100 to 500 kW is the commercial standby sweet spot — covering most multi-tenant office buildings, mid-size data centers, hospitals, and retail anchors. Both diesel and gaseous gensets are well-represented in this band. EPA Tier 4 Final compliance starts at 56 kW, so most diesel units in this band require DPF and SCR aftertreatment; gaseous units fall under EPA Stationary Spark Ignition rules and avoid liquid-aftertreatment maintenance.
241 models in this category.
Need help selecting a generators 100–500 kw?
Our application engineers help size, spec, and source backup power for commercial, industrial, and mission-critical sites.
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
110 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
125 kVA hybrid energy system with 65 kWh LTO battery storage. Diesel-battery hybrid for reduced fuel and emissions.
3-phaseconstructionrental-fleet
Airman
Airman EBOSS 220-125
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
194 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
220 kVA hybrid energy system with 125 kWh LTO battery storage. Diesel-battery hybrid for large sites.
3-phaseconstructionrental-fleet
Airman
Airman EBOSS 400-220
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
336 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
400 kVA hybrid energy system with 220 kWh LTO battery storage. Flagship diesel-battery hybrid.
3-phaseconstructionrental-fleet
Airman
Airman SDG125
0.001% warranty claim rate, 110% fluid containment standard, 23.3-hr runtime at 100 kW — premium Isuzu-powered reliability for serious commercial and emergency standby applications.
110 kW standby · Diesel · Liquid-cooled
Full-size 100 kW portable for large commercial construction, emergency standby, data center temporary power, and infrastructure projects requiring overnight unattended operation.
100 kW prime diesel portable generator. Isuzu BR-4HK1X engine with 23.3-hour runtime, 110% fluid containment, and switchable output.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG150
0.001% warranty claim rate, 110% fluid containment standard, 66 dBA at 7m, 24-hr runtime at 120 kW — John Deere 6068 reliability with Hokuetsu precision engineering.
132 kW standby · Diesel · Liquid-cooled
Full-size 120 kW portable for large commercial construction, emergency standby, and noise-sensitive urban applications where the 66 dBA rating and environmental compliance are required.
120 kW prime diesel portable generator. John Deere 6068-powered with 24-hour runtime, 66 dBA operation, and 110% fluid containment.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG220S
Industry-leading 0.001% warranty claim rate with 110% fluid containment standard — no separate secondary containment needed on CA sites.
194 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites requiring ultra-reliability and environmental compliance.
220 kVA (176 kW prime) portable diesel generator with 110% fluid containment and John Deere engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 125
±0.25% voltage regulation, 500-hr service intervals, 166-gal tank for extended runtime at 100 kW prime
110 kW standby · Diesel · Liquid-cooled
Large construction sites, emergency temporary power, and rental fleet deployment needing 100 kW portable output
100 kW prime diesel portable generator. John Deere 4045-powered with 73 dBA operation, Leroy Somer alternator, and 166-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 150
70 dBA — quieter than its 100 kW sibling, 335-gal tank for 43+ hr runtime, dual 50/60 Hz capability
132 kW standby · Diesel · Liquid-cooled
Large construction, infrastructure projects, and extended-runtime temporary power needing 120 kW with minimal refueling
120 kW prime diesel portable generator. John Deere 6068-powered with 70 dBA operation, 335-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 175
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
154 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
175 kVA (140 kW prime) portable diesel generator. Swedish-engineered QAS series with FPT engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 200
71 dBA — quiet for 160 kW class, shared 6068 platform with QAS 150 for fleet parts commonality, 36+ hr runtime
176 kW standby · Diesel · Liquid-cooled
Large construction, infrastructure, and rental fleet operations needing 160 kW portable power with platform commonality
160 kW prime diesel portable generator. John Deere 6068-powered with 71 dBA operation, 335-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 235
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
206 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
234 kVA (187 kW prime) portable diesel generator. Swedish-engineered QAS series with FPT engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 250
73 dBA — competitive for 200 kW class, 385-gal tank for 34+ hr runtime, 800A breaker, shared platform with QAS 330
220 kW standby · Diesel · Liquid-cooled
Heavy construction, utility temporary power, and data center backup needing 200 kW portable output with extended runtime
200 kW prime diesel portable generator. John Deere-powered with 73 dBA operation, 385-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 330
73 dBA — same noise as QAS 250 with 32% more power, shared 9.0L platform for fleet parts commonality, 25+ hr runtime
290 kW standby · Diesel · Liquid-cooled
Heavy construction, data center temporary power, and large commercial operations needing 250+ kW portable output
264 kW prime diesel portable generator. John Deere-powered with 73 dBA operation, 385-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 410
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
361 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
410 kVA (328 kW prime) portable diesel generator. Swedish-engineered QAS series with Scania engine.
