The Thomson TS880 is Thomson Power Systems' mission-critical automatic transfer switch, covering 800A to 4000A with insulated-case power switching devices. Available in both 3-cycle and 30-cycle withstand configurations, it serves data centers, hospitals, and facilities where power continuity and selective coordination are non-negotiable.
The TS880 uses the TSC 900 controller as standard — a 7-inch color touchscreen with front-panel programming, comprehensive event logging, and Modbus communication. All configurations (open, closed, soft-load, bypass-isolation, service entrance, dual source) are available across the full 800-4000A range. The 30-cycle design shares its platform with Thomson's UL 1558 low-voltage power circuit breaker switchgear.
The TS880 bypass-isolation uses draw-out transfer power switching devices with key interlock mechanisms, mounted in separate barriered compartments from the ATS. The procedure:
Transfer load to the preferred source via the bypass handle
Isolate the ATS from both sources using the key interlock mechanism
Draw out the transfer switching devices for inspection or replacement
Service contacts, mechanisms, and controller with the load running on the bypassed source
Return draw-out switches, release interlocks, and return to automatic operation
The break-before-make bypass design prevents utility and generator paralleling under any circumstance. For units with closed-transition capability, the bypass can be operated in make-before-break sequence at the operator's direction.
The TS880 CTTS uses electrically interlocked insulated-case power switching units with the TSC 900 controller's built-in sync check relay. The controller monitors voltage differential and slip frequency between sources. When both are within threshold, it initiates a closed transition lasting less than 100ms. If the paralleling timer exceeds its limit, extended paralleling protection opens the other source within 500ms.
Soft-load transition is available as an additional ordering option for process loads requiring gradual transfer ramping.
We service Thomson TS880 units in Bay Area data centers and healthcare facilities. The insulated-case switching mechanism is extremely robust at these current levels — contact life far exceeds contactor-based alternatives in this amperage class.
The 4000A bypass-isolation units are physically massive — at 92" x 96" x 90" and up to 7,500 lbs (4-pole), they require rigging equipment and careful access planning. We've seen installation delays on retrofit projects where the freight elevator couldn't accommodate the weight or dimensions. Specify access requirements during design to avoid costly field surprises.
The TSC 900 touchscreen controller is a significant upgrade from the TSC 7320 used on the TS870. The 7-inch color display makes programming and troubleshooting faster during service calls, and the event logging with time/date stamps provides valuable forensic data when investigating transfer events.
Frequently Asked Questions
What amperage range does the Thomson TS880 cover?
The TS880 covers 800A through 4000A in 3-pole and 4-pole configurations. Standard frame sizes are 800A, 1000A, 1200A, 1600A, 2000A, 2500A, 3000A, 3200A, and 4000A. The voltage range is 208-600V for three-phase, 3 or 4-wire systems at 50/60 Hz.
What are the 3-cycle withstand ratings?
All frames 800-4000A share the same 3-cycle withstand: 100,000A at 240V, 100,000A at 480V, and 85,000A at 600V. With optional overcurrent trip units, interrupting ratings match these withstand values.
What are the 30-cycle withstand ratings?
The 30-cycle models provide 85,000A 3-cycle at all voltages up to 600V, plus 65,000A 30-cycle at all voltages up to 600V. For power switching devices without trip units, withstand is 65,000A at both 3-cycle and 30-cycle.
What controller does the TS880 use?
The TS880 uses the TSC 900 controller as standard, featuring a 7-inch color touchscreen with front-panel programming, 8 programmable output contacts, RS232 Modbus via the GHC (Graphical Human Controller), optional Ethernet Modbus TCP, USB ports, and comprehensive event logging. The TSC 900 includes built-in sync check relay for closed-transition applications.
Does the TS880 offer bypass-isolation?
Yes. The bypass-isolation configuration uses draw-out transfer power switching devices with key interlock mechanisms, mounted in separate barriered compartments. All external power cabling connects in the bypass compartment. The break-before-make design prevents utility and generator paralleling under any circumstance. Bypass units with closed-transition may be operated in make-before-break sequence at the operator's direction.
What are the physical dimensions?
ATS-only (NEMA 1): 800-2000A share one cabinet at 91.5 x 36 x 42 inches (1,500 lbs); 2500A is 91.5 x 36 x 60 inches (1,800 lbs); 3000/3200A is 91.5 x 36 x 60 inches (2,000 lbs); 4000A is 91.5 x 48 x 72 inches (3,000 lbs). Bypass-isolation units are significantly larger — the 4000A bypass unit measures 92 x 96 x 90 inches and weighs 6,500-7,500 lbs depending on pole count.
What configurations are available beyond standard ATS?
Service entrance (SE) with integrated overcurrent protection. Bypass-isolation with draw-out switches. Closed transition (momentary, <100ms). Soft-load transition. Dual utility control (DU). Dual standby generator (DSG slave ATS). Dual prime generator (DPG). CSA Type B with integrated overcurrent and ground fault protection. 30-cycle versions of all configurations.
How does the TS880 compare to the ASCO 7000 Series?
Both target mission-critical applications. The TS880 starts at 800A with insulated-case switching and offers both 3-cycle and 30-cycle models. The ASCO 7000 starts at 30A with contactor switching. The TS880's 30-cycle design shares its platform with Thomson's UL 1558 switchgear, enabling seamless integration into paralleling switchgear packages. ASCO has broader distributor availability; Thomson typically offers more competitive pricing on large-frame mission-critical units.
What seismic certifications does the TS880 have?
The TS880 is seismic certified per IBC 2012 Section 13, Occupancy Category IV, ASCE7-05 Region 3 (minimum Ss=200%), and OSHPD certified. The OSHPD certification qualifies it for California hospital installations where healthcare-specific seismic requirements apply.
Key Terms
Insulated-case switch
Power switching device with molded insulation surrounding the contacts and mechanism. Used in the TS880 for high withstand ratings. The 30-cycle design shares the same platform as Thomson's UL 1558 low-voltage power circuit breaker switchgear.
