Best cold-weather performance — rated to -40F, the default choice for harsh climates
10-15% cheaper than CAT at comparable power ratings in the 200-1,500 kW range
Who Cummins is for
200-1,500 kW commercial and mission-critical applications, cold-climate installations, and buyers who want single-source accountability with no finger-pointing between engine, alternator, and controls vendors.
What to consider before specifying Cummins
*Dealer network thinner than Generac (~2,000 vs 10,000+)
*Premium parts pricing despite competitive unit pricing
*Over-engineered enclosures can complicate field repairs
Cummins is the only major generator manufacturer that controls its entire power chain — engine, alternator, controls, and automatic transfer switch — all designed and built in-house. That vertical integration eliminates the component-mismatch issues that can arise when a packager pairs one company's engine with another's alternator and a third party's controls. When something goes wrong with a Cummins unit, one manufacturer owns the warranty. For facility managers who have experienced the frustration of an engine maker and a packager blaming each other during a warranty claim, that single point of accountability is worth the specification.
Performance numbers back up the engineering. Cummins units accept 100% load in 10 seconds, which is critical for healthcare and data center applications where transfer time directly impacts uptime SLAs. The QuietConnect enclosure line runs at 62-67 dB, keeping noise within conversation-level range. And for cold-climate installations, Cummins is unmatched: factory block heater packages support cold starts at -40F, the lowest rating among major brands. These specs, combined with pricing that typically runs 10-15% below Caterpillar for comparable output, make Cummins the value leader in the industrial segment.
Where Cummins falls short is power quality and resale. Total harmonic distortion runs in the 5-8% industry-standard range — adequate for most commercial applications but not competitive with Kohler's sub-3% for hospitals and sensitive electronics. Resale values also trail Caterpillar by a meaningful margin; a five-year-old Cummins unit will not command the same secondary market price as an equivalent CAT. For buyers who plan to own and operate for the full useful life of the generator, that resale gap is irrelevant. For those who cycle equipment, it is a real cost.
Frequently asked questions
How quiet are Cummins QuietConnect generators?
QuietConnect enclosures produce 62-67 dB at rated load, which is comparable to normal conversation volume. This is quieter than most open-frame industrial units but not as quiet as Kohler's premium enclosures at equivalent power ratings.
What is the advantage of Cummins vertical integration?
Cummins manufactures its own engines, alternators, control systems, and automatic transfer switches. When a warranty issue arises, there is one company responsible — no finger-pointing between an engine manufacturer and a packager. This also means tighter integration between components, which contributes to the 10-second load acceptance and cold-start reliability.
What are the cold-weather specifications?
Cummins generators are rated for cold starts at -40F (-40C) with factory block heater packages, the lowest cold-start rating among major brands. Combined with 100% load acceptance in 10 seconds, this makes Cummins the standard specification for data centers, telecom sites, and utilities in northern climates.
Key specs at a glance
Power range
13–3500 kW standby
Fuel types
diesel, natural-gas, lpg
Engine OEMs
Cummins, Kubota
Alternator OEMs
Phase options
1-phase, 3-phase
Models in library
84
When to Specify Cummins
✓Industry-leading paralleling capability with PowerCommand controllers — ideal for data centers and facilities requiring N+1 redundancy
✓Only brand with full vertical integration across engine, alternator, controls, AND transfer switch built in-house
✓Broadest product range from 25kW to 3.5MW covers residential through megawatt-class industrial
✓Best cold-weather performance — rated to -40F, the default choice for harsh climates
✓Best choice when paralleling, scalability, single-source accountability, or a single-brand fleet strategy is the priority
100 kW diesel with full Cummins vertical integration. 100% load acceptance in 10 seconds. Single-source warranty.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for office complexes, hotels, and commercial buildings requiring fast load pickup.
100 kW EPA Tier 3 diesel standby generator with QSB5-G13 engine and PowerCommand 2.3 control. Sound-attenuated aluminum enclosure, UL 2200 listed, NFPA 110 Level 1 capable.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C100 N6
100 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel logistics.
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby for hotels, office campuses, and healthcare clinics with gas service.
100 kW natural gas standby generator with QSJ5.9G-G3 engine. 100 kW / 125 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified. Dry weight 2812 lbs.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1000 D6
1 MW diesel with QST30 V-12 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure requiring megawatt-class power.
1000 kW diesel standby generator with QST30 30L V-12 engine. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications requiring megawatt-class power.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1000 N6
1000 kW natural gas with full Cummins vertical integration. QSK60G engine. Paralleling for multi-MW gas installations.
1 MW standby · Natural Gas · Liquid-cooled
1000 kW natural gas standby for Tier III data centers, large campuses, and utility peak shaving on gas.
1000 kW natural gas standby powered by the QSK60G. NFPA 110 Type 10 capable for mission-critical facilities without diesel infrastructure.
1 MW standby · Natural Gas / LPG · Liquid-cooled
1000 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and mission-critical facilities requiring NFPA 110 Type 10 compliance.