Tier 4 Final3-phaseconstructionrental-fleet
Blue Star Power Systems
Blue Star GM100-03
Open Basler controller + PSI engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby for commercial, school, and multi-family buildings where gas-fueled backup and component independence matter.
100 kW natural gas standby generator (80 kW on LP) from Blue Star Power Systems. PSI 5.7LTCAC turbocharged charge-air-cooled V8, Stamford UCI274C alternator, DSE DCP7310 controller, 208-600V output.
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, multi-family, and municipal facilities where value engineering and service-tech independence matter.
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine with charge air cooling, Stamford UCI274 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD150-01
Open Basler controller + John Deere 6068 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and component independence matter.
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HF285 6-cylinder engine, Stamford UCI274/UCDI274 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD200-01
Open Basler controller + John Deere 6068 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for value-engineering projects, municipal facilities, and service-savvy buyers who prioritize component independence.
200 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HFG85 6-cylinder engine, Stamford S4L1S/UCDI274 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD250-02
Open Basler controller + John Deere 6090 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for commercial, institutional, and campus facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HF484 9.0L 6-cylinder engine, Stamford S4L1S/S4L1D alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD275-02
Open Basler controller + John Deere 6090 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
275 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HF484 9.0L 6-cylinder engine, Stamford S4L1S alternator, DSE DCP7310 controller. Three-phase only.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD300-02
Open Basler controller + John Deere 6090 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for large commercial, campus, and municipal facilities where value engineering and non-proprietary component access matter.
300 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HFG86 9.0L 6-cylinder engine, Stamford S4L1D alternator, DSE DCP7310 controller. Three-phase only.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star NG150-01
Open Basler controller + PSI engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas standby for commercial, institutional, and campus buildings where gas-fueled backup and component independence matter.
150 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.1LT turbocharged inline-six, DSE DCP7310 controller, 208-600V output.
Open Basler controller + PSI engine + Stamford alternator — prime-rated, no proprietary lock-in. Serviceable by any qualified tech.
150 kW standby · Natural Gas / LPG · Liquid-cooled
125 kW prime natural gas for continuous-duty commercial and institutional applications needing 24/7 gas-fueled power with component independence.
125 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 8.1LT inline-six, DSE DCP7310 controller, 208-600V, continuous prime duty.
Open Basler controller + PSI engine + Stamford alternator — prime-rated, no proprietary lock-in. Serviceable by any qualified tech.
200 kW standby · Natural Gas / LPG · Liquid-cooled
175 kW prime natural gas for continuous-duty commercial and institutional applications needing 24/7 gas-fueled power with component independence.
175 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 11.1L inline-six, DSE DCP7310 controller, 208-600V, continuous prime duty.
Open Basler controller + PSI engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
265 kW standby · Natural Gas / LPG · Liquid-cooled
265 kW natural gas standby for large commercial, campus, and hospital (non-critical) facilities where gas-fueled backup matters.
265 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 14.6L turbocharged V8, DSE DCP7310 controller, structural steel base, 208-600V.
Open Basler controller + PSI engine + Stamford alternator — prime-rated, no proprietary lock-in. Serviceable by any qualified tech.
265 kW standby · Natural Gas / LPG · Liquid-cooled
250 kW prime natural gas for continuous-duty commercial, CHP, and campus applications needing 24/7 gas-fueled power.
250 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 14.6L V8, DSE DCP7310 controller, structural steel base, continuous prime duty.
Open Basler controller + PSI engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
300 kW standby · Natural Gas / LPG · Liquid-cooled
300 kW natural gas standby for large commercial, campus, and institutional facilities where gas-fueled backup and component independence matter.
300 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 14.6L turbocharged V8, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
Open Basler controller + PSI engine + Stamford alternator — prime-rated, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Natural Gas / LPG · Liquid-cooled
260 kW prime natural gas for continuous-duty commercial, CHP, and campus applications needing 24/7 gas-fueled power.
260 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 14.6L V8, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
Open Basler controller + PSI high-output engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech.
350 kW standby · Natural Gas · Liquid-cooled
350 kW natural gas standby for large commercial, campus, and data center facilities where gas-fueled backup and component independence matter.
350 kW natural gas standby generator from Blue Star Power Systems. PSI 14.6LHO high-output V8, DSE DCP7310 controller, structural steel base, three-phase 208-600V. Natural gas only — no LP rating.
Open Basler controller + PSI V12 engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
400 kW standby · Natural Gas / LPG · Liquid-cooled
400 kW natural gas standby for large commercial, campus, and data center facilities where gas-fueled backup and component independence matter.
400 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 21.9L turbocharged V12, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
Open Basler controller + PSI V12 engine + Stamford alternator — prime-rated, no proprietary lock-in. Serviceable by any qualified tech.