Bypass-isolation
Configuration with draw-out transfer switches and key interlocks in separate barriered compartments. Allows maintenance personnel to isolate and bypass the ATS without interrupting power. Break-before-make design prevents source paralleling.
3-cycle vs 30-cycle withstand
3-cycle (50ms at 60Hz) is standard. 30-cycle (500ms) provides additional margin for selective coordination in mission-critical facilities. The 30-cycle design uses insulated-case power switching devices rated 800-4000A.
TSC 900 controller
Thomson's standard controller for the TS880 with 7-inch color touchscreen, front-panel programming with password security, 8 programmable output contacts, RS232 Modbus via GHC, optional Ethernet Modbus TCP, USB ports, and event logging with time/date stamping.
Soft-load transition
A controlled ramp transfer that gradually shifts load between sources, minimizing transient voltage and frequency disturbances. Available as an ordering option on the TS880.
CSA Type B
TS880 option integrating overcurrent protection and ground fault protection within the ATS, eliminating the need for separate upstream protective devices.
Found in these gensets
Generator models that ship with or are commonly paired with the Thomson TS880 Automatic Transfer Switch.
Blue Star Power Systems
Blue Star MD1000-01
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component independence matter.
1000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12H-Y2PTAW-1 37.1L V12 engine, S6L1D alternator, DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD1250-01
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for industrial, data center, and utility-scale applications where value engineering and open-architecture components matter.
1250 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12R-Y2PTAW-1 49.0L V12 engine, S6L1D alternator, DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD1600-01
1.6 MW standby · Diesel · Liquid-cooled
1600 kW diesel standby for industrial, data center, and utility-scale applications where value engineering and non-proprietary components matter.
1600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW-1 65.4L V16 engine, S7L1D alternator, DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD2000-01
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for data centers, hospitals, and utility-scale applications where component independence and value engineering matter.
2000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW2-1 65.4L V16 engine, S7L1D alternator, DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD800-01
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for industrial plants, campus power, and data centers where value engineering and non-proprietary component access matter.
800 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12A2-Y2PTAW-2 33.9L V12 engine, S6L1D alternator, DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star NG1050-01
1.1 MW standby · Natural Gas / LPG · Liquid-cooled
1050 kW natural gas standby for data centers, campus power, and utility-scale gas applications where component independence matters.
1050 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 53L V16 turbocharged-aftercooled, DCP7310 controller, three-phase 480-4160V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG1050-01P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
900 kW prime natural gas for continuous-duty data center, CHP, and utility-scale applications needing 24/7 gas-fueled power.
900 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 53L V16 turbocharged-aftercooled, DCP7310 controller, three-phase 480-4160V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG1250-01
1.3 MW standby · Natural Gas · Liquid-cooled
1250 kW natural-gas-only standby for data centers and utility-scale facilities where gas-fueled backup and component independence matter.
1250 kW natural-gas-only standby generator from Blue Star Power Systems. PSI 53LHO high-output V16 turbocharged-aftercooled, DCP7310 controller, three-phase 480-4160V. LP not available.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG500-01
500 kW standby · Natural Gas / LPG · Liquid-cooled
500 kW natural gas standby for large commercial, campus, and data center facilities where gas-fueled backup and component independence matter.
500 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG500-01P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
450 kW prime natural gas for continuous-duty data center, CHP, and campus applications needing 24/7 gas-fueled power.
450 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG500-02
500 kW standby · Natural Gas · Liquid-cooled
500 kW natural-gas-only standby for data center, campus, and industrial facilities where gas-fueled backup and component independence matter.
500 kW natural-gas-only standby generator from Blue Star Power Systems. PSI 21.9LHO V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V. LP not available.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG600-01
600 kW standby · Natural Gas / LPG · Liquid-cooled
600 kW natural gas standby for data center, campus, and industrial facilities where gas-fueled backup and component independence matter.
600 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG600-01P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
540 kW prime natural gas for continuous-duty data center, CHP, and campus applications needing 24/7 gas-fueled power.
540 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG650-01
650 kW standby · Natural Gas / LPG · Liquid-cooled
650 kW natural gas standby for data center, campus, and industrial facilities where gas-fueled backup and component independence matter.
650 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG650-01P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
550 kW prime natural gas for continuous-duty data center, CHP, and campus applications needing 24/7 gas-fueled power.
550 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 32L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-600V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG800-01
800 kW standby · Natural Gas / LPG · Liquid-cooled
800 kW natural gas standby for data center, campus, and industrial facilities where gas-fueled backup and component independence matter.
800 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 40L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-4160V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star NG800-01P
Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled
660 kW prime natural gas for continuous-duty data center, CHP, and campus applications needing 24/7 gas-fueled power at scale.
660 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 40L V12 turbocharged-aftercooled, DCP7310 controller, three-phase 208-4160V.
3-phaselarge-commercialdata-center
Blue Star Power Systems
Blue Star PD500-01
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for industrial, data center, and campus facilities where value engineering and non-proprietary component access matter.
500 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2506C-E15TAG3 six-cylinder engine with charge air cooling, HCI534D alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD550-01
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for industrial, data center, and campus facilities where value engineering and open-architecture components matter.
550 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2506C-E15TAG4 six-cylinder engine with charge air cooling, HCI534E alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD600-01
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TAG3 six-cylinder engine with charge air cooling, HCI534E alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD750-01
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for industrial, data center, and mission-critical facilities where value engineering and non-proprietary components matter.
750 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TTAG7 turbocharged six-cylinder engine, S6L1D-C alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star VD500-01
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for industrial, data center, and campus facilities where value engineering and non-proprietary component access matter.
500 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1641GE-B 16.1L inline-six with DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD550-01
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for industrial, data center, and campus facilities where value engineering and open-architecture components matter.
