering contactor-based automatic transfer switching in the 100-400A range for commercial standby and emergency power applications. The critical distinction from the TS910 is the UL listing: the TS920 is UL 1008 listed for legally required emergency systems (NEC Articles 700/701), while the TS910 covers only optional standby (NEC 702). Both models are available in single and three-phase configurations. A service-entrance rated variant (TS920SE) is also available.
The TS920 uses the TSC 9 microprocessor controller with commercial-specific features for voltage sensing, programmable timers, and exercise scheduling. The three-phase 400A unit measures 45.1" x 24.9" x 11" and weighs 90 pounds in the standard NEMA 1 indoor enclosure. Both NEMA 1 indoor and NEMA 3R outdoor enclosures are available.
The TS920 bridges the gap between residential (TS910) and industrial (TS970) in Thomson's contactor-based ATS range:
TS910 (100-400A, 1 or 3-phase): residential whole-house generators
TS920 (100-400A, 3-phase): small commercial buildings, restaurants, retail, multi-family common loads
TS970 (100-1200A, 3-phase): larger commercial and industrial, BMS integration via Modbus
For commercial loads under 400A that don't need Modbus or advanced controller features, the TS920 is the cost-effective choice. For loads above 400A or facilities requiring building automation integration, step up to the TS970.
We see the Thomson TS920 most commonly in small Bay Area commercial installations — restaurants, small office buildings, and retail spaces in the 200-400A range. The contactor mechanism provides fast, reliable transfers, and the TSC 9 controller is straightforward to configure.
The 400A three-phase frame at 45.1" x 24.9" x 11" is compact enough for standard electrical rooms in commercial tenant improvements. At 90 pounds, it's light enough for a two-person install without mechanical handling equipment — a practical advantage over mechanically-held alternatives in tight retrofit spaces.
Frequently Asked Questions
What is the difference between the Thomson TS910 and TS920?
Both use the TSC 9 controller and contactor-based switching in 100-400A. While both are available in single and three-phase configurations, the critical difference is the UL listing scope: the TS910 is UL 1008 listed for optional standby systems (NEC Article 702), while the TS920 is UL 1008 listed for legally required emergency systems (NEC Articles 700/701). The TS920 also has higher three-phase withstand ratings. If the authority having jurisdiction requires emergency-system listing, you must specify the TS920.
What amperage ratings are available for the TS920?
The TS920 is available in 100A, 200A, and 400A ratings for commercial standby applications. All ratings carry 100% continuous current capacity and support both copper and aluminum power cable connections.
Does the TS920 support three-phase power?
Yes. The TS920 is a three-phase (3-pole) transfer switch available at 120/208V or 120/240V with 4-wire neutral. This makes it suitable for small commercial buildings with three-phase electrical service. For single-phase residential applications, use the TS910 instead.
What are the physical dimensions of the TS920?
The three-phase 400A unit measures 45.1 inches high by 24.9 inches wide by 11 inches deep and weighs 90 pounds in the standard NEMA 1 indoor enclosure. A NEMA 3R outdoor enclosure is also available. The rust-resistant aluminum enclosure is powder coated.
When should I choose the TS920 over the TS970?
The TS920 covers 100-400A with the simpler TSC 9 controller and is positioned for small commercial buildings. The TS970 covers 100-1200A with the TSC 900 controller (7-inch color touchscreen, Modbus, programmable I/O) and targets larger commercial and industrial applications. If you need more than 400A or require building management system integration via Modbus, specify the TS970.
Key Terms
Contactor switching
Electromagnetic switching mechanism that uses a coil to snap contacts closed. Fast transfer speed, compact size, and lower cost compared to mechanically-held designs.
Open-transition transfer
A brief (100-500ms) interruption between disconnecting from one source and connecting to the other. Standard for commercial backup applications.
4-wire with neutral
The TS920 three-phase configuration includes a solid (unswitched) neutral bus for 4-wire systems. The switched poles carry the phase conductors; neutral passes through on a dedicated bus.
Found in these gensets
Generator models that ship with or are commonly paired with the Thomson TS920 Automatic Transfer Switch.
Blue Star Power Systems
Blue Star GM100-03
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby for commercial, school, and multi-family buildings where gas-fueled backup and component independence matter.
100 kW natural gas standby generator (80 kW on LP) from Blue Star Power Systems. PSI 5.7LTCAC turbocharged charge-air-cooled V8, UCI274C alternator, DCP7310 controller, 208-600V output.
3-phasecommercialmedium-commercial
Blue Star Power Systems
Blue Star GM50-03
50 kW standby · Natural Gas / LPG · Liquid-cooled
50 kW natural gas standby for light commercial, retail, and small office buildings where gas-fueled backup and component independence matter.
50 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 5.7L eight-cylinder naturally aspirated V8 engine, UCI224D alternator, DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star GM60-02
60 kW standby · Natural Gas / LPG · Liquid-cooled
60 kW natural gas standby for light commercial, retail, and small facilities where gas-fueled backup and component independence matter.
60 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 5.7L eight-cylinder naturally aspirated V8 engine, UCI224E alternator, DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star GM60-02P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
55 kW prime natural gas for continuous-duty commercial applications, cogeneration sites, and facilities needing 24/7 gas-fueled power.
55 kW prime natural gas / LP generator from Blue Star Power Systems. PSI 5.7L eight-cylinder V8 with catalyst/silencer, UCI224E alternator, DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star JD100-01
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, multi-family, and municipal facilities where value engineering and service-tech independence matter.
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine, UCI274 alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD150-01
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and component independence matter.
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HF285 6-cylinder engine, UCI274/UCDI274 alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD200-01
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for value-engineering projects, municipal facilities, and service-savvy buyers who prioritize component independence.
200 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HFG85 6-cylinder engine, S4L1S/UCDI274 alternator, DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD250-02
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for commercial, institutional, and campus facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HF484 9.0L engine, S4L1S/S4L1D alternator, DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD40-03
40 kW standby · Diesel · Liquid-cooled
40 kW diesel standby for small commercial, retail, and light-duty facilities where component independence and value engineering matter.
40 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045TF280 engine, UCI224 alternator, DCP7310 controller.
Tier 33-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD40-05FT4
40 kW standby · Diesel · Liquid-cooled
40 kW Tier 4 Final diesel standby for small commercial and light-duty facilities requiring current emissions compliance.
40 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 3029HG530 2.9L inline-three with DOC/DPF, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star JD40-05FT4MP
40 kW standby · Diesel · Liquid-cooled
40 kW Tier 4 Final mobile diesel for construction sites, emergency response, and temporary power where portability and clean emissions matter.