400 kW standby · Natural Gas / LPG · Liquid-cooled
375 kW prime natural gas for continuous-duty commercial, CHP, and campus applications needing 24/7 gas-fueled power.
375 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 21.9L V12, DSE DCP7310 controller, structural steel base, three-phase 208-600V.
Open Basler controller + PSI V12 engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
425 kW standby · Natural Gas / LPG · Liquid-cooled
425 kW natural gas standby for large commercial, campus, and data center facilities where gas-fueled backup and component independence matter.
425 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 21.9L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
Open Basler controller + PSI V12 engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
450 kW standby · Natural Gas / LPG · Liquid-cooled
450 kW natural gas standby for large commercial, campus, and data center facilities where gas-fueled backup and component independence matter.
450 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 21.9L V12 turbocharged-aftercooled, DSE DCP7310 controller, three-phase 208-600V.
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, institutional, and municipal facilities where Perkins parts access and non-proprietary components matter.
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, Stamford UCI274C alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD125-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
125 kW standby · Diesel · Liquid-cooled
125 kW diesel standby for commercial, institutional, and municipal facilities where Perkins parts access and component independence matter.
125 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274E alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD150-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and Perkins global parts access matter.
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274F alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD180-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
180 kW standby · Diesel · Liquid-cooled
180 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and Perkins global parts access matter.
180 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG4 six-cylinder engine with charge air cooling, Stamford UCI274G alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD200-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for value-engineering projects, municipal facilities, and service-savvy buyers who prioritize component independence.
200 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG5 six-cylinder engine with charge air cooling, Stamford UCI274H alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD250-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1706D-E93TAG1 six-cylinder engine with charge air cooling, Stamford S4L1D-C41 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD300-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
300 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1706D-E93TAG2 six-cylinder engine with charge air cooling, Stamford S4L1D-D41 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star PD350-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for large commercial, industrial, and campus facilities where Perkins parts access and component independence matter.
350 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2206D-E13TAG2 six-cylinder engine with charge air cooling, Stamford S4L1D-E41 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star PD400-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for industrial, campus, and data center facilities where value engineering and non-proprietary component access matter.
400 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2206D-E13TAG3 six-cylinder engine with charge air cooling, Stamford S4L1D-F41 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star PD450-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
450 kW standby · Diesel · Liquid-cooled
450 kW diesel standby for industrial, campus, and data center facilities where value engineering and open-architecture components matter.
450 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2506D-E15TAG1 six-cylinder engine with charge air cooling, Stamford HCI534C alternator, DSE DCP7310 controller.
Tier 33-phasecommercialindustrial
Blue Star Power Systems
Blue Star PS130-01
Open Basler controller + PSI engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
130 kW standby · Natural Gas / LPG · Liquid-cooled
130 kW natural gas standby for commercial, school, and multi-family buildings where gas-fueled backup and component independence matter.
130 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.8LTCAC turbocharged V8, DSE DCP7310 controller, 208-600V output.
Open Basler controller + PSI engine + Stamford alternator — no proprietary lock-in. Non-proprietary components serviceable by any qualified tech.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas standby for commercial, school, and institutional buildings where gas-fueled backup and component independence matter.
150 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.8LTCAC turbocharged-aftercooled V8, DSE DCP7310 controller, single- and three-phase 120-600V.
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
100 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD581VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star VD100-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final mobile diesel for construction, emergency response, and temporary power where portability and clean emissions matter.
100 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD581VE four-cylinder engine, Stamford UCI274D alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD125-02FT4
Open Basler DGC-2020 controller + Volvo Penta engine + Stamford alternator — Tier 4 Final, no proprietary lock-in. Serviceable by any qualified tech.
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
125 kW Tier 4 Final diesel standby generator from Blue Star Power Systems. Volvo Penta TAD572VE engine with charge-air cooling, paired with Basler DGC-2020 controller.
Tier 4 Final3-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star VD125-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
125 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD582VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star VD125-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final mobile diesel for construction, emergency response, and temporary power where portability and clean emissions matter.
125 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD582VE four-cylinder engine, Stamford UCI274E alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD150-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel standby for commercial, institutional, and municipal facilities requiring current emissions and component independence.
150 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD881VE 7.7L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD150-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final mobile diesel for construction, planned outage support, and temporary power requiring portability and clean emissions.
150 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD881VE six-cylinder engine, Stamford UCI274F alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD200-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel standby for commercial, institutional, and campus facilities requiring current emissions and component independence.
200 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1180VE 10.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD200-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final mobile diesel for construction, planned outage support, and temporary power requiring portability and clean emissions.