550 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1642GE-B 16.1L inline-six with DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD550-04FT4
550 kW standby · Diesel · Liquid-cooled
550 kW Tier 4 Final diesel standby for industrial, data center, and campus facilities requiring current emissions and component independence.
550 kW standby / 500 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1682GE 16.12L inline-six, DCP7310 controller, three-phase 208-600V.
550 kW Tier 4 Final mobile diesel for industrial temporary power, planned outage support, and large-scale construction with clean emissions.
550 kW standby / 500 kW prime Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TWD1682GE six-cylinder engine, 572RSL6429 alternator, DCP7310 controller, 550-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD600-01
Standby: see spec sheet · Diesel · Liquid-cooled
Blue Star Power Systems VD600-01 diesel generator set.
3-phaselarge-commercialhospital
Blue Star Power Systems
Blue Star VD600-03
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1644GE 16.1L inline-six, DCP7310 controller, 208-600V.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD600-04FT4
600 kW standby · Diesel · Liquid-cooled
600 kW Tier 4 Final diesel standby for industrial, data center, and campus facilities requiring current emissions and component independence.
600 kW standby / 570 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1683GE 16.12L inline-six with SCR/DPF/DOC, DCP7310 controller, three-phase 208-600V.
600 kW Tier 4 Final mobile diesel for industrial temporary power, planned outage support, and large-scale construction.
600 kW standby / 570 kW prime Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TWD1683GE six-cylinder engine, 572RSL6431 alternator, DCP7310 controller, 550-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD700-01
700 kW standby · Diesel · Liquid-cooled
700 kW diesel standby for industrial, data center, and mission-critical facilities where value engineering and non-proprietary components matter.
700 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1744GE 17.3L inline-six, DCP7310 controller, 208-600V.
Tier 23-phaselarge-commercialhospital
Caterpillar
Cat 3412C
800 kW Cat diesel with 3412C V-12. Updated 3400-series with EMCP 4 controls. Proven reliability.
800 kW standby · Diesel · Liquid-cooled
800 kW standby for data centers, hospitals, and campuses with existing 3400-series fleet.
800 kW standby diesel generator with Cat 3412C V12 engine, 27.0L displacement. The current-generation 3412 with upgraded controls and improved fuel efficiency.
Tier 23-phasedata-centerhospital
Caterpillar
Cat 3508
850 kW Cat diesel with 3508 V-8. 34.5L between the 3412 and 3512. Proven 3500-series reliability.
850 kW standby · Diesel · Liquid-cooled
850 kW standby for industrial facilities, campuses, and mining operations with 3500-series standardization.
850 kW standby diesel generator with Cat 3508 V8 engine, 34.5L displacement. Purpose-built for industrial facilities, mining operations, and mission-critical power.
Tier 23-phaseindustrialcampus
Caterpillar
Cat 3508B
1 MW Cat diesel with 3508B V-8. Upgraded 3500-series for data centers. Megawatt from 8 cylinders.
1 MW standby · Diesel · Liquid-cooled
1 MW standby for data centers, hospitals, and mission-critical facilities preferring 3500-series platform.
1000 kW standby diesel generator with Cat 3508B V8 engine, 34.5L displacement. Built for data centers, hospitals, and paralleling arrays requiring 1 MW per unit.
Tier 23-phasedata-centerhospital
Caterpillar
Cat 3512
Diesel generator set with the Cat 3512 V-12 engine, rated 1000 to 1400 kVA at 50 Hz.
1 MW standby · Diesel · Liquid-cooled
Diesel power for data centers, large hospitals, and industrial campuses with CAT fleet.
1000-1400 kVA (50 Hz) diesel generator with Cat 3512 V-12 engine. 51.8L displacement, Woodward governor, continuous/prime/standby duty cycles.
3-phasecommercial-standbyindustrial
Caterpillar
Cat 3512B
Diesel generator set with the Cat 3512B V-12 engine, rated up to 1500 ekW mission critical standby at 60 Hz.
1.5 MW standby · Diesel · Liquid-cooled
1500 ekW mission critical standby for data centers, large hospitals, and critical infrastructure.
1230-1500 kW diesel generator with Cat 3512B V-12 engine. EUI fuel system, EMCP 4.2B controller, mission-critical and standby ratings.
3-phasecommercial-standbymission-critical
Caterpillar
Cat 3516
Diesel with CAT 3516 V-16 engine and EMCP 4.2 controller.
Standby: see spec sheet · Diesel · Liquid-cooled
Diesel standby for large data centers, hospitals, and industrial campuses with CAT fleet standardization.
Diesel generator with Cat 3516 turbocharged V-16 engine. Mission-critical platform for data centers, hospitals, and large industrial standby and prime power.
3-phasedata-centerhospital
Caterpillar
Cat 3516B
2000 kW standby diesel with CAT 3516B V-16 engine and EMCP 4.2B controller.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for data centers, large hospitals, and campus-scale critical infrastructure.
2500 kW diesel with CAT 3516C V-16. EPA Tier 4 Final. Best resale in class. Paralleling for multi-MW arrays.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby for hyperscale data centers, campus microgrids, and emission-regulated industrial.
2500 kW diesel standby generator with Cat 3516C V-16 engine. The largest Cat genset platform for mission-critical data centers and industrial power.
Tier 23-phasedata-centerhospital-large
Caterpillar
Cat 3516E
Diesel with CAT 3516E V-16 engine and EMCP 4.2B controller.
Standby: see spec sheet · Diesel · Liquid-cooled
Diesel standby for data centers, campus microgrids, and utility peak shaving.
Diesel generator with Cat 3516E V-16 engine. 78.1L displacement, Tier 2 equivalent, ATAAC aspiration for standby power.
Tier 23-phasecommercial-standbymission-critical
Caterpillar
Cat C15
500 kW diesel with CAT C15 ACERT inline-6. Best resale value in class. ~200 US dealers with deep parts inventory.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for hospitals, data centers, and large commercial with CAT fleet standardization.