40 kW Tier 4 Final mobile trailer diesel generator built by Blue Star Power Systems. John Deere 3029HG530 three-cylinder engine, UCI224D alternator, DCP7310 controller, 130-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star JD50-03
50 kW standby · Diesel · Liquid-cooled
50 kW diesel standby for small commercial, retail, worship, and light-industrial sites prioritizing component independence over brand premium.
50 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045TF280 engine, UCI224 alternator, DCP7310 controller.
Tier 33-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD60-02
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for light commercial, retail, multi-family, and telecom sites where value engineering and open-source components matter.
60 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045TF280 engine, UCI224 alternator, DCP7310 controller.
Tier 33-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD60-04FT4
60 kW standby · Diesel · Liquid-cooled
60 kW Tier 4 Final diesel standby for commercial and light-industrial facilities requiring current emissions compliance and component independence.
60 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 4045HFG04 4.5L inline-four with SCR/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star JD60-04FT4MP
60 kW standby · Diesel · Liquid-cooled
60 kW Tier 4 Final mobile diesel for construction sites, emergency response, and temporary power where portability and clean emissions matter.
60 kW Tier 4 Final mobile trailer diesel generator built by Blue Star Power Systems. John Deere 4045HFG04 four-cylinder engine, UCI224F alternator, DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star JD80-02
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial, multi-family, and municipal facilities where value engineering and service-tech independence matter.
80 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine with charge air cooling, UCI274/UCI224 alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD80-03FT4
80 kW standby · Diesel · Liquid-cooled
80 kW Tier 4 Final diesel standby for commercial, multi-family, and institutional facilities requiring current emissions and component independence.
80 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 4045HFG04 4.5L inline-four with SCR/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star JD80-03FT4MP
80 kW standby · Diesel · Liquid-cooled
80 kW Tier 4 Final mobile diesel for construction, emergency response, and planned outage support where portability and clean emissions matter.
80 kW Tier 4 Final mobile trailer diesel generator built by Blue Star Power Systems. John Deere 4045HFG04 four-cylinder engine, UCI274C alternator, DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star NG150-01
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas standby for commercial, institutional, and campus buildings where gas-fueled backup and component independence matter.
150 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.1LT turbocharged inline-six, DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star NG150-01P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
125 kW prime natural gas for continuous-duty commercial and institutional applications needing 24/7 gas-fueled power with component independence.
125 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 8.1LT inline-six, DCP7310 controller, 208-600V, continuous prime duty.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star NG200-01
200 kW standby · Natural Gas / LPG · Liquid-cooled
200 kW natural gas standby for commercial, institutional, and campus buildings where gas-fueled backup and component independence matter.
200 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 11.1L turbocharged inline-six, DCP7310 controller, 208-600V output.
3-phasecommercialmedium-commercial
Blue Star Power Systems
Blue Star NG200-01P
200 kW standby · Natural Gas / LPG · Liquid-cooled
175 kW prime natural gas for continuous-duty commercial and institutional applications needing 24/7 gas-fueled power with component independence.
175 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 11.1L inline-six, DCP7310 controller, 208-600V, continuous prime duty.
3-phasecommercialmedium-commercial
Blue Star Power Systems
Blue Star PD100-01
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, institutional, and municipal facilities where Perkins parts access and non-proprietary components matter.
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, UCI274C alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD125-01
125 kW standby · Diesel · Liquid-cooled
125 kW diesel standby for commercial, institutional, and municipal facilities where Perkins parts access and component independence matter.
125 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, UCI274E alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD150-01
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and Perkins global parts access matter.
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, UCI274F alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD180-01
180 kW standby · Diesel · Liquid-cooled
180 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and Perkins global parts access matter.
180 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG4 six-cylinder engine with charge air cooling, UCI274G alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD200-01
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for value-engineering projects, municipal facilities, and service-savvy buyers who prioritize component independence.
200 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG5 six-cylinder engine with charge air cooling, UCI274H alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD250-01
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1706D-E93TAG1 six-cylinder engine with charge air cooling, S4L1D-C41 alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD50-01
50 kW standby · Diesel · Liquid-cooled
50 kW diesel standby for small commercial, worship, and light-industrial sites prioritizing Perkins global parts availability and value engineering.
50 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-44TG1 turbocharged engine, UCI224D alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD60-01
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for light commercial, retail, and multi-family sites where Perkins global parts network and component independence matter.
60 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TG1 turbocharged engine, UCI224E alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD80-01
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial, multi-family, and municipal sites where Perkins global parts availability and value engineering matter.
80 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, UCI224G alternator, DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PS130-01
130 kW standby · Natural Gas / LPG · Liquid-cooled
130 kW natural gas standby for commercial, school, and multi-family buildings where gas-fueled backup and component independence matter.
130 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.8LTCAC turbocharged V8, DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star PS150-01
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas standby for commercial, school, and institutional buildings where gas-fueled backup and component independence matter.
150 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.8LTCAC turbocharged-aftercooled V8, DCP7310 controller, single- and three-phase 120-600V.
3-phaselarge-commercialschool-campus
Blue Star Power Systems
Blue Star PS40-01
40 kW standby · Natural Gas / LPG · Liquid-cooled
40 kW natural gas standby for light commercial, retail, and small facilities where gas-fueled backup and component independence matter.
40 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 4.3L six-cylinder naturally aspirated V6 engine, UCI224C alternator, DSE DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star PS40-01P
40 kW standby · Natural Gas / LPG · Liquid-cooled
35 kW prime natural gas for continuous-duty commercial applications and facilities needing 24/7 gas-fueled power with component independence.
35 kW prime natural gas / LP generator from Blue Star Power Systems. PSI 4.3L six-cylinder V6 engine with catalyst/silencer, UCI224C alternator, DSE DCP7310 controller, 208-600V output.
3-phasecommerciallight-commercial
Blue Star Power Systems
Blue Star VD100-04FT4
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
100 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD581VE 5.13L inline-four with SCR/DPF/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star VD100-04FT4MP
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final mobile diesel for construction, emergency response, and temporary power where portability and clean emissions matter.
100 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD581VE four-cylinder engine, UCI274D alternator, DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD125-04FT4
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
125 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD582VE 5.13L inline-four with SCR/DPF/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star VD125-04FT4MP
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final mobile diesel for construction, emergency response, and temporary power where portability and clean emissions matter.