200 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1180VE six-cylinder engine, Stamford UCDI274J1 alternator, DSE DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD230-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
230 kW standby · Diesel · Liquid-cooled
230 kW diesel standby for commercial, institutional, and campus facilities where value engineering and non-proprietary component access matter.
230 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD851GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-03
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for large commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD852GE 7.7L inline-six, DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel standby for commercial, campus, and institutional facilities requiring current emissions and component independence.
250 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1381VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final mobile diesel for construction, planned outage support, and large-scale temporary power with clean emissions.
250 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1381VE six-cylinder engine, Stamford S4L1D-D41 alternator, DSE DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD275-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for large commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
275 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD853GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD300-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
300 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1351GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD300-02FT4
Open Basler DGC-2020 controller + Volvo Penta engine + Stamford alternator — Tier 4 Final, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel standby for large commercial and campus facilities requiring current emissions compliance and open-architecture components.
300 kW Tier 4 Final diesel standby generator. Volvo Penta TAD1373VE 12.8L inline-six, 208-600V output, with Basler DGC-2020 controller and SCR aftertreatment.
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel standby for large commercial, campus, and industrial facilities requiring current emissions and component independence.
300 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1383VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final mobile diesel for construction, planned outage support, and large-scale temporary power with clean emissions.
300 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1383VE six-cylinder engine, Stamford S4L1D-E41 alternator, DSE DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD350-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for large commercial, industrial, and campus facilities where value engineering and non-proprietary component access matter.
350 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1352GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD400-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for industrial, campus, and data center facilities where value engineering and non-proprietary component access matter.
400 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1353GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD450-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
450 kW standby · Diesel · Liquid-cooled
450 kW diesel standby for industrial, campus, and data center facilities where value engineering and non-proprietary component access matter.
450 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1650GE 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Caterpillar
Cat DG400
400 kW natural gas with CAT CG18 engine. EPA certified emergency and non-emergency. No diesel infrastructure needed.
400 kW standby · Natural Gas · Liquid-cooled
400 kW natural gas standby/DR for large commercial, hospitals, and campus facilities on gas mains.
400 kW natural gas generator with Cat CG18 inline-6 engine. Emergency standby, demand response, and limited time power for commercial applications.
3-phasecommercial-standbydemand-response
Caterpillar
Caterpillar C13
350 kW diesel with CAT C13 ACERT inline-6. Best resale -- retains 15-25% more than competitors. ~200 US dealers.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for hospitals, large commercial, and industrial with CAT fleet standardization.
The Caterpillar C13 ACERT is a 350 kW standby diesel generator with EPA Tier 3 certification. 12.5L inline-6 with MEUI injection. Fuel consumption 24.9 gal/hr at full load. Complete specs and service reference.
Tier 33-phasecommercial-standbyhospital-medium
Caterpillar
Caterpillar C7
200 kW diesel with CAT C7 ACERT inline-6. Best resale value in class. ~200 US dealers. Compact footprint.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for retail, telecom, and small commercial with CAT fleet standardization.
The Caterpillar C7.1 ACERT is a 200 kW standby diesel generator with EPA Tier 3 certification. 7.01L inline-6 with MEUI fuel injection. Compact standby power for small commercial and retail applications.
Tier 33-phasecommercial-standbyretail
Caterpillar
Caterpillar C9
250 kW diesel with CAT C9 ACERT inline-6. Best resale -- retains 15-25% more than competitors. ~200 US dealers.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for mid-size commercial, schools, and light-industrial with CAT fleet.
The Caterpillar C9 ACERT is a 250 kW standby diesel generator with EPA Tier 3 emissions certification. 8.8L inline-6 with MEUI fuel injection. Ideal for retail, telecom, and light-industrial standby applications.
Tier 33-phasecommercial-standbyretail
Caterpillar
Caterpillar G3406
300 kW natural gas with CAT G3406 inline-6. No diesel storage needed. Legacy platform with deep parts availability.
300 kW standby · Natural Gas · Liquid-cooled
300 kW natural gas standby for hospitals, commercial campuses, and facilities on gas mains.
The Caterpillar G3406 is a natural gas standby generator built on the 14.6L G3406 TA inline-6 spark-ignited engine. No diesel fuel storage required. Legacy platform for hospitals, campuses, and commercial facilities.
175 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. No diesel infrastructure.
175 kW standby · Natural Gas · Liquid-cooled
175 kW natural gas standby for schools, mid-size hotels, and commercial campuses on gas mains.
175 kW natural gas standby generator with GTA 8.3G engine. 175 kW / 219 kVA standby, PowerCommand 1.1 controls, 2202 CFH full-load, dimensions 115 x 40 x 59 in. ISO 9001:2015 manufactured.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins C200 N6
200 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Power Command controller.
200 kW standby · Natural Gas / LPG · Liquid-cooled
200 kW natural gas standby for large commercial, healthcare, and office towers on gas mains.