500 kW diesel standby generator with Cat C15 ACERT engine. Large commercial standby for hospitals, high-rises, and municipal infrastructure.
Tier 23-phasehospitalhigh-rise
Caterpillar
Cat C175-16
Up to 3100 kW diesel with CAT C175-16 V-16. Voltages from 220 to 13,800 volts.
3 MW standby · Diesel · Liquid-cooled
Diesel generator rated up to 3100 kW for data centers, campus microgrids, and mission-critical infrastructure.
2500-3100 kW diesel generator with Cat C175-16 SCAC V-16 engine. 84.7L displacement, Tier 2, mission-critical and standby power for data centers and large industrial facilities.
Tier 23-phasecommercial-standbymission-critical
Caterpillar
Cat C175-20
Diesel with CAT C175-20 V-20 engine and EMCP 4.2 controller. Medium-voltage capable.
Standby: see spec sheet · Diesel · Liquid-cooled
Diesel standby for data centers, utility-scale backup, and campus microgrids.
Diesel generator with Cat C175-20 SCAC V-20 engine. 105.8L displacement, standby, mission-critical, prime, and continuous duty cycles for large industrial and utility applications.
3-phasecommercial-standbymission-critical
Caterpillar
Cat C27
800 kW diesel with CAT C27 V-12.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel generator for mission-critical data centers, large hospitals, and industrial campuses.
680-800 kW diesel generator set with Cat C27 ACERT V-12 engine. Tier 2, MEUI fuel system, EMCP 4 controller.
Tier 23-phasecommercial-standbyindustrial
Caterpillar
Cat C32
1000 kW diesel with CAT C32 V-12. Best resale value in class. ~200 US dealers. Paralleling for multi-MW.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for Tier III data centers, large hospitals, and industrial campuses with CAT fleet.
1000 kW diesel standby generator with Cat C32 ACERT V-12 engine. Mission-critical platform for data centers, hospitals, and large campus power.
Tier 23-phasedata-centerhospital
Caterpillar
Cat C32B
1500 kW diesel with CAT C32B. EPA Tier 2.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier III+ data centers, hospitals, and mission-critical campus infrastructure.
1500 kW diesel standby generator with Cat C32B engine. Tier 2, EUI fuel system, Cat ECS/GCCP controller. The D1500 platform.
Tier 23-phasedata-centermission-critical
Caterpillar
Cat D1500
1.5 MW Cat diesel with C32B V-12. Cat's newest flagship. Maximum power density for data centers.
1.5 MW standby · Diesel · Liquid-cooled
1.5 MW standby for Tier III+ data centers and large hospitals needing maximum single-unit density.
1500 kW standby diesel generator with Cat C32B V12 engine, 32.1L displacement. Cat's newest 1.5 MW platform — maximum power density for space-constrained data centers.
Tier 23-phasedata-centerhospital
Caterpillar
Cat G3512
750 kW natural gas with CAT G3512 V-12. Continuous/prime rated. Biogas capable. Best resale in gas class.
750 kW standby · Natural Gas · Liquid-cooled
750 kW natural gas continuous/CHP for industrial cogeneration, distributed generation, and campus power.
750 kW natural gas generator with Cat G3512 turbocharged V-12 engine. Continuous and prime-rated platform for cogeneration, biogas, and distributed power.
3-phasecontinuous-powerprime-power
Caterpillar
Cat G3516H
1982 kW natural gas with CAT G3516H. 43.5% electrical efficiency. Cogeneration-ready.
2.0 MW standby · Natural Gas · Liquid-cooled
1982 kW natural gas continuous/CHP for industrial cogeneration, distributed generation, and utility power.
1982 kW continuous natural gas generator with Cat G3516H engine. High-efficiency combined heat and power for industrial, utility, and distributed generation.
3-phasecogenerationdistributed-generation
Caterpillar
Cat G3516H
Natural gas with CAT G3516H. Medium-voltage capable. Cogeneration-ready.
2.0 MW standby · Natural Gas · Liquid-cooled
Natural gas continuous/cogeneration for industrial CHP, distributed generation, and campus power.
Continuous-duty natural gas generator with Cat G3516H engine. Low-emission gas power for cogeneration, distributed generation, and industrial applications.
3-phasecontinuous-dutycogeneration
Caterpillar
Cat G3520E
2022 kW natural gas with CAT G3520E. 41.5% electrical efficiency. Cogeneration-ready.
2.0 MW standby · Natural Gas · Liquid-cooled
2022 kW natural gas continuous/CHP for industrial cogeneration, distributed generation, and baseload power.
2022 kW continuous natural gas generator with Cat G3520E engine. High-efficiency CHP platform for industrial, utility, and distributed generation.
3-phasecogenerationdistributed-generation
Caterpillar
Cat G3520H
2500 kW natural gas with CAT G3520H. Medium-voltage capable. Hydrogen capability on certain configurations.
2.5 MW standby · Natural Gas · Liquid-cooled
2500 kW natural gas continuous/cogeneration for industrial CHP, distributed generation, and campus power.
Up to 2500 ekW continuous natural gas generator at 50 Hz with Cat G3520H engine. 97.5L displacement, up to 25% hydrogen by volume capability on certain configurations, for cogeneration and distributed generation.
3-phasecontinuous-dutycogeneration
Caterpillar
Caterpillar 3412
Diesel generator set built on the Cat 3412C V12 engine, rated 680 to 900 kVA at 50 Hz.
720 kW standby · Diesel · Liquid-cooled
Diesel power for large industrial, hospitals, and mission-critical facilities with CAT fleet standardization.
The Caterpillar 3412C is a 680-900 kVA diesel generator built on the 27.02L V12 engine. ADEM A5 governor. Fuel: 45.3 gal/hr at 100% load (648 ekW prime, 50 Hz). Legacy platform for hospitals, campuses, and industrial sites.