125 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD582VE four-cylinder engine, UCI274E alternator, DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD150-04FT4
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel standby for commercial, institutional, and municipal facilities requiring current emissions and component independence.
150 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD881VE 7.7L inline-six with SCR/DPF/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD150-04FT4MP
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final mobile diesel for construction, planned outage support, and temporary power requiring portability and clean emissions.
150 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD881VE six-cylinder engine, UCI274F alternator, DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD200-04FT4
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel standby for commercial, institutional, and campus facilities requiring current emissions and component independence.
200 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1180VE 10.8L inline-six with SCR/DPF/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD200-04FT4MP
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final mobile diesel for construction, planned outage support, and temporary power requiring portability and clean emissions.
200 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1180VE six-cylinder engine, UCDI274J1 alternator, DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD230-01
230 kW standby · Diesel · Liquid-cooled
230 kW diesel standby for commercial, institutional, and campus facilities where value engineering and non-proprietary component access matter.
230 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD851GE 7.7L inline-six with DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-03
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for large commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD852GE 7.7L inline-six, DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-04FT4
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel standby for commercial, campus, and institutional facilities requiring current emissions and component independence.
250 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1381VE 12.8L inline-six with SCR/DPF/DOC, DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-04FT4MP
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final mobile diesel for construction, planned outage support, and large-scale temporary power with clean emissions.
250 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1381VE six-cylinder engine, S4L1D-D41 alternator, DCP7310 controller, 350-gallon integrated fuel tank.
80 kW diesel standby for mid-size commercial, assisted living, and schools with CAT fleet.
80 kW diesel standby generator with Cat C4.4 turbocharged inline-4 engine. Reliable platform for commercial standby and prime power applications.
3-phasecommercial-standbyprime-power
Caterpillar
Cat DG200
200 kW natural gas with CAT DG200. No diesel storage needed. EPA certified for non-emergency application.
200 kW standby · Natural Gas / LPG · Liquid-cooled
200 kW natural gas standby/DR for commercial buildings, hospitals, and facilities on gas mains.
200 kW natural gas generator with 10.3L V8 engine. Emergency standby, demand response, and prime power for commercial and industrial applications.
3-phasecommercial-standbydemand-response
Caterpillar
Caterpillar C7
200 kW diesel with CAT C7 ACERT inline-6. Best resale value in class. ~200 US dealers. Compact footprint.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for retail, telecom, and small commercial with CAT fleet standardization.
The Caterpillar C7.1 ACERT is a 200 kW standby diesel generator with EPA Tier 3 certification. 7.01L inline-6 with MEUI fuel injection. Compact standby power for small commercial and retail applications.
Tier 33-phasecommercial-standbyretail
Caterpillar
Caterpillar C9
250 kW diesel with CAT C9 ACERT inline-6. Best resale. ~200 US dealers.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for mid-size commercial, schools, and light-industrial with CAT fleet.
The Caterpillar C9 ACERT is a 250 kW standby diesel generator with EPA Tier 3 emissions certification. 8.8L inline-6 with MEUI fuel injection. Ideal for retail, telecom, and light-industrial standby applications.
Tier 33-phasecommercial-standbyretail
Cummins
Cummins C100 D6
100 kW diesel from Cummins' fully integrated QSB5 series. Accepts full rated load in a single step per NFPA 110 for Level 1 systems.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for office complexes, hotels, and commercial buildings requiring fast load pickup.
100 kW standby / 90 kW prime EPA Tier 3 diesel generator set at 60 Hz with the Cummins QSB5-G13 engine. Accepts full rated load in a single step per NFPA 110 for Level 1 systems; available listed to UL 2200.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C100 N6
100 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel logistics.
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby for hotels, office campuses, and healthcare clinics with gas service.
100 kW natural gas standby generator with QSJ5.9G-G3 engine. 100 kW / 125 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified. Dry weight 2812 lbs.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1000 N6b
1000 kW natural gas standby powered by the QSK60G. NFPA 110 Type 10 capable for mission-critical facilities without diesel infrastructure.
1 MW standby · Natural Gas / LPG · Liquid-cooled
1000 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and mission-critical facilities requiring NFPA 110 Type 10 compliance.
1000 kW natural gas standby generator with QSK60G engine. 1000 kW / 1250 kVA standby, NFPA 110 Type 10 capable, PowerCommand controls, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C110 D6
112 kW diesel on the Cummins 6BT5.9-G6 platform. Reliable commercial standby power with full Cummins vertical integration.
112 kW standby · Diesel · Liquid-cooled
112 kW diesel standby for commercial buildings and light-industrial facilities requiring mid-range emergency power between the C100 and C125.
112 kW diesel standby generator with Cummins 6BT5.9-G6 engine and PowerCommand control. Liquid-cooled, for commercial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C1100 N6
1100 kW natural gas standby powered by the QSK60G. High-output megawatt-class gas power without diesel fuel infrastructure.
1.1 MW standby · Natural Gas / LPG · Liquid-cooled
1100 kW natural gas standby for hospitals, data centers, large campuses, and industrial facilities with natural gas service.
1100 kW natural gas standby generator with QSK60G gas engine. 1100 kW / 1375 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C125 D6
125 kW diesel with Cummins QSB5-G6 engine. Accepts full rated load in a single step per NFPA 110 Level 1.
125 kW standby · Diesel · Liquid-cooled
125 kW diesel standby for hotels, office complexes, and commercial buildings, powered by a 4-cylinder QSB5-G6 engine.
125 kW EPA Tier 3 diesel standby generator with Cummins QSB5-G6 engine and PowerCommand 1.1 control. Available UL 2200 listed; accepts full rated load in a single step per NFPA 110 Level 1.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C125 N6
125 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Single-source warranty.
125 kW standby · Natural Gas · Liquid-cooled
125 kW natural gas standby for mid-size commercial, schools, and healthcare facilities on gas mains.
125 kW natural gas standby generator with QSJ8.9G engine. 125 kW standby, PowerCommand 2.3 controls, UL 2200, IBC Seismic, NFPA 110 capable. Quiet Connect RS125 series, weight 3915 lbs.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1250 N6
1250 kW natural gas standby powered by the QSV91G. High-capacity gas power for mission-critical facilities without diesel infrastructure.
1.3 MW standby · Natural Gas / LPG · Liquid-cooled
1250 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and industrial facilities with natural gas service.
1250 kW natural gas standby generator with QSV91G gas engine. 1250 kW / 1563 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1300 N6
1300 kW natural gas standby powered by the QSK60G. NFPA 110 Type 10 capable for mission-critical facilities at the top of QSK60G output range.