1000 kW natural gas standby generator with QSK60G engine. 1000 kW / 1250 kVA standby, NFPA 110 Type 10 capable, PowerCommand controls, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1100 D6
1100 kW diesel with QSK38 V-12 engine. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.
1.1 MW standby · Diesel · Liquid-cooled
1100 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure requiring above-megawatt power.
1100 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1100 N6
1100 kW natural gas standby powered by the QSK60G. High-output megawatt-class gas power without diesel fuel infrastructure.
1.1 MW standby · Natural Gas / LPG · Liquid-cooled
1100 kW natural gas standby for hospitals, data centers, large campuses, and industrial facilities with natural gas service.
1100 kW natural gas standby generator with QSK60G gas engine. 1100 kW / 1375 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C125 D6
125 kW diesel with Cummins QSB5-G6 engine. Top of the QSB5 4-cylinder range. 100% load acceptance in 10 seconds. Single-source warranty.
125 kW standby · Diesel · Liquid-cooled
125 kW diesel standby for hotels, office complexes, and commercial buildings requiring fast load pickup in a compact 4-cylinder package.
125 kW EPA Tier 3 diesel standby generator with Cummins QSB5-G6 engine and PowerCommand 1.1 control. Sound-attenuated aluminum enclosure, UL 2200 listed, NFPA 110 Level 1 capable.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C125 N6
125 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Single-source warranty.
125 kW standby · Natural Gas · Liquid-cooled
125 kW natural gas standby for mid-size commercial, schools, and healthcare facilities on gas mains.
125 kW natural gas standby generator with QSJ8.9G engine. 125 kW standby, PowerCommand 2.3 controls, UL 2200, IBC Seismic, NFPA 110 capable. Quiet Connect RS125 series, weight 3915 lbs.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1250 D6
1250 kW diesel with QSK38 V-12 engine at full rated output. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure.
1250 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, 2P2L cooling, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1250 D6e
1.25 MW Centum Series with QSK38 engine. Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins premium platform.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW Centum diesel standby for data centers, hospitals, and mission-critical facilities requiring premium reliability with reduced footprint.
1250 kW Centum Series diesel standby generator with QSK38 engine. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center and mission-critical applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1250 N6
1250 kW natural gas standby powered by the QSV91G. High-capacity gas power for mission-critical facilities without diesel infrastructure.
1.3 MW standby · Natural Gas / LPG · Liquid-cooled
1250 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and industrial facilities with natural gas service.
1250 kW natural gas standby generator with QSV91G gas engine. 1250 kW / 1563 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1300 N6
1300 kW natural gas standby powered by the QSK60G. NFPA 110 Type 10 capable for mission-critical facilities at the top of QSK60G output range.
1.3 MW standby · Natural Gas / LPG · Liquid-cooled
1300 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and mission-critical facilities requiring NFPA 110 Type 10 compliance.
1300 kW natural gas standby generator with QSK60G engine. 1300 kW / 1625 kVA standby, NFPA 110 Type 10 capable, PowerCommand controls, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1400 N6c
1400 kW natural gas standby powered by the QSV91G. High-capacity megawatt-class gas power for mission-critical facilities.
1.4 MW standby · Natural Gas / LPG · Liquid-cooled
1400 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and industrial facilities with natural gas service.
1400 kW natural gas standby generator with QSV91G gas engine. 1400 kW / 1750 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C150 D6
150 kW diesel with full Cummins vertical integration. 100% load acceptance in 10 seconds. 10-15% below CAT pricing.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hotels, warehouses, and mid-size commercial requiring fast load transfer.
150 kW EPA Tier 3 diesel standby generator with QSB7-G5 inline-6 engine and PowerCommand 1.1 control. NFPA 110 Level 1 compliant, UL 2200 listed, sound-attenuated aluminum enclosure.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C150 N6
150 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel permitting needed.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas standby for hotels, large retail, and commercial campuses with gas service.
150 kW natural gas/propane standby generator with Cummins QSJ8.9G 8.9L turbocharged inline-6 engine. PowerCommand control, UL 2200 listed, NFPA 110 Level 1 capable. Wet weight 1,776 kg (3,915 lbs).
1500 kW diesel with QSK50 V-16 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3512.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants requiring maximum single-unit power.
1500 kW diesel standby generator with QSK50 50.3L V-16 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, 2P2L cooling, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1500 D6e
1.5 MW Centum Series with QSK38 at peak output. Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins platform.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW Centum diesel standby for data centers, hospitals, and mission-critical facilities requiring premium reliability with reduced footprint.
1500 kW Centum Series diesel standby generator with QSK38 engine. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center and mission-critical applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1540 N6c
1540 kW natural gas standby powered by the QSV91G at its top-end gas rating. Maximum QSV91G output without diesel infrastructure.