3-phasehospital-largeindustrial
Caterpillar
Caterpillar 3512C
Diesel standby generator set with the Cat 3512C V-12 engine, rated 1500 ekW standby at 60 Hz. EPA Tier 2 for stationary emergency use.
1.5 MW standby · Diesel · Liquid-cooled
1500 ekW diesel standby for data centers, hospitals, and industrial sites.
The Caterpillar 3512C is a 1500 kW standby diesel generator. 51.8L V12 ATAAC, 14.7:1 compression, EPA Tier 2. Fuel: 104.6 gal/hr at full load. Medium-voltage outputs to 13,800V for mission-critical applications.
Tier 23-phasedata-centerhospital-large
Caterpillar
Caterpillar C18
600 kW diesel with CAT C18 ACERT inline-6. Best resale. ~200 US dealers.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for large data centers, hospitals, and industrial plants with CAT fleet.
The Caterpillar C18 ACERT is a 600 kW standby diesel generator with EPA Tier 2 certification. 18.1L inline-6 with MEUI injection. Fuel: 42.7 gal/hr at full load. Supports 4160V medium-voltage for hospital and campus applications.
Tier 23-phasehospital-mediumcampus
Caterpillar
Caterpillar G3412
512 kW natural gas with CAT G3412 V-12. No diesel infrastructure needed. EMCP 4 controller. ~200 US dealers.
512 kW standby · Natural Gas · Liquid-cooled
512 kW natural gas standby for large hospitals, campuses, and data centers on gas mains.
The Caterpillar G3412 is a 512 kW standby natural gas generator built on the 27L V12 G3412C engine. EPA Subpart JJJJ certified. EMCP 4 controller. Dry weight 14,330 lb. Complete specs from OEM sheet.
1 MW standby diesel with the Cummins QST30 30.5-liter V-12 engine, EPA Tier 2.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure requiring megawatt-class power.
1000 kW diesel standby generator with QST30 30.5L V-12 engine, liquid-cooled, for data center, hospital, and mission-critical standby applications requiring megawatt-class power.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1000 N6
1000 kW standby natural gas generator set with the Cummins QSK60G engine.
1 MW standby · Natural Gas · Liquid-cooled
1000 kW natural gas standby for data centers, large campuses, and utility peak shaving on gas.
1000 kW standby natural gas generator with QSK60G V16 engine. EPA NSPS certified, 36.4% electrical efficiency at 100% rated load (ISO 3046/1), pipeline natural gas.
3-phasecommercial-standbyindustrial
Cummins
Cummins C1100 D6
1100 kW diesel with QSK38 V-12 engine. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.
1.1 MW standby · Diesel · Liquid-cooled
1100 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure requiring above-megawatt power.
1100 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1250 D6
1250 kW / 1563 kVA standby diesel with the Cummins QSK38-G17 engine, EPA Tier 2, with PC 3.3 as the standard controller.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure.
1250 kW diesel standby generator with the Cummins QSK38-G17 engine, EPA Tier 2, with PC 3.3 as the standard controller, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1500 D6
1500 kW standby / 1365 kW prime at 60 Hz from the Cummins QSK50 V-16 engine with MCRS fuel injection.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants.
1500 kW diesel standby generator with QSK50 50.3L V-16 engine and MCRS fuel injection. EPA Tier 2 compliant engine with 2P2L cooling, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C500 N6
500 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel infrastructure needed.
500 kW standby · Natural Gas · Liquid-cooled
500 kW natural gas standby for data centers, large hospitals, and campus microgrids on gas mains.
500 kW natural gas standby generator with GTA 28E V12 engine. 500 kW / 625 kVA standby, PowerCommand 3.3 controls, 6994 CFH full-load, open set dimensions 166 x 82 x 98 in. UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C750 D6
750 kW standby diesel generator set with a Cummins QSK23-G3 engine and the HPI-PT full authority electronic fuel system.
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
750 kW standby diesel generator set at 60 Hz with a Cummins QSK23-G3 23.1L inline-6 engine and HPI-PT fuel injection, for data center, hospital, and mission-critical standby applications.
3-phasecommercial-standbylarge-commercial
Cummins
Cummins C750 N6
750 kW standby natural gas generator set on the Cummins GTA50 engine, with PowerCommand 3.3 paralleling control functions.
750 kW standby · Natural Gas · Liquid-cooled
750 kW natural gas standby for mission-critical data centers and large campus power on gas mains.
750 kW standby natural gas generator with GTA50 engine. PowerCommand 3.3 controls, AmpSentry protection, NFPA 110 Type 10 load acceptance; UL 2200 certification on select models.
3-phasecommercial-standbyindustrial
Cummins
Cummins C800 D6
800 kW standby diesel generator set with a Cummins QSK23-G3 engine and the HPI-PT full authority electronic fuel system.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses requiring N+1 redundancy.
800 kW standby, 727 kW prime diesel generator set at 60 Hz with a Cummins QSK23-G3 23.1L inline-6 engine and HPI-PT fuel injection, liquid-cooled, for data center, hospital, and mission-critical standby applications.
3-phasecommercial-standbylarge-commercial
Cummins
Cummins C900 D6
900 kW standby diesel at 60 Hz on the Cummins QST30-G3, a 30.5-liter V12 Quantum series engine.
900 kW standby · Diesel · Liquid-cooled
900 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure.
900 kW diesel standby generator at 60 Hz with Cummins QST30-G3 30.5L V-12 engine, liquid-cooled, for data center, hospital, and mission-critical standby applications.
3-phasecommercial-standbylarge-commercial
Cummins
Cummins KTA38
887 kW standby diesel generator at 50 Hz on the Cummins KTA38-G5 37.8-liter V12 engine.
887 kW standby · Diesel · Liquid-cooled
887 kW diesel standby for large industrial plants, hospitals, and mission-critical infrastructure.
887 kW standby / 811 kW prime diesel generator at 50 Hz. Cummins KTA38-G5 37.8L V12 with Cummins PT direct injection, for industrial, hospital, campus, and mining standby applications.