1.3 MW standby · Natural Gas / LPG · Liquid-cooled
1300 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and mission-critical facilities requiring NFPA 110 Type 10 compliance.
1300 kW natural gas standby generator with QSK60G engine. 1300 kW / 1625 kVA standby, NFPA 110 Type 10 capable, PowerCommand controls, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1400 N6c
1400 kW natural gas standby powered by the QSV91G. High-capacity megawatt-class gas power for mission-critical facilities.
1.4 MW standby · Natural Gas / LPG · Liquid-cooled
1400 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and industrial facilities with natural gas service.
1400 kW natural gas standby generator with QSV91G gas engine. 1400 kW / 1750 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C150 D6
150 kW standby diesel generator set with the Cummins QSB7-G5 engine and EPA Tier 3 emissions certification.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hotels, warehouses, and mid-size commercial buildings.
150 kW standby, 135 kW prime 60 Hz diesel generator set with the Cummins QSB7-G5 engine, EPA Tier 3 emissions certification and PC 1.1 as the standard controller.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C150 N6
150 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel permitting needed.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas standby for hotels, large retail, and commercial campuses with gas service.
150 kW natural gas/propane standby generator with Cummins QSJ8.9G 8.9L turbocharged inline-6 engine. PowerCommand control, UL 2200 listed, NFPA 110 Level 1 capable. Wet weight 1,776 kg (3,915 lbs).
1540 kW natural gas standby powered by the QSV91G at its top-end gas rating. Maximum QSV91G output without diesel infrastructure.
1.5 MW standby · Natural Gas / LPG · Liquid-cooled
1540 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and industrial facilities with natural gas service.
1540 kW natural gas standby generator with QSV91G gas engine. 1540 kW / 1925 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C175 D6
175 kW standby diesel with the Cummins QSB7-G5 in-line 6-cylinder engine, EPA Tier 3, with PC 1.1 as the standard controller.
175 kW standby · Diesel · Liquid-cooled
175 kW diesel standby for hotels, office complexes, and mid-size commercial buildings requiring substantial emergency power capacity.
175 kW EPA Tier 3 diesel standby generator with the Cummins QSB7-G5 in-line 6-cylinder engine and PC 1.1 as the standard controller. A sound enclosure is offered.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C175 N6
175 kW natural gas standby with a Cummins GTA 8.3 engine and PowerCommand 1.1 control. No diesel fuel storage infrastructure.
175 kW standby · Natural Gas · Liquid-cooled
175 kW natural gas standby for schools, mid-size hotels, and commercial campuses on gas mains.
175 kW natural gas standby generator with GTA 8.3G engine. 175 kW / 219 kVA standby, PowerCommand 1.1 controls, 2202 CFH full-load, dimensions 115 x 40 x 59 in. ISO 9001:2015 manufactured.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1750 N6cb
1750 kW natural gas standby powered by the HSK78G. Near-2-MW gas power for mission-critical facilities without diesel infrastructure.
1.8 MW standby · Natural Gas / LPG · Liquid-cooled
1750 kW natural gas standby for large hospitals, hyperscale data centers, major campuses, and industrial facilities with utility-grade gas service.
1750 kW natural gas standby generator with HSK78G gas engine. 1750 kW / 2188 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C200 D6
200 kW standby diesel generator set with a Cummins QSB7-G5 engine. PC 1.1 controller standard.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, data centers, and large commercial facilities.
200 kW standby (180 kW prime) 60 Hz diesel generator set with the Cummins QSB7-G5 engine, EPA Tier 3 emissions certification and the PC 1.1 standard controller.
Tier 33-phasecommercial-standbyindustrial
Cummins
Cummins C200 N6
200 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Power Command controller.
200 kW standby · Natural Gas / LPG · Liquid-cooled
200 kW natural gas standby for large commercial, healthcare, and office towers on gas mains.
200 kW natural gas/propane commercial standby generator. Cummins' flagship gaseous unit with QSJ8.9G engine and PowerCommand 2.3 controller.
2000 kW natural gas standby -- the largest gas generator in the Cummins lineup. Full 2 MW single-unit gas power for the most demanding mission-critical facilities.
2 MW standby · Natural Gas / LPG · Liquid-cooled
2000 kW natural gas standby for large hospitals, hyperscale data centers, major campuses, and heavy industrial facilities with utility-grade gas service.
2000 kW natural gas standby generator with HSK78G gas engine. 2000 kW / 2500 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified. Largest gas generator in the Cummins lineup.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C250 D6
250 kW diesel with the Cummins QSL9-G7 engine and Bosch HPCR fuel system.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, data centers, and large commercial buildings requiring substantial emergency power.
250 kW diesel standby generator with the EPA Tier 3 Cummins QSL9-G7 engine (8.8 L, in-line 6-cylinder) and Bosch high pressure common rail (HPCR) fuel system, for commercial and industrial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C250 N6
250 kW natural gas generator set that accepts full rated load in a single step per NFPA 110 Type 10 (ten seconds). No diesel logistics.
250 kW standby · Natural Gas · Liquid-cooled
250 kW natural gas standby for hospitals, multi-building campuses, and data centers on gas mains.
250 kW natural gas standby generator with Cummins GTA855E 14 L engine. PowerCommand 3.3 control, UL 2200 listed, NFPA 110 Type 10 Level 1/2 capable. EPA SI NSPS stationary emergency certified.
3-phaselarge-commercialhospital-medium
Cummins
Cummins C275 D6
275 kW standby diesel generator set with a Cummins QSL9-G9 engine, PCC 3300 control and EPA Tier 4 emissions certification.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for hospitals, data centers, and large commercial buildings requiring high-capacity emergency power.
275 kW standby, 250 kW prime diesel generator set at 60 Hz with a Cummins QSL9-G9 engine, PCC 3300 control and EPA Tier 4 emissions certification, for commercial and industrial standby applications.
3-phasecommercial-standbylight-industrial
Cummins
Cummins C300 D6
300 kW standby diesel with the Cummins QSL9-G7 engine: Bosch high-pressure common rail fuel system, Holset HX40 wastegated turbo, EPA Tier 3.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, data centers, and large commercial facilities.
300 kW EPA Tier 3 diesel standby generator with the Cummins QSL9-G7 inline-6 engine and Bosch HPCR fuel system, for large commercial and industrial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C350 N6
350 kW natural gas standby with Cummins vertical integration. Mid-range gas power without diesel logistics.