1.5 MW standby · Natural Gas / LPG · Liquid-cooled
1540 kW natural gas standby for hospitals, Tier III+ data centers, large campuses, and industrial facilities with natural gas service.
1540 kW natural gas standby generator with QSV91G gas engine. 1540 kW / 1925 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C175 D6
175 kW diesel with Cummins QSB7-G5 inline-6 engine. Full Cummins vertical integration. 100% load acceptance in 10 seconds.
175 kW standby · Diesel · Liquid-cooled
175 kW diesel standby for hotels, office complexes, and mid-size commercial buildings requiring substantial emergency power capacity.
175 kW EPA Tier 3 diesel standby generator with Cummins QSB7-G5 inline-6 engine and PowerCommand 1.1 control. Sound-attenuated aluminum enclosure, NFPA 110 Level 1 capable, UL 2200 listed.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C175 N6
175 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel infrastructure.
175 kW standby · Natural Gas · Liquid-cooled
175 kW natural gas standby for schools, mid-size hotels, and commercial campuses on gas mains.
175 kW natural gas standby generator with GTA 8.3G engine. 175 kW / 219 kVA standby, PowerCommand 1.1 controls, 2202 CFH full-load, dimensions 115 x 40 x 59 in. ISO 9001:2015 manufactured.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C1750 D6e
1.75 MW Centum Series with QSK50 engine (launched 2024). Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins platform.
1.8 MW standby · Diesel · Liquid-cooled
1750 kW Centum diesel standby for data centers and mission-critical facilities requiring premium reliability with reduced footprint.
1750 kW Centum Series diesel standby generator with QSK50 engine, launched 2024. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C1750 N6cb
1750 kW natural gas standby powered by the HSK78G. Near-2-MW gas power for mission-critical facilities without diesel infrastructure.
1.8 MW standby · Natural Gas / LPG · Liquid-cooled
1750 kW natural gas standby for large hospitals, hyperscale data centers, major campuses, and industrial facilities with utility-grade gas service.
1750 kW natural gas standby generator with HSK78G gas engine. 1750 kW / 2188 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C20 D6
20 kW diesel standby with Cummins-integrated controls and sound-attenuated enclosure. Compact footprint for tight installations.
20 kW standby · Diesel · Liquid-cooled
20 kW diesel standby for small offices, retail locations, and light commercial buildings requiring backup power.
20 kW EPA Tier 4 Interim diesel standby generator with Kubota V2203M engine and PowerCommand 1.1 control. Sound-attenuated enclosure, liquid-cooled, for small commercial and residential standby applications.
2 MW diesel with QSK60 V-16 engine. Full Cummins vertical integration. Paralleling for multi-MW arrays. Proven mega-diesel platform.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for Tier III/IV data centers, large industrial facilities, and mission-critical infrastructure requiring multi-megawatt power.
2000 kW diesel standby generator with QSK60 60L V-16 engine. PowerCommand control, liquid-cooled, for data center, industrial, and mission-critical standby applications requiring multi-megawatt power.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C2000 D6e
2 MW Centum Series with QSK50 engine (launched 2024). Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins platform.
2 MW standby · Diesel · Liquid-cooled
2000 kW Centum diesel standby for data centers and mission-critical facilities requiring 2 MW premium standby power with reduced footprint.
2000 kW Centum Series diesel standby generator with QSK50 engine, launched 2024. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C2000 N6c
2000 kW natural gas standby -- the largest gas generator in the Cummins lineup. Full 2 MW single-unit gas power for the most demanding mission-critical facilities.
2 MW standby · Natural Gas / LPG · Liquid-cooled
2000 kW natural gas standby for large hospitals, hyperscale data centers, major campuses, and heavy industrial facilities with utility-grade gas service.
2000 kW natural gas standby generator with HSK78G gas engine. 2000 kW / 2500 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified. Largest gas generator in the Cummins lineup.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C2250 D6
2.25 MW diesel with QSK60 V-16 engine. Mid-range of the QSK60 platform. Full Cummins vertical integration. Paralleling for multi-MW arrays.
2.3 MW standby · Diesel · Liquid-cooled
2250 kW diesel standby for Tier III/IV data centers, large industrial facilities, and mission-critical infrastructure.
2250 kW diesel standby generator with QSK60 60L V-16 engine. PowerCommand control, liquid-cooled, for data center, industrial, and mission-critical standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C25 D6
25 kW diesel with Cummins 4BT3.3 engine and integrated controls. Compact enclosure for tight installations. Single-source warranty.
25 kW standby · Diesel · Liquid-cooled
25 kW diesel standby for small offices, retail spaces, and light commercial buildings requiring reliable backup power.
25 kW EPA Tier 3 diesel standby generator with Cummins 4BT3.3-G5 engine and PowerCommand 1.1 control. Sound-attenuated enclosure, liquid-cooled, for small commercial standby applications.