3-phaseindustrialhospital-large
Cummins
Cummins KTA50
1340 kW diesel with legendary KTA50 engine. Full Cummins vertical integration.
1.3 MW standby · Diesel · Liquid-cooled
1340 kW diesel standby for Tier III+ data centers, large hospitals, and heavy industrial plants.
1340 kW standby / 1200 kW prime diesel generator at 50 Hz. KTA50-GS8 50.3L V16 PT fuel injection, 2-pump 2-loop cooling. Legacy Cummins platform for data center, industrial, hospital, and mining standby applications.
3-phasedata-centerhospital-large
Cummins
Cummins QSK19
550 kW standby diesel with the Cummins QSK19-G4 engine, Modular Common Rail fuel injection and EPA Tier 2.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for large data centers, hospitals, and heavy industrial plants.
1160 kW standby diesel generator at 60 Hz on the Cummins QSK38-G5 37.7-liter V12 engine with Modular Common Rail fuel system.
1.2 MW standby · Diesel · Liquid-cooled
1160 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
1160 kW standby / 965 kW prime diesel generator at 60 Hz with the Cummins QSK38-G5 37.7L V12 MCRS engine. EPA Tier 2, 2P2L cooling, 24V starting.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK50
1500 kW standby diesel generator set with the Cummins QSK50-G4 engine, MCRS fuel system and 2P2L cooling.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for data centers, university campuses, and major industrial plants.
1500 kW standby / 1365 kW prime diesel generator with QSK50-G4 50.3L V16 MCRS engine. EPA Tier 2 and TA Luft compliant, 2P2L cooling, 24V starting.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK60
2000 kW diesel with QSK60 engine. Full Cummins vertical integration. Paralleling for multi-MW.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for hyperscale data centers, large hospitals, and campus microgrids.
2000 kW diesel standby generator. The data center industry standard — V-16, 60.2L, Tier 2. Cummins' flagship for mission-critical power.
Tier 23-phasedata-centerhospital
Cummins
Cummins QSK78
2750 kW diesel with QSK78 engine. Full Cummins vertical integration. Paralleling for multi-MW.
2.8 MW standby · Diesel · Liquid-cooled
2750 kW diesel standby for hyperscale data centers, critical infrastructure, and utility peaking.
2750 kW standby / 2500 kW prime diesel generator with QSK78-G14 V18 engine. EPA Tier 4 Final, 78-liter displacement for mission-critical and data center power.
Tier 4 Final3-phasedata-centerhospital
Cummins
Cummins QSK95
3010 kW standby diesel at 50 Hz with the Cummins QSK95-G10: 95.3 L V16, quad-turbocharged, capable of accepting 100% of rated load in one step.
3.0 MW standby · Diesel · Liquid-cooled
3010 kW diesel standby for hyperscale data centers, campus microgrids, and utility peak shaving.
3010 kW standby / 2690 kW prime diesel generator with QSK95-G10 V16 engine. EPA Tier 2, quad turbo, MCRS fuel injection, ISO 8528-G3 transient capability.
Tier 23-phasedata-centerhospital
Cummins
Cummins QSX15
500 kW standby, 450 kW prime and 303 kW continuous at 60 Hz from the 15-litre, six-cylinder Cummins QSX15-G9 engine.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for major hospitals, Tier III data centers, and large industrial facilities.
500 kW standby / 450 kW prime diesel generator with QSX15-G9 engine. 24-valve DOHC, 15-liter inline-6, EPA NSPS certified for commercial and industrial power.
3-phasecommercial-standbyindustrial
Generac
Generac SD1250
1250 kW industrial diesel with Mitsubishi engine. Competitive pricing vs CAT/Cummins. Paralleling for multi-MW systems.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
1.1 MW standby · Natural Gas / LPG · Liquid-cooled
1,050 kW (1 MW) natural gas standby for data centers, hospitals, industrial campuses, and utility-scale backup.
1,050 kW natural gas stationary standby generator. PSI 52.3L V16 turbocharged engine, Stamford AVK alternator, DSE 7420 MKII. Made in USA.
3-phasedata-centerhospital
Gillette
Gillette SP-5000
Factory-direct. PSI 21.9L V12 high-output + Deep Sea controller — no proprietary lock-in. 3-7 day lead times.
500 kW standby · Natural Gas / LPG · Liquid-cooled
500 kW natural gas / 300 kW LP standby for data centers, hospitals, and large industrial or campus microgrids.
500 kW natural gas / 300 kW LPG stationary standby generator. PSI 21.9L V12 high-output turbocharged engine, Stamford HCI534 alternator, Deep Sea Electronics controller. Made in USA.
3-phasecommercialhotel
Gillette
Gillette SP-6500
Factory-direct. PSI 31.8L V12 engine + Deep Sea controller — no proprietary lock-in. 3-7 day lead times.
650 kW standby · Natural Gas / LPG · Liquid-cooled
650 kW natural gas standby for data centers, hospitals, industrial facilities, and campus-scale emergency backup.
650 kW natural gas stationary standby generator. PSI 31.8L V12 turbocharged engine, Stamford alternator, Deep Sea Electronics controller. Standby rating published for natural gas. Made in USA.
3-phasedata-centerhospital
Gillette
Gillette SP-8000
Factory-direct. PSI 39.2L V12 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
800 kW standby · Natural Gas · Liquid-cooled
800 kW natural gas standby for data centers, hospitals, industrial campuses, and large municipal facilities.
800 kW natural gas stationary standby generator. PSI 39.2L V12 turbocharged engine, Stamford HCI634 alternator, DSE 7420 MKII. Standby rating published for natural gas. Made in USA.
3-phasedata-centerhospital
Gillette
Gillette SPHD-9000
Factory-direct. Hyundai 21.9L V12 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
900 kW standby · Diesel · Liquid-cooled
900 kW diesel standby for data centers, hospitals, industrial campuses, and large-scale critical infrastructure.