350 kW standby · Natural Gas / LPG · Liquid-cooled
350 kW natural gas standby for mid-size commercial buildings, hotels, and healthcare facilities with natural gas service.
350 kW natural gas standby generator. 350 kW / 438 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins
Cummins C55 D5
44 kW / 55 kVA standby and 40 kW / 50 kVA prime at 50 Hz, with the Cummins 4BTAA3.3-G13 engine, UCI224C alternator and PS0600 controller as standard.
44 kW standby · Diesel · Liquid-cooled
44 kW diesel standby for international 50 Hz commercial, retail, and light-industrial applications.
44 kW / 55 kVA standby (40 kW / 50 kVA prime) 50 Hz diesel generator set from Cummins' international model range, with the Cummins 4BTAA3.3-G13 engine, for commercial applications.
3-phasecommercial-standbyinternational-export
Cummins
Cummins C550 N6
550 kW natural gas standby powered by the GTA28 gas engine. Industrial-grade gas power without diesel logistics.
550 kW standby · Natural Gas / LPG · Liquid-cooled
550 kW natural gas standby for large commercial buildings, hospitals, data centers, and industrial facilities with natural gas service.
550 kW natural gas standby generator with GTA28 gas engine. 550 kW / 688 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C60 N6
60 kW natural gas with full Cummins vertical integration. QuietConnect-class sound levels. No diesel storage needed.
60 kW standby · Natural Gas / LPG · Liquid-cooled
60 kW natural gas standby for restaurants, small offices, and commercial buildings on gas mains.
600 kW natural gas standby powered by the GTA38 gas engine. Industrial-grade gas power without diesel fuel infrastructure.
600 kW standby · Natural Gas / LPG · Liquid-cooled
600 kW natural gas standby for hospitals, data centers, large commercial buildings, and industrial facilities with natural gas service.
600 kW natural gas standby generator with GTA38 gas engine. 600 kW / 750 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C650 N6
650 kW natural gas standby powered by the GTA38 gas engine. Top-end GTA38 output without diesel fuel infrastructure.
650 kW standby · Natural Gas / LPG · Liquid-cooled
650 kW natural gas standby for hospitals, data centers, large commercial buildings, and industrial facilities with natural gas service.
650 kW natural gas standby generator with GTA38 gas engine. 650 kW / 813 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C80 D6
80 kW standby diesel generator set that accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems.
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial buildings, healthcare clinics, and municipal water systems.
80 kW standby, 72 kW prime EPA Tier 3 diesel generator set at 60 Hz with a Cummins QSB5-G13 engine and a standard cooling package for running at up to 50 °C (122 °F) ambient. Aluminum sound-attenuated enclosures available.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C80 N6
80 kW natural gas with full Cummins vertical integration. QuietConnect-class sound levels. No fuel storage permits.
80 kW standby · Natural Gas / LPG · Liquid-cooled
80 kW natural gas standby for mid-size commercial, assisted living, and retail with gas service.
80 kW natural gas standby generator with QSJ5.9G engine. PowerCommand 1.1 controls, UL 2200, IBC Seismic, NFPA 110 capable. Quiet Connect RS80 series in sound-attenuated aluminum enclosure.
3-phasecommercial-standbylight-commercial-standby
Cummins
Cummins C800 N6
800 kW natural gas standby powered by the GTA50 gas engine. High-capacity gas power without diesel fuel infrastructure.
800 kW standby · Natural Gas / LPG · Liquid-cooled
800 kW natural gas standby for hospitals, data centers, large commercial complexes, and industrial facilities with natural gas service.
800 kW natural gas standby generator with GTA50 gas engine. 800 kW / 1000 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins QSB7 (C200 D6)
200 kW diesel with QSB7 engine. Full Cummins vertical integration. 100% load in 10 seconds. Best cold-weather start (-40F).
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, office complexes, and commercial buildings in any climate.
200 kW diesel commercial standby generator with Cummins QSB7 6.7L engine. The mid-range diesel workhorse for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Generac
Generac SD050
50 kW industrial diesel with Generac 3.4L engine. Digital controller, NFPA 110 ready.
50 kW standby · Diesel · Liquid-cooled
50 kW diesel standby for restaurants, small grocery stores, and light-industrial facilities.
50 kW industrial diesel standby generator. Generac 3.4L turbocharged-aftercooled inline-4, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
130 kW industrial diesel with Iveco/FPT engine. Digital controller with paralleling capability.
130 kW standby · Diesel · Liquid-cooled
130 kW diesel standby for mid-size commercial, light manufacturing, and healthcare clinics.
130 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD150
150 kW industrial diesel with 10,000+ dealer support network. NFPA 110 compliant.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hotels, warehouses, and commercial office buildings.
150 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6 with electronic injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
175 kW diesel standby for large retail, assisted living, and mid-size industrial facilities.
175 kW industrial diesel standby generator. Generac 6.7L turbocharged-aftercooled inline-6 with electronic injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD200
200 kW industrial diesel with Iveco/FPT 8.7L engine. Paralleling-ready controller.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, data centers, and large commercial complexes.
250 kW industrial diesel. Proven Iveco/FPT engine. Largest US dealer network.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, manufacturing plants, and high-rise buildings.
250 kW industrial diesel standby generator. Iveco/FPT 8.7L turbocharged-aftercooled inline-6 with common rail injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SG040
40 kW natural gas/LP standby. No diesel storage or spill containment needed.
40 kW standby · Natural Gas · Liquid-cooled
40 kW natural gas standby for offices, restaurants, and small commercial with gas service.
50 kW natural gas/LP standby. No fuel storage permits needed.
50 kW standby · Natural Gas · Liquid-cooled
50 kW natural gas standby for grocery stores, medical offices, and chain retail with gas service.
50 kW standby natural gas generator with Generac 4.5L turbocharged spark-ignited engine. EPA certified stationary emergency. Single and three-phase configurations.
3-phasecommercial-standbyindustrial-standby
Generac
Generac SG060
60 kW natural gas/LP standby. No diesel logistics. Largest dealer network (10,000+) for fast local service.
60 kW standby · Natural Gas · Liquid-cooled
60 kW natural gas standby for mid-size commercial, medical clinics, and chain restaurants.
60 kW standby natural gas generator with Generac 4.5L turbocharged spark-ignited engine. EPA certified stationary emergency. Single and three-phase configurations.
3-phasecommercial-standbyindustrial-standby
Generac
Generac SG070
70 kW natural gas/LP industrial standby. No fuel storage required.