Tier 33-phasecommercial-standbysmall-office
Cummins
Cummins C250 D6
250 kW diesel with Cummins QSL9-G7 engine and HPCR fuel system. PowerCommand 2.3 control with AmpSentry protection. Single-source warranty.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, data centers, and large commercial buildings requiring substantial emergency power with fast load acceptance.
250 kW EPA Tier 3 diesel standby generator with Cummins QSL9-G7 inline-6 engine and PowerCommand 2.3 control. HPCR fuel system, sound-attenuated enclosure, for commercial and industrial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C250 N6
250 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel logistics.
250 kW standby · Natural Gas · Liquid-cooled
250 kW natural gas standby for hospitals, multi-building campuses, and data centers on gas mains.
250 kW natural gas standby generator with Cummins GTA855E 14L inline-6 engine. PowerCommand 3.3 control, UL 2200 listed, NFPA 110 Type 10 Level 1/2 capable. EPA SI NSPS stationary emergency certified.
2.5 MW diesel with QSK60 V-16 engine at peak output. Full Cummins vertical integration. Maximum QSK60 platform capacity in a single genset.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby for Tier III/IV data centers, large industrial plants, and mission-critical infrastructure requiring maximum QSK60 output.
2500 kW diesel standby generator with QSK60 60L V-16 engine. PowerCommand control, liquid-cooled, top of the QSK60 platform for data center and mission-critical standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C275 D6
275 kW diesel with Cummins QSL9-G7 engine and HPCR fuel system. Available in Tier 3 (DQDAB) and Tier 4 (C275D6D) configurations. Single-source warranty.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for hospitals, data centers, and large commercial buildings requiring high-capacity emergency power.
275 kW EPA Tier 3 diesel standby generator with Cummins QSL9-G7 inline-6 engine and PowerCommand 2.3 control. HPCR fuel system, sound-attenuated enclosure, for commercial and industrial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C2750 D6e
2.75 MW Centum Series with QSK78-G36 engine (launched 2024). Smaller footprint than traditional mega-diesels. PowerCommand 3.3 for hyperscale arrays.
2.8 MW standby · Diesel · Liquid-cooled
2750 kW Centum diesel standby for hyperscale data centers and mission-critical facilities requiring near-3 MW premium standby power.
2750 kW Centum Series diesel standby generator with QSK78-G36 engine, launched 2024. PowerCommand 3.3 controller, charged air-cooled intake, single-source Cummins integration for hyperscale data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C300 D6
300 kW diesel with Cummins QSL9-G7 engine. Top of the QSL9 standby range. PowerCommand 2.3 control with AmpSentry protection. Single-source warranty.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, data centers, and large commercial facilities requiring the maximum QSL9 standby output.
300 kW EPA Tier 3 diesel standby generator with Cummins QSL9-G7 inline-6 engine and PowerCommand 2.3 control. HPCR fuel system, sound-attenuated enclosure, for large commercial and industrial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C300 N6
300 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Paralleling-ready controller.
300 kW standby · Natural Gas · Liquid-cooled
300 kW natural gas standby for hospitals, university campuses, and large commercial on gas mains.
300 kW natural gas standby generator with GTA 855E engine. 300 kW / 375 kVA standby, PowerCommand 3.3 controls, 4098 CFH full-load, open set dimensions 147 x 69 x 77 in. UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C3000 D6
3 MW diesel with QSK95-G2 V-16 engine. Cummins' largest displacement platform. Full vertical integration. Paralleling for 6-30 MW arrays.
3 MW standby · Diesel · Liquid-cooled
3000 kW diesel standby for hyperscale data centers, large industrial complexes, and utility-scale mission-critical infrastructure.
3000 kW diesel standby generator with QSK95-G2 95L V-16 engine. PowerCommand control, liquid-cooled, for data center, utility, and mission-critical standby applications requiring 3 MW single-engine power.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C3000 D6eb
3 MW Centum Series flagship with QSK78-G37 engine. Smaller footprint than QSK95-based alternatives. PowerCommand 3.3, charged air-cooled intake.
3 MW standby · Diesel · Liquid-cooled
3000 kW Centum diesel standby for hyperscale data centers and mission-critical facilities requiring 3 MW premium standby power in a compact platform.
3000 kW Centum Series diesel standby generator with QSK78-G37 engine. PowerCommand 3.3 controller, charged air-cooled intake, single-source Cummins integration, the flagship Centum genset for hyperscale data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C3250 D6
3.25 MW diesel with QSK95-G2 V-16. Mid-range of the QSK95 platform. Full Cummins vertical integration for hyperscale standby arrays.
3.3 MW standby · Diesel · Liquid-cooled
3250 kW diesel standby for hyperscale data centers, large industrial complexes, and mission-critical infrastructure.
3250 kW diesel standby generator with QSK95-G2 95L V-16 engine. PowerCommand control, liquid-cooled, for hyperscale data center and mission-critical standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C35 D6
35 kW diesel with Cummins 4BT3.3 engine. Same proven block as the C25-C60 range. Sound-attenuated enclosure standard.
