Deep Sea Electronics · DSE 7000 Series (Networked AMF)

New

DSE 7420 MkII

Controllers

Networked auto mains failure controller with embedded Ethernet, SNMP, and web server. The standard for BMS-integrated commercial standby generators.

Overview#

The DSE 7420 MkII is a networked auto mains failure (AMF) generator controller — the "connected" evolution of the DSE 7320. While the 7320 is the industry workhorse for standalone standby, the 7420 adds native Ethernet with embedded web server, Modbus TCP, and SNMP v2c — making it the standard for generators that need to integrate directly with building management systems over IP networks.

In data centers, hospitals, and modern commercial buildings where everything connects to the BMS, the 7420 eliminates the need for external protocol gateways or add-on communication modules.

7420 vs 7320: when to choose which#

FeatureDSE 7320DSE 7420 MkII
Serial (RS232/RS485)
USB
Ethernet
Modbus TCP
SNMP v2c
Embedded web server
PriceLowerHigher
Use caseSimple standbyBMS-integrated standby

Choose 7320 when: standalone operation, no network integration needed, cost-sensitive. Choose 7420 when: BMS integration required, IT monitoring tools (SNMP), remote web-based diagnostics.

BMS integration scenarios#

The 7420's native protocols cover every common BMS integration:

Our service experience#

The 7420 MkII is our standard recommendation for new commercial standby installations where the facility has a BMS. The embedded web server is invaluable for remote diagnostics — we can check controller status, read fault codes, and verify exercise history from our office before dispatching a technician. This reduces unnecessary site visits and speeds up troubleshooting. Configuration is done via DSE Configuration Suite (same software as the 7320 — no separate training needed).

Frequently Asked Questions

What's the difference between the DSE 7420 and 7320?
The 7420 MkII adds native Ethernet connectivity: embedded web server, Modbus TCP, and SNMP v2c — none of which exist on the 7320. The 7320 has only RS232/RS485/USB for communication. Choose the 7420 when the generator needs to integrate with a building management system (BMS) over the facility's IP network.
Does the 7420 support paralleling?
No — the 7420 is a single-genset auto mains failure controller. For paralleling, you need the DSE 8610 MkII (genset side) + DSE 8660 MkII (mains side). The 7420 is designed for standalone standby generators that start on mains failure and transfer load via an ATS.
What is SNMP and why does it matter for generators?
SNMP (Simple Network Management Protocol) allows the generator controller to be monitored by the same IT tools used for network equipment (Nagios, PRTG, SolarWinds). In data centers, this means the generator appears alongside servers, switches, and UPS in a unified monitoring dashboard — rather than requiring a separate generator-specific monitoring system.
Can the 7420 be monitored remotely without DSEWebNet?
Yes — the embedded web server provides a browser-based interface accessible from any device on the same network. SNMP sends alerts to any SNMP manager. Modbus TCP integrates with any SCADA system. DSEWebNet (cloud) is an additional option but not required for remote visibility.

Found in these gensets

Generator models that ship with or are commonly paired with the DSE 7420 MkII.

Gillette

New

Gillette PR-1000

100 kW standby · Natural Gas · Liquid-cooled

100 kW prime-rated natural gas generator. PSI 8.1L I6 turbocharged, Stamford UCI274E alternator, DSE 7420 MKII. Continuous duty. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette PR-1300

130 kW standby · Natural Gas · Liquid-cooled

130 kW prime-rated natural gas generator. PSI 8.1L I6 turbocharged, Stamford UCI274F alternator, DSE 7420 MKII. Continuous duty. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette PR-1800

180 kW standby · Natural Gas · Liquid-cooled

180 kW prime-rated natural gas generator. PSI 11.1L I6 turbocharged, Stamford UCID274J alternator, DSE 7420 MKII. Continuous duty. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette PR-2400

240 kW standby · Natural Gas · Liquid-cooled

240 kW prime-rated natural gas generator. PSI 14.6L V8 turbocharged, Stamford S4L1DD alternator, DSE 7420 MKII. Continuous duty, 3-phase only. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette PR-3500

350 kW standby · Natural Gas · Liquid-cooled

350 kW prime-rated natural gas generator. PSI 21.9L V12 turbocharged, Stamford S4L1DG alternator, DSE 7420. Continuous duty, 3-phase only. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette PR-5400

