The Kohler 500REZK — a 500 kW Siemens-powered natural gas generator for large commercial and industrial standby.

500500 kW1 modelnatural gas

Series Overview#

The Kohler Industrial Gaseous category at 500 kW is represented by a single model: the 500REZK. Unlike the rest of Kohler's gaseous industrial lineup — which uses Doosan, PSI/Doosan, or Kohler-branded engines — the 500REZK is powered by a Siemens SGE-24SL natural gas engine. This makes it a distinct product from the REZX Series that covers 180–500 kW in LPG and dual-fuel configurations. The 500REZK is natural-gas-only, operating at 1800 RPM with a Brushless Permanent-Magnet Pilot Exciter alternator.

At 490–500 kW standby and 430–435 kW prime, the 500REZK occupies the upper boundary of what is achievable as a single-unit gaseous genset in the North American market. It is EPA certified for both stationary emergency and non-emergency operation, giving facility operators the flexibility to use the unit for demand response, peak shaving, or prime power applications in addition to emergency standby duty. This dual-certification distinguishes it from most standby-only competitors at this power level.

The unit supports three-phase output in 208V, 240V, and 480V configurations. It is a liquid-cooled platform, consistent with the industrial gaseous series, and is designed for commercial and industrial facilities where natural gas service is available and on-site diesel storage is not desired or permitted.

How to Choose#

The 500REZK is a single-model series — there is no sizing decision to make within this product line. The decision is whether the 500REZK is the right unit for your application:

Choose the 500REZK if: Your facility requires approximately 500 kW of natural-gas-only standby power. You have confirmed that your gas utility can deliver adequate pressure and volume to sustain the engine under full load. You need dual emergency/non-emergency certification for operational flexibility or regulatory reasons. You are comparing this unit against the 500REZXD (LPG-rated PSI/Doosan) — the 500REZK is the natural gas option at this power level.

Consider alternatives if: Your load requirement is significantly above or below 500 kW, in which case the REZX Series (180–500 kW range) or the KD Series diesel platform (900–4000 kW) may be more appropriate. If LPG is an acceptable fuel, the 500REZXD provides the same rated output with a different engine platform. If your facility requires medium-voltage output, neither the 500REZK nor the REZX Series supports that natively — the large REOZ diesel series is the correct choice.

Common Applications#

Service & Maintenance#

The 500REZK uses a 500-hour or 12-month oil change interval — longer than the 250-hour interval typical of the smaller REZXB models, reflecting the Siemens engine's specification. Coolant is replaced at 4,000 hours, air filter at 1,000 hours, and spark plugs at 1,000 hours. The 1,000-hour spark plug interval is longer than the 500-hour interval seen on the Doosan-powered REZX models, but spark plug condition should still be inspected at every annual service regardless of hour count.

The most maintenance-sensitive components in this unit are the spark plug and ignition system (typical symptom onset around 1,000 hours: misfire, cylinder dropout, rough running under load) and the gas train/pressure regulator (hard starting, gas pressure fault, no-start condition at approximately 8,000 hours). The turbocharger seals are the primary wear component between 10,000 and 12,000 hours — oil carryover, blue smoke, and boost pressure loss are typical early indicators.

Starting battery condition should be checked at every service interval. A battery that appears functional under float charge may fail to deliver adequate cranking amperage after the unit has been dormant between outages. Replace batteries on a two-to-three-year cycle regardless of apparent state of health.

All Industrial Gaseous Models

ModelStandby kWPrime kWVoltageEngineEmissionsFuel
Kohler 500REZK500435208V, 240V, 480VSiemens SGE-24SLnatural gas

Frequently Asked Questions

What engine does the Kohler 500REZK use?
The 500REZK is powered by a Siemens SGE-24SL natural gas engine — an unusual choice for Kohler, which typically sources its gaseous engines from Kohler or Doosan/PSI. The Siemens engine platform provides the power density required to reach 500 kW from a natural gas genset.
Is the 500REZK certified for prime power operation?
Yes. The 500REZK carries EPA certification for both stationary emergency and non-emergency operation. At 430–435 kW prime rating, it is suitable for continuous-duty and prime power applications as well as standby.
What voltage configurations are available?
The 500REZK is available in 208V, 240V, and 480V three-phase configurations. Single-phase output is not available. Confirm voltage requirements before ordering.
What are the service intervals?
The 500REZK follows a 500-hour or 12-month oil change interval, coolant at 4,000 hours, air filter at 1,000 hours, and spark plugs at 1,000 hours. Spark plug service is longer than the typical 500-hour interval seen on smaller REZX models, reflecting the Siemens engine's different specification.
How does the 500REZK fit relative to the REZXD line?
The 500REZXD (also 500 kW, LPG) is the nearest equivalent in the REZX Series. The 500REZK is natural-gas-only and uses the Siemens SGE-24SL engine rather than the PSI/Doosan D219L. If natural gas is the required fuel and your utility service can support the gas demand, the 500REZK is the appropriate model.