70 kW standby · Natural Gas · Liquid-cooled
70 kW natural gas standby for large restaurants, small hotels, and commercial buildings on gas mains.
70 kW standby natural gas generator with Generac 4.5L turbocharged spark-ignited engine. EPA certified stationary emergency and demand response. Single and three-phase.
80 kW natural gas standby for assisted living, mid-size offices, and retail distribution centers.
80 kW standby natural gas generator with Generac 9.0L V8 naturally aspirated spark-ignited engine. EPA certified stationary emergency and demand response. Single and three-phase.
3-phasecommercial-standbyindustrial-standby
Generac
Generac SG100
100 kW natural gas industrial standby. No on-site diesel storage.
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby for hotels, office campuses, and healthcare clinics with gas service.
100 kW industrial gaseous standby generator. Generac's commercial natural gas/LP platform competing with Kohler KG100 and Cummins C100 N6.
240 kW prime natural gas for continuous-duty applications — remote industrial, mining, and off-grid commercial operations.
240 kW prime-rated natural gas generator. PSI 14.6L V8 turbocharged, Stamford S4L1DD alternator, DSE 7420 MKII. Continuous duty, 3-phase only. Made in USA.
3-phaseprime-powerremote-site
Gillette
Gillette SP-1500
Factory-direct. PSI 8.8L turbo V8 + DSE controller — no proprietary lock-in. 3-7 day lead times.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas / 130 kW LP standby for large commercial, hotels, multi-family, and schools.
150 kW natural gas / 130 kW LPG stationary standby generator. Made-in-USA commercial gaseous unit with PSI 8.8L turbocharged V8 engine, Stamford alternator, and DSE 7420 MKII controller.
3-phasecommercialhealthcare
Gillette
Gillette SP-2000P
Factory-direct. PSI 8.8L high-output turbo V8 + DSE controller — no proprietary lock-in. 3-7 day lead times.
200 kW standby · Natural Gas · Liquid-cooled
200 kW natural gas standby for commercial buildings, hotels, multi-family housing, and data centers.
200 kW natural gas stationary standby generator. Made-in-USA commercial unit with PSI 8.8L high-output turbocharged V8, Stamford alternator, and DSE 7420 MKII controller. NG only.
3-phasecommercialhotel
Gillette
Gillette SP-2500P
Factory-direct. PSI 13L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
250 kW standby · Natural Gas / LPG · Liquid-cooled
250 kW natural gas / 165 kW LP standby for hotels, data centers, and large commercial facilities.
250 kW natural gas / 165 kW LPG stationary standby generator. PSI 13L inline-6 turbocharged engine, Stamford S4L1DD alternator, DSE 7420 MKII. Made in USA.
3-phasecommercialhotel
Gillette
Gillette SP-410
Factory-direct. PSI V6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
40 kW standby · Natural Gas / LPG · Liquid-cooled
40 kW natural gas/LP standby for small commercial buildings, restaurants, and retail stores.
40 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 4.3L V6 engine, Stamford alternator, and DSE 7420 MKII controller.
3-phasecommercialrestaurant
Gillette
Gillette SP-620
Factory-direct. PSI V8 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
60 kW standby · Natural Gas / LPG · Liquid-cooled
60 kW natural gas/LP standby for mid-size commercial — restaurants, retail, schools, and multi-family buildings.
60 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 5.7L V8 engine, Stamford alternator, and DSE 7420 MKII controller.
3-phasecommercialrestaurant
Gillette
Gillette SP-960
Factory-direct. PSI 5.7L TCAC engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
96 kW standby · Natural Gas / LPG · Liquid-cooled
96 kW natural gas / 80 kW LP standby for mid-size commercial, schools, worship centers, and light industrial.
96 kW natural gas / 80 kW LPG stationary standby generator. Made-in-USA commercial gaseous unit with PSI engine, Stamford alternator, and DSE 7420 MKII controller.
3-phasecommercialrestaurant
Gillette
Gillette SPD-1000
Factory-direct. Perkins engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial buildings, telecom sites, pump stations, and light industrial facilities.
100 kW stationary diesel standby generator with Perkins 1104D-E44TAG2 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPD-1500
Factory-direct. Perkins 7.01L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hospitals, hotels, commercial buildings, and municipal infrastructure.
150 kW stationary diesel standby generator with Perkins 1106D-E70TAG4 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPD-2000
Factory-direct. Perkins 7.01L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, hotels, water treatment, and mid-size commercial or municipal facilities.
200 kW stationary diesel standby generator with Perkins 1106D-E70TAG5 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPD-600
Factory-direct. Perkins engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for commercial buildings, telecom sites, retail stores, and pump stations.
60 kW stationary diesel standby generator with Perkins 1104D-E44TG1 engine. Made-in-USA with Stamford UCI224F alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPJD-1000
Factory-direct. John Deere 4045 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, telecom, pump stations, and municipal buyers.
100 kW stationary diesel standby generator with John Deere 4045HF285 engine. USA factory built with Stamford UCI274D alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPJD-1550
Factory-direct. John Deere 6068 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
155 kW standby · Diesel · Liquid-cooled
155 kW diesel standby for hospitals, hotels, commercial buildings, and municipal infrastructure.
155 kW stationary diesel standby generator with John Deere 6068HF285 engine. USA factory built with Stamford UCI274G alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPJD-2100
Factory-direct. John Deere 6068 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
210 kW standby · Diesel · Liquid-cooled
210 kW diesel standby for hospitals, hotels, water treatment, and commercial facilities.
210 kW stationary diesel standby generator with John Deere 6068HF485 engine. USA factory built with Stamford UCID274J alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPJD-600
Factory-direct. John Deere engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for cost-conscious commercial, telecom, and municipal buyers.
60 kW stationary diesel standby generator with John Deere engine. USA factory built unit with Deep Sea controller and Stamford alternator.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPVD-2500
Factory-direct. Volvo Penta 7.7L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, hotels, data centers, and mid-size commercial or industrial facilities.
200 kW Tier 4 Final diesel for hospitals, municipal sites, construction, and prime power.
200 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1180VE 10.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
250 kW Tier 4 Final diesel for hospitals, municipal sites, and prime power.
250 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1381VE 12.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Kohler
Kohler 100REOZJF
THD below 3% at 100 kW -- the healthcare and commercial default. John Deere 4045HF285 with Decision-Maker controller.