35 kW standby · Diesel · Liquid-cooled
35 kW diesel standby for small retail, branch offices, and light-industrial facilities requiring reliable emergency power.
35 kW EPA Tier 3 diesel standby generator with Cummins 4BT3.3-G5 engine and PowerCommand 1.1 control. Sound-attenuated enclosure, liquid-cooled, for small commercial and light-industrial standby.
Tier 33-phasecommercial-standbysmall-office
Cummins
Cummins C350 D6
350 kW diesel with full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT at comparable kW.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for large hospitals, industrial plants, and data centers with critical loads.
350 kW diesel standby generator with QSG12-G1 inline-6 engine and HPCR fuel system. EPA Tier 3 compliant, PowerCommand control, liquid-cooled, for large commercial and industrial standby applications.
Tier 33-phasecommercial-standbylarge-commercial
Cummins
Cummins C3500 D6
3.5 MW diesel with QSK95-G2 V-16 at peak output. Cummins' largest single-engine D6 genset. Full vertical integration for hyperscale standby arrays.
3.5 MW standby · Diesel · Liquid-cooled
3500 kW diesel standby for hyperscale data centers, utility-scale standby, and the largest single-engine mission-critical applications.
3500 kW diesel standby generator with QSK95-G2 95L V-16 engine. PowerCommand control, liquid-cooled, the largest D6 Commercial Diesel genset for hyperscale data center and utility standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C40 D6
40 kW diesel with Cummins 4BT3.3 engine. Top of the small B-series range. Sound-attenuated enclosure and PowerCommand control standard.
40 kW standby · Diesel · Liquid-cooled
40 kW diesel standby for small commercial buildings, restaurants, and light-industrial facilities needing mid-range backup power.
40 kW EPA Tier 3 diesel standby generator with Cummins 4BT3.3-G5 engine and PowerCommand 1.1 control. Sound-attenuated enclosure, liquid-cooled, for small commercial and light-industrial standby.
Tier 33-phasecommercial-standbysmall-office
Cummins
Cummins C400 D6
400 kW diesel with full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT at comparable kW.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for large hospitals, industrial plants, and data centers with critical loads.
400 kW diesel standby generator with QSG12-G4 inline-6 engine and HPCR fuel system. EPA Tier 3 compliant, PowerCommand control, liquid-cooled, for large commercial and industrial standby applications.
Tier 33-phasecommercial-standbylarge-commercial
Cummins
Cummins C400 N6
400 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Paralleling for multi-MW gas.
400 kW standby · Natural Gas · Liquid-cooled
400 kW natural gas standby for major hospitals, large campuses, and Tier II data centers on gas.
400 kW natural gas standby generator with Cummins GTA28E 28L inline-6 engine. PowerCommand 3.3 control, UL 2200 listed, EPA SI NSPS certified, NFPA 110 Type 10 Level 1/2 capable. Dimensions 4216 x 2083 x 2486 mm.
450 kW diesel with QSX15 DOHC engine. 30% fewer parts than comparable platforms. Full Cummins vertical integration.
450 kW standby · Diesel · Liquid-cooled
450 kW diesel standby for large hospitals, industrial plants, and data centers requiring high reliability.
450 kW diesel standby generator with QSX15 inline-6 DOHC engine. EPA NSPS certified, PowerCommand control, liquid-cooled, for large commercial and industrial standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C500 D6
500 kW diesel with QSX15 DOHC engine. 30% fewer parts than comparable platforms. Full Cummins vertical integration.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for Tier III data centers, major hospitals, and large industrial facilities.
500 kW diesel standby generator with QSX15 inline-6 DOHC engine. EPA NSPS certified, PowerCommand control, liquid-cooled, for large commercial, industrial, and data center standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C500 N6
500 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel infrastructure needed.
500 kW standby · Natural Gas · Liquid-cooled
500 kW natural gas standby for data centers, large hospitals, and campus microgrids on gas mains.
500 kW natural gas standby generator with GTA 28E V12 engine. 500 kW / 625 kVA standby, PowerCommand 3.3 controls, 6994 CFH full-load, open set dimensions 166 x 82 x 98 in. UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C550 N6
550 kW natural gas standby powered by the GTA28 gas engine. Industrial-grade gas power without diesel logistics.
550 kW standby · Natural Gas / LPG · Liquid-cooled
550 kW natural gas standby for large commercial buildings, hospitals, data centers, and industrial facilities with natural gas service.
550 kW natural gas standby generator with GTA28 gas engine. 550 kW / 688 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C60 D6
60 kW diesel with Cummins 4BT3.3-G7 engine. Bridge between small and mid-size commercial generators. Sound-attenuated enclosure standard.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for mid-size offices, retail centers, and commercial buildings requiring moderate emergency power capacity.
60 kW EPA Tier 3 diesel standby generator with Cummins 4BT3.3-G7 engine and PowerCommand 1.1 control. Sound-attenuated enclosure, liquid-cooled, for commercial and light-industrial standby applications.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C60 N6
60 kW natural gas with full Cummins vertical integration. QuietConnect-class sound levels. No diesel storage needed.