900 kW stationary diesel standby generator with Hyundai DP222CCS V12 engine. Made-in-USA with Stamford S6DD311 alternator, shunt excitation, and DSE 7420 MKII controller.
1,000 kW (1 MW) diesel standby for data centers, hospitals, industrial campuses, and utility-scale backup.
1,000 kW stationary diesel standby generator with Mitsubishi S12H engine. USA factory built with Stamford AVK alternator, PMG excitation, and DSE 7420 MKII controller.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPMI-2M
Factory-direct 2 MW diesel. Mitsubishi S16R V16. No proprietary lock-in.
2 MW standby · Diesel · Liquid-cooled
2,000 kW (2 MW) diesel standby for hyperscale data centers, hospitals, industrial campuses, and utility-grade backup.
Factory-direct. Mitsubishi S12A2 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for data centers, hospitals, industrial campuses, and large-scale critical infrastructure.
800 kW stationary diesel standby generator with Mitsubishi S12A2 engine. USA factory built with Stamford AVK HCI634H alternator, PMG excitation, and DSE 7420 MKII controller.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPVD-5000
Factory-direct. Volvo Penta 16.1L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for data centers, hospitals, industrial campuses, and large municipal facilities.
600 kW Tier 4 Final diesel for data centers, hospitals, and industrial prime power.
600 kW standby / 570 kW prime Tier 4 Final diesel generator with Volvo Penta TWD1683GE 16.1L engine. H2O-to-air aftercooled, SCR+DEF.
Tier 4 Final3-phasedata-centerhospital
Kohler
Kohler 1000REOZMD
1020 kW diesel standby -- Mitsubishi S12H-Y2PTAW-1, sub-3% THD. Decision-Maker controller for load management and paralleling.
1.0 MW standby · Diesel · Liquid-cooled
1 MW industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
1020 kW diesel industrial standby generator powered by Mitsubishi. Large-frame REOZ for data centers, hospitals, and mission-critical facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 1250REOZMD
1280 kW diesel standby -- Mitsubishi S12R-Y2PTAW-1, sub-3% THD. Decision-Maker controller for load management and paralleling.
1.3 MW standby · Diesel · Liquid-cooled
1280 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
1280 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 1250ROZMC
1280 kW diesel standby -- Mitsubishi S12R V12 turbo, sub-3% THD. Decision-Maker controller for load management and paralleling.
1.3 MW standby · Diesel · Liquid-cooled
1280 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
1280 kW diesel 1800 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
3-phasedata-centerhealthcare
Kohler
Kohler 1600REOZMD
1600 kW industrial diesel -- Mitsubishi S16R-Y2PTAW-1, offered with the APM603 or Decision-Maker 6000 paralleling controller. Sub-3% THD, UL 2200, NFPA 110 Level 1.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1600 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 1600ROZMC
1600 kW industrial diesel -- Mitsubishi S16R V16 turbo, offered with the APM603 or Decision-Maker 6000 paralleling controller. Sub-3% THD, UL 2200, NFPA 110 Level 1.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1600 kW diesel 1800 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
3-phasedata-centerhealthcare
Kohler
Kohler 1750REOZMD
1.8 MW standby · Diesel · Liquid-cooled
1780 kW diesel industrial generator powered by Mitsubishi.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 2000REOZMD
2000 kW industrial diesel -- Mitsubishi S16R-Y2PTAW2-1 with Decision-Maker 6000 paralleling. UL 2200, NFPA 110 Level 1.
2 MW standby · Diesel · Liquid-cooled
2000 kW industrial standby for data centers, hospitals, and utility-scale facilities.
2000 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
2000 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
2000 kW diesel 1800 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
3-phasedata-centerhealthcare
Kohler
Kohler 2500REOZDC
2500 kW industrial diesel -- Detroit Diesel/MTU 16V4000G83L with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
2500 kW diesel industrial generator powered by Detroit Diesel/MTU. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 500REOZJ
500 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
500 kW standby · Diesel · Liquid-cooled
500 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
500 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REOZJB
510 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
510 kW standby · Diesel · Liquid-cooled
510 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
510 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REOZJC
505 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Offered with the APM402, APM603 or Decision-Maker 6000 controller; the APM603 and Decision-Maker 6000 support paralleling.
505 kW standby · Diesel · Liquid-cooled
505 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
505 kW diesel commercial standby generator. Large institutional diesel for hospitals, data centers, high-rises, and mission-critical facilities.
Tier 23-phasehospitaldata-center
Kohler
Kohler 500REOZVC
515 kW standby · Diesel · Liquid-cooled
515 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
515 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REZK
500 kW industrial gaseous -- Siemens SGE-24SL with PM alternator, sub-3% THD. No fuel tank, no SPCC, lower emissions than diesel.
500 kW standby · Natural Gas · Liquid-cooled
500 kW gaseous standby for large commercial, industrial, and campus applications where NG eliminates diesel logistics and permitting.
490-500 kW natural gas industrial standby generator with Siemens engine and Brushless Permanent-Magnet Pilot Exciter alternator. Large commercial and industrial backup power.
3-phasecommercialhealthcare
Kohler
Kohler 500REZXD
500 kW industrial gaseous -- PSI/Doosan D219L with PM alternator, sub-3% THD. No fuel tank, no SPCC, lower emissions than diesel.
500 kW standby · LPG · Liquid-cooled
500 kW gaseous standby for large commercial, industrial, and campus applications where NG eliminates diesel logistics and permitting.
500 kW LPG industrial standby generator. Enclosed gaseous standby with PSI/Doosan engine and pilot-excited permanent-magnet alternator.
3-phasecommercialhealthcare
Kohler
Kohler 550REOZVB
550 kW diesel standby -- Volvo TAD1642GE-B, sub-3% THD. Decision-Maker controller for load management and paralleling.