100 kW standby · Diesel · Liquid-cooled
100 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
100 kW diesel commercial standby generator. Mid-range diesel workhorse for commercial facilities, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 100REZGD
100 kW industrial gaseous -- General Motors Vortec 5.7L with PM alternator, sub-3% THD. No on-site fuel storage required.
100 kW standby · LPG · Liquid-cooled
100 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
100 kW LPG industrial standby generator. Enclosed gaseous standby for commercial and institutional applications requiring clean-burning propane fuel.
3-phasecommercialhealthcare
Kohler
Kohler 100RZGD
100 kW industrial gaseous -- General Motors Vortec 5.7L with PM alternator, sub-3% THD. No on-site fuel storage required.
100 kW standby · LPG · Liquid-cooled
100 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
100 kW LPG industrial standby generator. Open-frame gaseous standby for commercial and industrial applications on propane.
3-phasecommercialhealthcare
Kohler
Kohler 125REOZJ4
THD below 3% at 130 kW -- the healthcare and commercial default. John Deere 6068HG550 with Decision-Maker controller.
130 kW standby · Diesel · Liquid-cooled
130 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
130 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 125REOZJG
THD below 3% at 125 kW -- the healthcare and commercial default. John Deere 4045HF285K with Decision-Maker controller.
125 kW standby · Diesel · Liquid-cooled
125 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
125 kW diesel commercial standby generator. John Deere-powered mid-range diesel for commercial, healthcare, and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 145REOZT4
130 kW mobile diesel trailer -- Tier 4 John Deere 6068HG550. DOT-towable for large temporary power and emergency deployment.
130 kW standby · Diesel · Liquid-cooled
130 kW mobile standby for large construction projects, event power, emergency response, and planned outage bridge power.
130 kW diesel mobile trailer Tier 4 Final commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 150REOZJ4
150 kW standby · Diesel · Liquid-cooled
150 kW diesel commercial standby generator powered by John Deere.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 150REOZJF
THD below 3% at 154 kW -- the healthcare and commercial default. John Deere 6068HF285K with Decision-Maker controller.
154 kW standby · Diesel · Liquid-cooled
154 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
154 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 150REZGC
150 kW industrial gaseous -- PSI 8.8L Industrial with PM alternator, sub-3% THD. No on-site fuel storage required.
150 kW standby · LPG · Liquid-cooled
150 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
150 kW LPG industrial standby generator. Enclosed gaseous standby with PSI engine for mid-range commercial and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 150RZGC
150 kW industrial gaseous -- PSI 8.8L Industrial with PM alternator, sub-3% THD. No on-site fuel storage required.
150 kW standby · LPG · Liquid-cooled
150 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
135 kW LPG industrial standby generator. Open-frame gaseous standby with PSI engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 175REOZT4
150 kW standby · Diesel · Liquid-cooled
150 kW diesel mobile trailer Tier 4 Final commercial standby generator powered by John Deere.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 180REOZJG
THD below 3% at 180 kW -- the healthcare and commercial default. John Deere 6068HFG82E with Decision-Maker controller.
180 kW standby · Diesel · Liquid-cooled
180 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
180 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 180REZXB
190 kW industrial gaseous -- Doosan D111TIC with PM alternator, sub-3% THD. No on-site fuel storage required.
190 kW standby · LPG · Liquid-cooled
190 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
190 kW LPG industrial standby generator. Enclosed gaseous standby with Doosan engine for commercial, healthcare, and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 180RZXB
190 kW industrial gaseous -- Doosan D111TIC with PM alternator, sub-3% THD. No on-site fuel storage required.
190 kW standby · LPG · Liquid-cooled
190 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
170 kW LPG industrial standby generator. Open-frame gaseous standby with Doosan engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 200REOZJF
200 kW standby · Diesel · Liquid-cooled
200 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
200 kW diesel commercial standby generator. Large commercial diesel for hospitals, data centers, and institutional facilities.
Tier 33-phasehospitaldata-center
Kohler
Kohler 200REZXB
200 kW industrial gaseous -- Doosan D111TIC with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
200 kW standby · LPG · Liquid-cooled
200 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
200 kW LPG industrial standby generator. Enclosed gaseous standby with Doosan engine for commercial, healthcare, and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 200RZXB
200 kW industrial gaseous -- Doosan D111TIC with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
200 kW standby · LPG · Liquid-cooled
200 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
175 kW LPG industrial standby generator. Open-frame gaseous standby with Doosan engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 230REOZJE
230 kW diesel standby with sub-3% THD -- John Deere 6090HF484C. Healthcare and data center default in this power class.
230 kW standby · Diesel · Liquid-cooled
230 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
230 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 40REOZK
40 kW compact diesel standby -- Kohler KDI 3404TM turbo at 1800 RPM. Sub-3% THD with quiet enclosure options.
40 kW standby · Diesel · Liquid-cooled
40 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
40 kW diesel commercial standby generator. Kohler-powered diesel for commercial, healthcare, education, and government standby applications.
3-phasecommercialhealthcare
Kohler
Kohler 40REOZK4
40 kW compact diesel standby -- Kohler KDI 2504 TCR turbo at 1800 RPM. Sub-3% THD with quiet enclosure options.
40 kW standby · Diesel · Liquid-cooled
40 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
40 kW Tier 4 Final diesel commercial standby generator. Kohler-powered diesel with EPA Tier 4 Final emissions compliance for commercial and institutional applications.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 45REOZT4
40 kW mobile diesel trailer -- Tier 4 Kohler KDI 2504 TCR. Road-towable for temporary power, construction, and emergency deployment.
40 kW standby · Diesel · Liquid-cooled
40 kW mobile standby for construction sites, planned outages, and emergency response requiring Tier 4 emissions compliance.
45 kW Tier 4 Final diesel mobile trailer generator. Kohler-powered portable diesel for construction, events, and temporary power applications.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 48REOZK4
47 kW compact diesel standby -- Kohler KDI 3404 TCR turbo at 1800 RPM. Sub-3% THD with quiet enclosure options.
47 kW standby · Diesel · Liquid-cooled
47 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
48 kW Tier 4 Final diesel commercial standby generator. Kohler-powered diesel with EPA Tier 4 Final emissions compliance for commercial and institutional applications.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 50REOZK
50 kW compact diesel standby -- Kohler KDI 3404TM turbo at 1800 RPM. Sub-3% THD with quiet enclosure options.
50 kW standby · Diesel · Liquid-cooled
50 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
50 kW diesel commercial standby generator. Kohler-powered diesel for commercial, healthcare, education, and government standby applications.