540 kW standby · Natural Gas · Liquid-cooled

540 kW prime-rated natural gas generator. PSI 31.8L V12 turbocharged, Stamford HCI534 alternator, DSE 7420. Continuous duty, 3-phase only. Gillette's largest prime gas unit.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette PR-800

80 kW standby · Natural Gas / LPG · Liquid-cooled

80 kW prime-rated natural gas / LPG generator. PSI 8.8L V8 naturally aspirated, Stamford UCI274 alternator, DSE 7420 MKII. Continuous duty. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site
Gillette SP-1500 backup generator

Gillette

New

Gillette SP-1500

150 kW standby · Natural Gas / LPG · Liquid-cooled

150 kW natural gas / 130 kW LPG stationary standby generator. Made-in-USA commercial gaseous unit with PSI 8.8L turbocharged V8 engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialhealthcare

Gillette

New

Gillette SP-1M

1.1 MW standby · Natural Gas · Liquid-cooled

1,050 kW natural gas stationary standby generator. PSI 52.3L V16 turbocharged engine, Stamford AVK alternator, DSE 7420 MKII. Natural gas only. Made in USA.

EPA Stationary Spark Ignition3-phasedata-centerhospital

Gillette

New

Gillette SP-2000P

200 kW standby · Natural Gas · Liquid-cooled

200 kW natural gas stationary standby generator. Made-in-USA commercial unit with PSI 8.8L high-output turbocharged V8, Stamford alternator, and DSE 7420 MKII controller. NG only.

EPA Stationary Spark Ignition3-phasecommercialhotel
Gillette SP-250 backup generator

Gillette

New

Gillette SP-250

25 kW standby · Natural Gas / LPG · Liquid-cooled

25 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 2.4L inline-4 engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant
Gillette SP-2500P backup generator

Gillette

New

Gillette SP-2500P

250 kW standby · Natural Gas / LPG · Liquid-cooled

250 kW natural gas / 165 kW LPG stationary standby generator. PSI 13L inline-6 turbocharged engine, Stamford S4L1D alternator, DSE 7420 MKII. Made in USA.

EPA Stationary Spark Ignition3-phasecommercialhotel

Gillette

New

Gillette SP-3000P

300 kW standby · Natural Gas / LPG · Liquid-cooled

300 kW natural gas / 165 kW LPG stationary standby generator. PSI 13L inline-6 high-output turbocharged engine, Stamford S4L1D alternator, DSE 7420 MKII. Made in USA.

EPA Stationary Spark Ignition3-phasecommercialhotel
Gillette SP-3500 backup generator

Gillette

New

Gillette SP-3500

350 kW standby · Natural Gas / LPG · Liquid-cooled

350 kW natural gas / 210 kW LPG stationary standby generator. PSI 14.6L V8 turbocharged engine, Stamford S4L1DF alternator, DSE 7420 MKII. Made in USA.

EPA Stationary Spark Ignition3-phasecommercialhotel
Gillette SP-4000 backup generator

Gillette

New

Gillette SP-4000

400 kW standby · Natural Gas / LPG · Liquid-cooled

400 kW natural gas / 300 kW LPG stationary standby generator. PSI 21.9L V12 turbocharged engine, Stamford S4L1DG alternator, DSE 7420 MKII. Made in USA.

EPA Stationary Spark Ignition3-phasecommercialhotel
Gillette SP-410 backup generator

Gillette

New

Gillette SP-410

40 kW standby · Natural Gas / LPG · Liquid-cooled

40 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 4.3L V6 engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant
Gillette SP-5000 backup generator

Gillette

New

Gillette SP-5000

500 kW standby · Natural Gas / LPG · Liquid-cooled

500 kW natural gas / 300 kW LPG stationary standby generator. PSI 21.9L V12 high-output turbocharged engine, Stamford HCI534 alternator, DSE 7420 MKII. Made in USA.

EPA Stationary Spark Ignition3-phasecommercialhotel
Gillette SP-620 backup generator

Gillette

New

Gillette SP-620

60 kW standby · Natural Gas / LPG · Liquid-cooled

60 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 5.7L V8 engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant
Gillette SP-6500 backup generator

Gillette

New

Gillette SP-6500

650 kW standby · Natural Gas · Liquid-cooled

650 kW natural gas stationary standby generator. PSI 31.8L V12 turbocharged engine, Stamford HCI634 alternator, DSE 7420 MKII. Natural gas only. Made in USA.