200 kW natural gas/propane commercial standby generator. Cummins' flagship gaseous unit with QSJ8.9G engine and PowerCommand 2.3 controller.
300 kW natural gas with full Cummins vertical integration. 100% load in 10 seconds. Paralleling-ready controller.
300 kW standby · Natural Gas · Liquid-cooled
300 kW natural gas standby for hospitals, university campuses, and large commercial on gas mains.
300 kW natural gas standby generator with GTA 855E engine. 300 kW / 375 kVA standby, PowerCommand 3.3 controls, 4098 CFH full-load, open set dimensions 147 x 69 x 77 in. UL 2200, EPA certified.
3-phasecommercial-standbyindustrial-standby
Cummins
Cummins QSB7 (C200 D6)
200 kW diesel with QSB7 engine. Full Cummins vertical integration. 100% load in 10 seconds. Best cold-weather start (-40F).
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, office complexes, and commercial buildings in any climate.
200 kW diesel commercial standby generator with Cummins QSB7 6.7L engine. The mid-range diesel workhorse for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Cummins
Cummins QSL9
300 kW diesel with QSL9 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, multi-building campuses, and industrial plants.
300 kW standby / 275 kW prime diesel generator with QSL9-G7 8.8L inline-6 Bosch HPCR engine. EPA Tier 3 / EU Stage IIIA compliant, Holset HX40 wastegated turbo, 24V starting. Engine dimensions 2157 x 1126 x 1562 mm, dry weight 940 kg.
Cummins QSB5 with no DPF required for Tier 4 Final — simpler maintenance than DPF-equipped competitors. 24.9-hour full-load runtime from 176.5-gallon tank.
110 kW standby · Diesel · Liquid-cooled
Commercial construction, mid-size building emergency standby, rental fleet 125 kVA class, and temporary power for large events or commercial renovations.
100 kW prime diesel portable generator. Cummins QSB5-G11-powered with 68 dBA operation, 176.5-gallon tank, and 24.9-hour runtime.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G150
23% more power than the G125 in the exact same chassis and footprint. Cummins QSB5 with no DPF — bridges the gap before stepping up to the larger DualBox G190.
135 kW standby · Diesel · Liquid-cooled
Commercial construction needing 100-150 kW, rental fleet gap-filler between 125 and 190 kVA classes, and temporary power for mid-size commercial buildings.
123 kW prime diesel portable generator. Cummins QSB5-G12-powered with 68 dBA operation and shared G125 chassis.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G190
First DualBox enclosure model — separated powertrain and cooling compartments for improved thermal management. 368-gallon tank delivers 31.7-hour runtime at Cummins pricing advantage.
160 kW standby · Diesel · Liquid-cooled
Large commercial construction, data center temporary power, utility emergency standby, and rental fleet heavy-duty class.
145 kW prime diesel portable generator. Cummins QSB7-G8-powered with 69 dBA operation, DualBox enclosure, and 368-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G240
Higher-output QSB7 variant in the same DualBox chassis as the G190 — 30% more power without a larger footprint. 27-hour runtime from 368-gallon tank at full load.
200 kW standby · Diesel · Liquid-cooled
Large commercial construction, hospital and data center temporary power, utility emergency standby, and rental fleet heavy-duty class.
190 kW prime diesel portable generator. Cummins QSB7-G9-powered with 69 dBA operation, 368-gallon tank, and 27-hour runtime.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G325
Cummins QSL9 8.9L in the large-frame class at 15-30% below Atlas Copco and MQ Power. 480-gallon tank and 1,000A main breaker for sustained heavy loads.
290 kW standby · Diesel · Liquid-cooled
Large commercial construction, data center temporary power, utility emergency standby, hospital backup, and rental fleet large-frame class.
260 kW prime diesel portable generator. Cummins QSL9-G9-powered with 480-gallon tank and 1,000A main breaker.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G400
Current-generation Tier 4 Final replacement for the legacy G450. Cummins QSG12 with variable-speed cooling fan and 470-gallon tank at value-tier pricing.
374 kW standby · Diesel · Liquid-cooled
Large commercial construction, data center temporary power, utility emergency standby, industrial facilities, and rental fleet large-frame class.
340 kW prime diesel portable generator. Cummins QSG12-powered with 11.8-liter engine and 470-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G450
Legacy Tier 2 with no DPF, no SCR, no DEF — the simplest large-frame maintenance in the lineup. Cummins QSX15 proven reliability at value-tier pricing.
400 kW standby · Diesel · Liquid-cooled
Large construction sites in Tier 2-permissible jurisdictions, mining operations, industrial standby, and rental fleet legacy units still in active service.
375 kW prime diesel portable generator. Cummins QSX15-powered large-frame unit with 574-gallon tank. Legacy Tier 2 model.