550 kW standby · Diesel · Liquid-cooled
550 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
550 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 600REOZVB
600 kW standby · Diesel · Liquid-cooled
600 kW diesel commercial/industrial standby generator powered by Volvo.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 750REOZMD
760 kW diesel standby -- Mitsubishi S12A2-Y2PTAW-2, sub-3% THD. Decision-Maker controller for load management and paralleling.
760 kW standby · Diesel · Liquid-cooled
760 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
760 kW diesel commercial/industrial standby generator powered by Mitsubishi. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler
Kohler 800REOZMD
Standby: see spec sheet · Diesel · Liquid-cooled
Diesel industrial standby generator powered by Mitsubishi.
3-phasedata-centerhealthcare
Kohler
Kohler 900REOZMD
Standby: see spec sheet · Diesel · Liquid-cooled
diesel industrial standby generator.
3-phasedata-centerhealthcare
Kohler
Kohler KD1000
Megawatt-class KD at 1000 kW -- Kohler KD27V12, APM603 or APM802 controller.
1 MW standby · Diesel · Liquid-cooled
1000 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1000 kW diesel industrial standby generator. Megawatt-class KD Series unit for data centers, hospitals, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD1250-4
Megawatt-class KD at 1250 kW -- Kohler KD36V16, APM603 controller.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
Megawatt-class KD at 1250 kW -- Kohler KD36V16, APM603 or APM802 controller.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1250 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD1350
1.4 MW standby · Diesel · Liquid-cooled
1350 kW diesel industrial standby generator. KD Series platform.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD1500
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel industrial standby generator. KD Series platform.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD1600
Megawatt-class KD at 1600 kW -- Kohler KD45V20, APM603 or APM802 controller.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1600 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and heavy industrial applications.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD1750
Megawatt-class KD at 1750 kW -- Kohler KD45V20, APM603 or APM802 controller.
1.8 MW standby · Diesel · Liquid-cooled
1750 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1750 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2000
2000 kW KD Series -- Kohler KD62V12 with PM pilot exciter.
2 MW standby · Diesel · Liquid-cooled
2000 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2000 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure requiring multi-megawatt backup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2250
2.3 MW standby · Diesel · Liquid-cooled
2250 kW diesel industrial standby generator. KD Series platform.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2500
2500 kW KD Series -- Kohler KD62V12 with PM pilot exciter.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2500 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and heavy industrial facilities requiring 2+ MW backup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2500-4
2500 kW KD Series -- Kohler KD62V12 with PM pilot exciter.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
800 kW diesel standby — MTU 2000-series V12, 23.9L. Medium-voltage 4,160V option, EUP injection, separate intercooler circuit, 59 gph.
800 kW standby · Diesel · Liquid-cooled
Industrial/hospital standby at 800 kW.
800 kW diesel standby generator with MTU 12V2000G85TB 23.9L V12 engine, EPA Tier 2, 208–4160V including medium voltage, electronic unit pump injection, ADEC governor. 4675 x 2292 x 2341 mm, 17,379 lb.
Tier 23-phasecommercial-standbyindustrial-standby
MTU
MTU 12V4000 DS1250
1,250 kW standby. MTU 57.2L V12, 380-13,800V, HVO and GtL fuels meeting EN15940.
1.3 MW standby · Diesel · Liquid-cooled
Standby power at 1,250 kW. Diesel at 90 gph at full load, 9 voltage configs to 13.8kV, SCAQMD + Tier 2.
1,250 kW standby diesel generator from MTU (Rolls-Royce). 57.2L V12 engine, EPA Tier 2 + SCAQMD, 380-13,800V.
Tier 23-phasedata-centerhospital-large
MTU
MTU 12V4000 DS1500
1,500 kW standby. MTU 57.2L V12, 380-13,800V, HVO and GtL fuels meeting EN15940.
1.5 MW standby · Diesel · Liquid-cooled
Standby power at 1,500 kW. Diesel at 111 gph at full load, 9 voltages to 13.8kV, HVO compatible.
1,500 kW standby diesel generator from MTU (Rolls-Royce). 57.2L V12 engine, EPA Tier 2 + SCAQMD, 380-13,800V.
Standby power at 2.5 MW. Diesel at 183 gph at full load, standby-only rating.
2,500 kW standby diesel generator from MTU (Rolls-Royce). 76.3L V16 engine, EPA Tier 2 + SCAQMD, 380-13,800V. 16-cylinder Series 4000.
Tier 23-phasedata-centerhospital-large
MTU
MTU 20V4000 DS2800
2,800 kW diesel standby — MTU 20V4000 95.4L V20.
2.8 MW standby · Diesel · Liquid-cooled
Utility-scale standby at 2.8 MW. Diesel at 186 gph, 480V-13.8kV direct MV connection, 62,000 lb installation.
2800 kW diesel standby generator with MTU 20V4000G83 95.4L 20-cylinder V common-rail engine, EPA Tier 2, 380V–13.8kV including medium voltage, ADEC governor, 7626 x 3099 x 3569 mm, 62,056 lb.
Tier 23-phasecommercial-standbyindustrial-standby
MTU
MTU 20V4000 DS3250
3,250 kW diesel standby — top of the MTU product line. 95.4L V20 at 3,490 kWm, 480V-13.8kV, standby-only, 223 gph.
3.3 MW standby · Diesel · Liquid-cooled
Maximum single-unit standby at 3.25 MW. Diesel at 223 gph, 480V-13.8kV medium-voltage, 65,000+ lb power plant.
3250 kW diesel standby generator with MTU 20V4000G83L 95.4L 20-cylinder V common-rail engine, EPA Tier 2, 480V–13.8kV medium and high voltage, ADEC governor. 7766 x 3099 x 3569 mm, 65,369 lb.
Tier 23-phasecommercial-standbyindustrial-standby
Need service for the Thomson TS880 Automatic Transfer Switch?
Our technicians work on every major component OEM. We stock common parts and source rare ones.