60 kW standby · Natural Gas / LPG · Liquid-cooled
60 kW natural gas standby for restaurants, small offices, and commercial buildings on gas mains.
600 kW diesel with QSK19 engine. Full Cummins vertical integration. MCRS fuel system for lower emissions and fuel consumption.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for large hospitals, data centers, and heavy industrial plants with critical power requirements.
600 kW diesel standby generator with QSK19 19L inline-6 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for large commercial, industrial, and data center standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C600 N6
600 kW natural gas standby powered by the GTA38 gas engine. Industrial-grade gas power without diesel fuel infrastructure.
600 kW standby · Natural Gas / LPG · Liquid-cooled
600 kW natural gas standby for hospitals, data centers, large commercial buildings, and industrial facilities with natural gas service.
600 kW natural gas standby generator with GTA38 gas engine. 600 kW / 750 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C650 N6
650 kW natural gas standby powered by the GTA38 gas engine. Top-end GTA38 output without diesel fuel infrastructure.
650 kW standby · Natural Gas / LPG · Liquid-cooled
650 kW natural gas standby for hospitals, data centers, large commercial buildings, and industrial facilities with natural gas service.
650 kW natural gas standby generator with GTA38 gas engine. 650 kW / 813 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C750 D6
750 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. Paralleling capable.
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
750 kW diesel standby generator with QSK23-G3 23.1L inline-6 engine and HPI-PT fuel injection. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C750 N6
750 kW natural gas with full Cummins vertical integration. GTA50 engine platform. Paralleling for multi-MW gas backup.
750 kW standby · Natural Gas · Liquid-cooled
750 kW natural gas standby for mission-critical data centers and large campus power on gas mains.
750 kW standby natural gas generator with GTA50 engine. PowerCommand 3.3 controls, AmpSentry protection, UL 2200, NFPA 110 Type 10 load acceptance.
3-phasecommercial-standbyindustrial
Cummins
Cummins C80 D6
80 kW diesel with full Cummins vertical integration. 100% load acceptance in 10 seconds. One throat to choke.
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial buildings, healthcare clinics, and municipal water systems.
80 kW EPA Tier 3 diesel standby generator with QSB5-G13 engine and PowerCommand 2.3 control. Sound-attenuated aluminum enclosure, liquid-cooled, rated for 50°C ambient operation.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C80 N6
80 kW natural gas with full Cummins vertical integration. QuietConnect-class sound levels. No fuel storage permits.
80 kW standby · Natural Gas / LPG · Liquid-cooled
80 kW natural gas standby for mid-size commercial, assisted living, and retail with gas service.
80 kW natural gas standby generator with QSJ5.9G engine. PowerCommand 1.1 controls, UL 2200, IBC Seismic, NFPA 110 capable. Quiet Connect RS80 series in sound-attenuated aluminum enclosure.
3-phasecommercial-standbylight-commercial-standby
Cummins
Cummins C800 D6
800 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. Paralleling for multi-MW.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses requiring N+1 redundancy.
800 kW diesel standby generator with QSK23-G3 23.1L inline-6 engine and HPI-PT fuel injection. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C800 N6
800 kW natural gas standby powered by the GTA50 gas engine. High-capacity gas power without diesel fuel infrastructure.
800 kW standby · Natural Gas / LPG · Liquid-cooled
800 kW natural gas standby for hospitals, data centers, large commercial complexes, and industrial facilities with natural gas service.
800 kW natural gas standby generator with GTA50 gas engine. 800 kW / 1000 kVA standby, PowerCommand controls, AmpSentry protection, UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C900 D6
900 kW diesel with QST30 V-12 engine. Full Cummins vertical integration. 100% load in 10 seconds. Paralleling for multi-MW.
900 kW standby · Diesel · Liquid-cooled
900 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure.
900 kW diesel standby generator with QST30-G3 30L V-12 engine. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins KTA38
887 kW diesel with legendary KTA38 engine. Full Cummins vertical integration. Parts availability back decades.
887 kW standby · Diesel · Liquid-cooled
887 kW diesel standby for large industrial plants, hospitals, and mission-critical infrastructure.
887 kW standby / 811 kW prime diesel generator at 50 Hz. KTA38-G5 37.8L V12 PT fuel injection. Legacy Cummins platform for industrial, hospital, campus, and mining standby applications.
3-phaseindustrialhospital-large
Cummins
Cummins KTA50
1340 kW diesel with legendary KTA50 engine. Full Cummins vertical integration. 10-15% below CAT 3512 class.
1.3 MW standby · Diesel · Liquid-cooled
1340 kW diesel standby for Tier III+ data centers, large hospitals, and heavy industrial plants.