Tier 23-phaseconstructionrental-fleet
Echo
Echo DGK125F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
110 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
125 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK125FP
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
110 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
125 kVA parallel-capable portable diesel generator with SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK180F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
158 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
180 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK180FP
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
158 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
180 kVA parallel-capable portable diesel generator with SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK400F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
352 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
400 kVA portable diesel generator. Flagship Echo/Shindaiwa unit with SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Generac
Generac SD100
100 kW industrial diesel with Iveco/FPT 6.7L engine. 10-15% below Kohler at comparable kW. NFPA 110 Level I/II.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for office complexes, hotels, and municipal critical infrastructure.
130 kW industrial diesel with Iveco/FPT engine. 10-15% below Kohler pricing. Digital controller with paralleling capability.
130 kW standby · Diesel · Liquid-cooled
130 kW diesel standby for mid-size commercial, light manufacturing, and healthcare clinics.
130 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD150
150 kW industrial diesel with 10,000+ dealer support network. 10-15% below Kohler pricing. NFPA 110 compliant.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hotels, warehouses, and commercial office buildings.
150 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6 with electronic injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
175 kW diesel standby for large retail, assisted living, and mid-size industrial facilities.
175 kW industrial diesel standby generator. Generac 6.7L turbocharged-aftercooled inline-6 with electronic injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD200
200 kW industrial diesel with Iveco 6.7L engine. 10-15% cost advantage over Kohler. Paralleling-ready controller.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, data centers, and large commercial complexes.
250 kW industrial diesel at 10-15% below Kohler equivalent. Proven Iveco/FPT engine. Largest US dealer network.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, manufacturing plants, and high-rise buildings.
250 kW industrial diesel standby generator. Iveco/FPT 8.7L turbocharged-aftercooled inline-6 with common rail injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD275
275 kW industrial diesel. 10-15% below Kohler at comparable kW. Digital control with paralleling and load management.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for large commercial campuses, water treatment, and healthcare facilities.
275 kW industrial diesel standby generator. Iveco/FPT 10.3L turbocharged-aftercooled inline-6 with common rail injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD300
300 kW industrial diesel with Iveco engine. 10-15% cost advantage vs Kohler. NFPA 110 compliant, paralleling-ready.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, multi-building campuses, and industrial plants.
Factory-direct at 15-30% below major brands. PSI 8.8L high-output turbo V8 + DSE controller — no proprietary lock-in. 3-7 day lead times.
200 kW standby · Natural Gas · Liquid-cooled
200 kW natural gas standby for commercial buildings, hotels, multi-family housing, and data centers.
200 kW natural gas stationary standby generator. Made-in-USA commercial unit with PSI 8.8L high-output turbocharged V8, Stamford alternator, and DSE 7420 MKII controller. NG only.
Factory-direct at 15-30% below major brands. Perkins engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial buildings, telecom sites, pump stations, and light industrial facilities.
100 kW stationary diesel standby generator with Perkins 1104D-E44TAG2 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPD-1500
Factory-direct at 15-30% below major brands. Perkins 7.0L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hospitals, hotels, commercial buildings, and municipal infrastructure.
150 kW stationary diesel standby generator with Perkins 1106D-E70TAG4 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPD-2000
Factory-direct at 15-30% below major brands. Perkins 7.0L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, hotels, water treatment, and mid-size commercial or municipal facilities.
200 kW stationary diesel standby generator with Perkins 1106D-E70TAG5 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPJD-1000
Factory-direct at 15-30% below major brands. John Deere 4045 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, telecom, pump stations, and municipal buyers. Buy American compliant.
100 kW stationary diesel standby generator with John Deere 4045HF285 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPJD-1550
Factory-direct at 15-30% below major brands. John Deere 6068 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
155 kW standby · Diesel · Liquid-cooled
155 kW diesel standby for hospitals, hotels, commercial buildings, and municipal infrastructure. Buy American compliant.
155 kW stationary diesel standby generator with John Deere 6068HF285 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPJD-2100
Factory-direct at 15-30% below major brands. John Deere 6068 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
210 kW standby · Diesel · Liquid-cooled
210 kW diesel standby for hospitals, hotels, water treatment, and commercial facilities. Buy American compliant.
210 kW stationary diesel standby generator with John Deere 6068HF485 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-2500
Factory-direct at 15-30% below major brands. Volvo Penta 7.7L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, hotels, data centers, and mid-size commercial or industrial facilities.
250 kW stationary diesel standby generator with Volvo Penta TAD852GE 7.7L engine. Stamford S4L1D alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-3000
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, hotels, data centers, and large commercial or industrial facilities.
300 kW stationary diesel standby generator with Volvo Penta TAD1351GE 12.8L engine. Stamford S4L1D alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-3500
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for hospitals, data centers, hotels, and large commercial or campus facilities.