60 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
60 kW diesel commercial standby generator. Kohler-powered diesel for commercial, healthcare, education, and government standby applications.
3-phasecommercialhealthcare
Kohler
Kohler 80REOZJ4
85 kW compact diesel standby -- John Deere 4045HFG04 turbo at 1800 RPM. Sub-3% THD with quiet enclosure options.
85 kW standby · Diesel · Liquid-cooled
85 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
80 kW Tier 4 Final diesel commercial standby generator. John Deere-powered diesel with EPA Tier 4 Final emissions compliance for commercial and institutional applications.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 80REOZJF
81 kW compact diesel standby -- John Deere 4045HF285H turbo at 1800 RPM. Sub-3% THD with quiet enclosure options.
81 kW standby · Diesel · Liquid-cooled
81 kW commercial standby for small-to-mid commercial, retail, branch offices, and light industrial applications on diesel.
81 kW diesel commercial standby generator. John Deere-powered diesel for commercial, healthcare, education, and government standby applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 90REOZT4
85 kW mobile diesel trailer -- Tier 4 John Deere 4045HFG04. DOT-towable for temporary and emergency power deployment.
85 kW standby · Diesel · Liquid-cooled
85 kW mobile standby for construction, planned utility outages, disaster response, and rental fleet applications.
90 kW Tier 4 Final diesel mobile trailer generator. John Deere-powered portable diesel for construction, events, and temporary power applications.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler KG100
100 kW industrial gaseous -- Kohler KG6208THD turbo V8, sub-3% THD, rare-earth PM alternator. No fuel storage or SPCC required.
100 kW commercial standby on NG/LP for mid-size commercial, multi-family, and light industrial with reliable gas supply.
100 kW gaseous-fueled commercial standby generator. Upper-mid-range industrial gaseous unit for larger commercial facilities on natural gas or propane.
3-phasemedium-commerciallarge-retail
Kohler
Kohler KG125
125 kW industrial gaseous -- Kohler KG6208THD turbo V8 with PM alternator. No fuel storage, lower emissions, sub-3% THD.
45 kW commercial standby on NG/LP for retail, offices, and light commercial where diesel storage is impractical or prohibited.
45 kW gaseous-fueled commercial standby generator with Brushless Rare-Earth Permanent-Magnet alternator. Industrial gaseous unit for commercial backup on natural gas or propane.
3-phasecommercialhealthcare
Kohler
Kohler KG50
53 kW gaseous standby -- Kohler KG6208 NA V8 at 1800 RPM with rare-earth PM alternator.
53 kW gaseous-fueled commercial standby generator with Brushless Rare-Earth Permanent-Magnet alternator. Industrial gaseous unit for commercial backup on natural gas or propane.
3-phasecommercialhealthcare
Kohler
Kohler KG60
60 kW gaseous standby -- no fuel storage, no SPCC plan. Kohler KG6208 NA V8 at 1800 RPM with rare-earth PM alternator.
80 kW commercial standby on NG/LP for mid-size commercial, multi-family, and light industrial with reliable gas supply.
80 kW gaseous-fueled commercial standby generator. Industrial gaseous unit for medium commercial backup on natural gas or propane.
3-phasemedium-commercialmulti-tenant-retail
MQ Power
MQ Power DCA-125 WhisperWatt
WhisperWatt 125 kVA - 66 dBA at 23 ft, Isuzu BR-4HK1X 5.2L, 169-gal tank. DEF/SCR Tier 4 Final.
110 kW standby · Diesel · Liquid-cooled
Portable power at 100 kW prime. Diesel at 7.1 gph with a 169-gal tank.
125 kVA (100 kW prime) portable diesel generator. WhisperWatt Super-Silent with an Isuzu BR-4HK1X engine, DEF/SCR and a 169-gallon tank.
Tier 4 Final3-phaseconstruction-largerental-fleet
MQ Power
MQ Power DCA-150 WhisperWatt
WhisperWatt 150 kVA - John Deere 6068HFG05 6.8L, 66 dBA at 23 ft, 319-gal tank.
132 kW standby · Diesel · Liquid-cooled
Portable power at 120 kW prime for large construction, events and commercial backup.
150 kVA (120 kW prime) portable diesel generator. John Deere-powered WhisperWatt Super-Silent for major construction, large events, and emergency commercial power.
WhisperWatt 45 kVA - 66 dBA at 23 ft, Isuzu 4LE2X 2.179L, single- and three-phase output, 79.2-gal tank.
40 kW standby · Diesel · Liquid-cooled
Mid-size portable at 36 kW prime. Diesel at 2.93 gph, for construction and events up to 36 kW.
45 kVA (36 kW prime) portable diesel generator. Compact WhisperWatt Super-Silent for construction sites, events, and commercial temporary power.
Tier 4 Final3-phaseconstruction-largerental-fleet
MQ Power
MQ Power
MQ Power DCA-600 WhisperWatt
480 kW prime from a Volvo TWD1672GE 16.1L, 71 dBA at 23 ft, 825 hp gross.
528 kW standby · Diesel · Liquid-cooled
Portable power at 480 kW prime for construction and emergency response.
600 kVA (480 kW prime) portable diesel generator. Volvo-powered WhisperWatt at 71 dBA.
Tier 4 Final3-phaseconstruction-largerental-fleet
MQ Power
MQ Power DCA-70 WhisperWatt
WhisperWatt 70 kVA - 65 dBA at 23 ft. Isuzu BR-4JJ1X 3.0L, DEF/SCR Tier 4 Final, 103-gal tank, single- and three-phase output.
62 kW standby · Diesel · Liquid-cooled
Commercial temporary power at 56 kW prime. Diesel at 4.4 gph and a 103-gal tank.
70 kVA (56 kW prime) portable diesel generator. Quiet WhisperWatt Super-Silent for large construction sites, commercial events, and emergency temporary power.
Tier 4 Final3-phaseconstruction-largerental-fleet
MTU
MTU 10V0068 GS100
100 kW NG/LP standby on MTU's own 6.8L V10. Dual-fuel capable, compact under 87 in, 3-way catalyst, no diesel storage needed.
100 kW standby · Natural Gas / LPG · Liquid-cooled
Commercial dual-fuel standby at 100 kW. 1,100 CFH natural gas, same 100 kW on LP, compact V10 footprint.
100 kW natural gas standby generator with MTU 6.8LT V10 engine, 6.8 L turbocharged 10-cylinder V, dual-fuel capable (NG/LP), 1800 rpm. 3-way catalyst, EPA compliant.