1340 kW standby / 1200 kW prime diesel generator at 50 Hz. KTA50-GS8 50.3L V16 PT fuel injection, 2-pump 2-loop cooling. Legacy Cummins platform for data center, industrial, hospital, and mining standby applications.
3-phasedata-centerhospital-large
Cummins
Cummins QSB7 (C200 D6)
200 kW diesel with QSB7 engine. Full Cummins vertical integration. 100% load in 10 seconds. Best cold-weather start (-40F).
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, office complexes, and commercial buildings in any climate.
200 kW diesel commercial standby generator with Cummins QSB7 6.7L engine. The mid-range diesel workhorse for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Cummins
Cummins QSK19
550 kW diesel with QSK19 engine. Full Cummins vertical integration. Power Command controller. 10-15% below CAT.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for large data centers, hospitals, and heavy industrial plants.
550 kW standby / 500 kW prime diesel generator with QSK19-G4 19L inline-6 MCRS engine. EPA Tier 2, CTT HX83 turbocharging, 24V starting. Engine dimensions 1695 x 985 x 1723 mm, dry weight 1900 kg.
Tier 23-phasehospital-mediumcampus
Cummins
Cummins QSK23
800 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
800 kW standby / 727 kW prime diesel generator with QSK23-G3 23.1L inline-6 HPI-PT engine. Non-regulated, CTT HX82 turbocharging, 24V starting. Engine dimensions 2976 x 1656 x 1964 mm, dry weight 3245 kg.
Tier 23-phasehospital-largecampus
Cummins
Cummins QSK38
1160 kW diesel with QSK38 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.
1.2 MW standby · Diesel · Liquid-cooled
1160 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
1160 kW standby / 965 kW prime diesel generator with QSK38-G5 37.7L V12 MCRS engine. EPA Tier 2, 2P2L cooling, 24V starting. Engine dimensions 2081 x 1492 x 1860 mm, dry weight 4100 kg.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK50
1500 kW diesel with QSK50 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3512.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants.
1500 kW standby / 1365 kW prime diesel generator with QSK50-G4 50.3L V16 MCRS engine. EPA Tier 2 and TA Luft compliant, 2P2L cooling, 24V starting. Engine dimensions 4674 x 2468 x 3100 mm, dry weight 7429 kg.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK60
2000 kW diesel with QSK60 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3516.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for hyperscale data centers, large hospitals, and campus microgrids.
2000 kW diesel standby generator. The data center industry standard — V-16, 60.2L, Tier 2. Cummins' flagship for mission-critical power.
Tier 23-phasedata-centerhospital
Cummins
Cummins QSK78
2750 kW diesel with QSK78 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3516B.
2.8 MW standby · Diesel · Liquid-cooled
2750 kW diesel standby for hyperscale data centers, critical infrastructure, and utility peaking.
2750 kW standby / 2500 kW prime diesel generator with QSK78-G14 V18 engine. EPA Tier 4 Final, 78-liter displacement for mission-critical and data center power.
Tier 4 Final3-phasedata-centerhospital
Cummins
Cummins QSK95
3010 kW diesel with QSK95 engine -- Cummins largest. Full vertical integration. Paralleling for campus-scale power.
3.0 MW standby · Diesel · Liquid-cooled
3010 kW diesel standby for hyperscale data centers, campus microgrids, and utility peak shaving.
3010 kW standby / 2690 kW prime diesel generator with QSK95-G10 V16 engine. EPA Tier 2, quad turbo, MCRS fuel injection, ISO 8528-G3 transient capability.
Tier 23-phasedata-centerhospital
Cummins
Cummins QSL9
300 kW diesel with QSL9 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, multi-building campuses, and industrial plants.
300 kW standby / 275 kW prime diesel generator with QSL9-G7 8.8L inline-6 Bosch HPCR engine. EPA Tier 3 / EU Stage IIIA compliant, Holset HX40 wastegated turbo, 24V starting. Engine dimensions 2157 x 1126 x 1562 mm, dry weight 940 kg.
500 kW diesel with QSX15 engine. Full Cummins vertical integration. Power Command controller. 10-15% below CAT.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for major hospitals, Tier III data centers, and large industrial facilities.
500 kW standby / 450 kW prime diesel generator with QSX15-G9 engine. 24-valve DOHC, 15-liter inline-6, EPA NSPS certified for commercial and industrial power.
3-phasecommercial-standbyindustrial
Cummins
Cummins RS100
100 kW liquid-cooled standby with turbocharged 5.9L Cummins engine. Maximum output from the 5.9L platform, 71 dB quiet operation, PowerCommand 1.1.
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW residential standby for ultra-large estates, multi-structure properties, and small commercial facilities on natural gas or propane.
100 kW liquid-cooled residential standby generator. Natural gas or LP, field selectable. 5.9L turbocharged inline 6-cylinder, 1800 rpm, 71 dB(A) at 23 ft, 180 mph wind rated, PowerCommand 1.1 controls.