350 kW stationary diesel standby generator with Volvo Penta TAD1352GE 12.8L engine. Stamford S4L1DF alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-4000
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for hospitals, data centers, hotels, and large commercial or campus facilities.
400 kW stationary diesel standby generator with Volvo Penta TAD1353GE 12.8L engine. Stamford S4L1DG alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette T4D-1000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta engine + Basler controller — EPA/CARB compliant, no lock-in.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final diesel for air-quality-restricted sites, prime power, and commercial standby in CARB jurisdictions.
100 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD581VE 5.13L engine. SCR aftertreatment, DEF system, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-1500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 7.7L engine + Basler controller — EPA/CARB compliant, no lock-in.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel for air-quality-restricted sites, hospitals, and prime power in CARB jurisdictions.
150 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD881VE 7.7L engine. SCR aftertreatment, DEF system, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-2000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 10.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel for hospitals, municipal sites, construction, and prime power in CARB jurisdictions.
200 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1180VE 10.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-2500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel for hospitals, municipal sites, and prime power in air-quality-restricted CARB jurisdictions.
250 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1381VE 12.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-3000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel for hospitals, municipal infrastructure, and prime power in CARB jurisdictions.
300 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1383VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-3500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
350 kW standby · Diesel · Liquid-cooled
350 kW Tier 4 Final diesel for hospitals, data centers, municipal sites, and prime power in CARB jurisdictions.
350 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1385VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
Tier 4 Final3-phasecommercialhospital
Hipower Systems
Hipower HFW-100
FPT N67 inline-6 diesel at the 100 kW class — EPA Tier 4 Final certified, US-built, with the parts depth of a CNH Industrial engine ecosystem.
100 kW standby · Diesel · Liquid-cooled
Commercial standby power for office buildings, supermarkets, urgent care centers, and small data closets needing 100 kW with California emissions compliance.
100 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT N67 inline-6 diesel at 130 kW — EPA Tier 4 Final, US-built in Kansas, with three-phase and single-phase availability for flexible commercial standby applications.
130 kW standby · Diesel · Liquid-cooled
Industrial and commercial standby for office campuses, food processing, and distribution centers requiring 130 kW with California emissions compliance.
130 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT N67 at its 160 kW apex — EPA Tier 4 Final, single- and three-phase, US-built for demanding commercial and industrial standby in California-regulated environments.
160 kW standby · Diesel · Liquid-cooled
Industrial standby for mid-size manufacturing, multi-tenant office, and healthcare facilities requiring 160 kW with EPA Tier 4 Final certification.
160 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT C87 inline-6 steps up displacement to 8.7L at 180 kW — EPA Tier 4 Final, US-built, with the thermal headroom to handle demanding industrial standby loads.
180 kW standby · Diesel · Liquid-cooled
Industrial standby for manufacturing facilities, large office buildings, and data center support requiring 180 kW three-phase with full California emissions compliance.
180 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
200 kW on the FPT C87 8.7L inline-6 — EPA Tier 4 Final, US-built in Kansas, with Hipower's complete enclosure, controls, and fuel system integration for simplified permit submittals.
200 kW standby · Diesel · Liquid-cooled
Industrial standby and mission-critical backup for data centers, hospitals, and large commercial buildings requiring 200 kW with California emissions compliance.
200 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT C87 inline-6 at 230 kW — EPA Tier 4 Final, US-built, bridging the gap between 200 kW and 250 kW for applications that benefit from the additional headroom.
230 kW standby · Diesel · Liquid-cooled
Industrial standby for large manufacturing, multi-story commercial buildings, and critical infrastructure needing 230 kW three-phase with California emissions compliance.
230 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
250 kW at the top of the FPT C87 range — EPA Tier 4 Final, US-built, with Stamford S4L1D-family alternator and comprehensive enclosure options for demanding industrial and mission-critical standby.
250 kW standby · Diesel · Liquid-cooled
Mission-critical and industrial standby for data centers, hospitals, and large commercial complexes requiring 250 kW three-phase with California emissions compliance.
250 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT C13 12.9L inline-6 steps up to 300 kW with ample displacement headroom — EPA Tier 4 Final, US-built, for mission-critical and large industrial standby in California-regulated environments.
300 kW standby · Diesel · Liquid-cooled
Mission-critical standby for data centers, hospital campuses, large industrial facilities, and multi-building commercial complexes requiring 300 kW three-phase with California emissions compliance.