EPA Stationary Spark Ignition3-phasedata-centerhospital

Gillette

New

Gillette SP-960

96 kW standby · Natural Gas / LPG · Liquid-cooled

96 kW natural gas / 80 kW LPG stationary standby generator. Made-in-USA commercial gaseous unit with PSI engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant

Gillette

New

Gillette SPD-1000

100 kW standby · Diesel · Liquid-cooled

100 kW stationary diesel standby generator with Perkins 1104D-E44TAG2 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialtelecom

Gillette

New

Gillette SPD-1500

150 kW standby · Diesel · Liquid-cooled

150 kW stationary diesel standby generator with Perkins 1106D-E70TAG4 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialhospital

Gillette

New

Gillette SPD-2000

200 kW standby · Diesel · Liquid-cooled

200 kW stationary diesel standby generator with Perkins 1106D-E70TAG5 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialhospital

Gillette

New

Gillette SPD-300

30 kW standby · Diesel · Liquid-cooled

30 kW stationary diesel standby generator with Perkins 404D-22TAG engine. Made-in-USA commercial diesel unit with Stamford alternator and DSE 7420 MKII controller.

Tier 4 Interim3-phasecommercialtelecom

Gillette

New

Gillette SPD-600

60 kW standby · Diesel · Liquid-cooled

60 kW stationary diesel standby generator with Perkins 1104D-E44TG1 engine. Made-in-USA with Stamford UCI224F alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialtelecom

Gillette

New

Gillette SPHD-9000

900 kW standby · Diesel · Liquid-cooled

900 kW stationary diesel standby generator with Hyundai DP222CCS V12 engine. Made-in-USA with Stamford S6DD311 alternator, shunt excitation, and DSE 7420 MKII controller.

Tier 23-phasedata-centerhospital

Gillette

New

Gillette SPJD-1000

100 kW standby · Diesel · Liquid-cooled

100 kW stationary diesel standby generator with John Deere 4045HF285 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialtelecom

Gillette

New

Gillette SPJD-1550

155 kW standby · Diesel · Liquid-cooled

155 kW stationary diesel standby generator with John Deere 6068HF285 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialhospital

Gillette

New

Gillette SPJD-2100

210 kW standby · Diesel · Liquid-cooled

210 kW stationary diesel standby generator with John Deere 6068HF485 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.

Tier 33-phasecommercialhospital

Gillette

New

Gillette SPJD-600

60 kW standby · Diesel · Liquid-cooled

60 kW stationary diesel standby generator with John Deere engine. Made-in-USA commercial diesel unit with DSE controller and Stamford or Marathon alternator.

Tier 33-phasecommercialtelecom

Gillette

New

Gillette SPMI-1.5M

1.5 MW standby · Diesel · Liquid-cooled

1,500 kW stationary diesel standby generator with Mitsubishi S16R V16 engine. 65.37L displacement, Stamford AVK S7L1D alternator, PMG excitation. Made in USA.

Tier 23-phasedata-centerhospital

Gillette

New

Gillette SPMI-1M

1 MW standby · Diesel · Liquid-cooled

1,000 kW stationary diesel standby generator with Mitsubishi S12H engine. Made-in-USA with Stamford AVK S6D alternator, PMG excitation, and DSE 7420 MKII controller.

Tier 23-phasedata-centerhospital

Gillette

New

Gillette SPMI-2M

2 MW standby · Diesel · Liquid-cooled

2,000 kW stationary diesel standby generator with Mitsubishi S16R V16 engine. 65.37L displacement, Stamford AVK S7L1DG alternator, PMG excitation. Gillette's largest unit.

Tier 23-phasedata-centerhospital

Gillette

New

Gillette SPMI-8000

800 kW standby · Diesel · Liquid-cooled

800 kW stationary diesel standby generator with Mitsubishi S12A2 engine. Made-in-USA with Stamford AVK HCI634 alternator, PMG excitation, and DSE 7420 MKII controller.

Tier 23-phasedata-centerhospital

Need service for the DSE 7420 MkII?