3-phaseresidentialsmall-commercial
Cummins
Cummins RS125
125 kW liquid-cooled standby with turbocharged 8.9L Cummins engine. 520.8 amps at 120/240V, 71 dB quiet operation, and PowerCommand 2.3 controls.
125 kW standby · Natural Gas / LPG · Liquid-cooled
125 kW residential standby for ultra-large estates, multi-structure properties, and commercial facilities on natural gas or propane.
125 kW liquid-cooled residential standby generator. Natural gas or LP, field selectable. 8.9L turbocharged inline 6-cylinder, 1800 rpm, 71 dB(A) at 23 ft, 180 mph wind rated, PowerCommand 2.3 controls.
3-phaseresidentialsmall-commercial
Cummins
Cummins RS13A
13 kW whole-house backup with air-cooled simplicity. 65 dB quiet operation, automatic transfer, and 5-year warranty coverage.
13 kW standby · Natural Gas / LPG · Air-cooled
13 kW residential standby for small to mid-size homes with essential circuit backup on natural gas or propane.
13 kW air-cooled residential standby generator. Natural gas or LP, field selectable. 65 dB(A) at 23 ft, 180 mph wind rated, 5-year / 2,000-hour warranty. Quiet Connect series.
Single-phaseresidential
Cummins
Cummins RS150
150 kW liquid-cooled standby with turbocharged 8.9L Cummins engine. 625 amps at 120/240V, 71 dB quiet operation, and PowerCommand 2.3 controls.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW residential standby for ultra-large estates, multi-structure properties, and commercial facilities on natural gas or propane.
150 kW liquid-cooled residential standby generator. Natural gas or LP, field selectable. 8.9L turbocharged inline 6-cylinder, 1800 rpm, 71.3 dB(A) at 23 ft, 180 mph wind rated, PowerCommand 2.3 controls.
3-phaseresidentialsmall-commercial
Cummins
Cummins RS17A
17 kW whole-house backup with air-cooled simplicity. 65 dB quiet operation, 34 kVA motor starting, and 5-year warranty coverage.
17 kW standby · Natural Gas / LPG · Air-cooled
17 kW residential standby for mid-size homes needing whole-house backup including central A/C on natural gas or propane.
17 kW air-cooled residential standby generator. Natural gas or LP, field selectable. 65 dB(A) at 23 ft, 180 mph wind rated, 5-year / 2,000-hour warranty. Quiet Connect series.
Single-phaseresidential
Cummins
Cummins RS20A
20 kW whole-house backup with air-cooled simplicity. 65 dB quiet operation, starts a 5-ton A/C under full pre-load, 5-year warranty.
20 kW standby · Natural Gas / LPG · Air-cooled
20 kW residential standby for mid to large homes needing whole-house backup including 5-ton central A/C on natural gas or propane.
20 kW air-cooled residential standby generator. Natural gas or LP, field selectable. 65 dB(A) at 23 ft, 180 mph wind rated, 5-year / 2,000-hour warranty. Starts a 5-ton A/C.
Single-phaseresidential
Cummins
Cummins RS50
50 kW liquid-cooled standby with Cummins 5.9L inline-6 engine. Quiet 72 dB operation, automatic transfer, and PowerCommand 1.1 controls.
50 kW standby · Natural Gas / LPG · Liquid-cooled
50 kW residential standby for estate homes and large properties needing high-capacity whole-house backup on natural gas or propane.
50 kW liquid-cooled residential standby generator. Natural gas or LP, field selectable. 5.9L inline 6-cylinder, 1800 rpm, 72 dB(A) at 23 ft, 180 mph wind rated, PowerCommand 1.1 controls.
3-phaseresidentialsmall-commercial
Cummins
Cummins RS60
60 kW liquid-cooled standby with Cummins 5.9L inline-6 engine. 250 amps at 120/240V, 69.8 dB quiet operation, and PowerCommand 1.1 controls.
60 kW standby · Natural Gas / LPG · Liquid-cooled
60 kW residential standby for large estate homes and luxury residences needing high-capacity whole-house backup on natural gas or propane.
60 kW liquid-cooled residential standby generator. Natural gas or LP, field selectable. 5.9L inline 6-cylinder, 1800 rpm, 69.8 dB(A) at 23 ft, 180 mph wind rated, PowerCommand 1.1 controls.
3-phaseresidentialsmall-commercial
Cummins
Cummins RS80
80 kW liquid-cooled standby with turbocharged 5.9L Cummins engine. 333 amps at 120/240V, 70.5 dB quiet operation, and PowerCommand 1.1 controls.
80 kW standby · Natural Gas / LPG · Liquid-cooled
80 kW residential standby for large estate homes, luxury properties, and small commercial facilities needing high-capacity backup on natural gas or propane.
80 kW liquid-cooled residential standby generator. Natural gas or LP, field selectable. 5.9L turbocharged inline 6-cylinder, 1800 rpm, 70.5 dB(A) at 23 ft, 180 mph wind rated, PowerCommand 1.1 controls.