300 kW standby diesel generator with FPT C13 12.9L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
105 kW diesel standby generator. John Deere 4045HF285 family engine, Stamford UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbylight-commercial
Hipower Systems
Hipower HJW-130
129 kW standby · Diesel · Liquid-cooled
129 kW diesel standby generator. John Deere 4045HF285-147 engine, Stamford UCI 274 F alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-155
155 kW standby · Diesel · Liquid-cooled
155 kW diesel standby generator. John Deere 6068HF285 family engine, Stamford UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-205
205 kW standby · Diesel · Liquid-cooled
205 kW diesel standby generator. John Deere 6068 or 6081 family engine, Stamford UCDI 274 or UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-225
225 kW standby · Diesel · Liquid-cooled
225 kW diesel standby generator. John Deere 6090HF484-258 engine, Stamford HCI 444 D alternator. EPA Tier 3. US manufactured in Lenexa, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-275
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby generator. John Deere 6090HF484-315 engine, Stamford HCI 444 E alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-305
305 kW standby · Diesel · Liquid-cooled
305 kW diesel standby generator. John Deere 6090HF484 family engine, Stamford HCI 444 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-355
355 kW standby · Diesel · Liquid-cooled
355 kW diesel standby generator. John Deere 6090HF484 family engine, Stamford HCI 444 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-410
410 kW standby · Diesel · Liquid-cooled
410 kW diesel standby generator. John Deere 6090HF484 family engine, Stamford HCI 444 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HMW-270
MTU 1600-series engine with 30,000-hour TBO — the benchmark for mission-critical data center and hospital standby applications.
270 kW standby · Diesel · Liquid-cooled
Tier I data centers, hospital campuses, and utility substations requiring NFPA 110 Level 1 life-safety compliance.
270 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-310
MTU 1600-series 10-cylinder engine with 30,000-hour TBO — mission-critical standby at the 300 kW class without the Big 4 price premium.
310 kW standby · Diesel · Liquid-cooled
Tier I data centers, hospital critical branches, and municipal emergency operations centers needing NFPA 110 Level 1 compliance.
310 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-370
MTU 1600-series 12-cylinder engine — more torque and transient response than 10-cylinder alternatives at the same power class.
370 kW standby · Diesel · Liquid-cooled
Data centers, hospitals, and utilities requiring NFPA 110 Level 1 in the 350-400 kW range with seismic and CARB compliance.
370 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-405
MTU 12V1600 12-cylinder engine at the 400 kW class — the highest TBO in its power range, preferred by NorCal data center and hospital procurement teams.
405 kW standby · Diesel · Liquid-cooled
400 kW-class critical standby for Tier I data centers, hospital essential systems, and utility substations in CARB-regulated regions.
405 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HNG-160
CARB-certified large stationary natural gas standby from Hipower's HNG series — utility-supplied fuel, no on-site diesel storage, broad voltage options.
159 kW standby · Natural Gas / LPG · Liquid-cooled
California commercial and industrial buildings in the 150–200 kW class with natural gas service where CARB certification is required.
159 kW stationary natural gas generator with PSI natural gas engine. CARB certified for California standby. Built in Olathe, Kansas.
CARB-certified large stationary natural gas standby from Hipower's HNG series — utility-supplied fuel, no on-site diesel storage, broad voltage options.
208 kW standby · Natural Gas / LPG · Liquid-cooled
California commercial and industrial buildings at 200 kW with natural gas service where CARB certification is required.
208 kW stationary natural gas generator with PSI natural gas engine. CARB certified for California standby. Built in Olathe, Kansas.
CARB-certified large stationary natural gas standby from Hipower's HNG series — utility-supplied fuel, no on-site diesel storage, broad voltage options.
263 kW standby · Natural Gas / LPG · Liquid-cooled
California commercial and industrial buildings at 250+ kW with natural gas service where CARB certification is required.
263 kW stationary natural gas generator with PSI natural gas engine. CARB certified for California standby. Built in Olathe, Kansas.
CARB-certified large stationary natural gas standby from Hipower's HNG series — utility-supplied fuel, no on-site diesel storage, broad voltage options.
354 kW standby · Natural Gas / LPG · Liquid-cooled
California industrial and large commercial buildings at 350 kW with natural gas service where CARB certification is required.
354 kW stationary natural gas generator with PSI natural gas engine. CARB certified for California standby. Built in Olathe, Kansas.
CARB-certified large stationary natural gas standby from Hipower's HNG series — utility-supplied fuel, no on-site diesel storage, broad voltage options.
400 kW standby · Natural Gas / LPG · Liquid-cooled
California industrial and large commercial buildings at 400 kW with natural gas service where CARB certification is required.
400 kW stationary natural gas generator with PSI natural gas engine. CARB certified for California standby. Largest model in Hipower's HNG series.
Trailer-mounted CARB-certified natural gas generator for temporary power — no diesel storage, connects to permanent gas supply on site.
182 kW standby · Natural Gas / LPG · Liquid-cooled
Temporary natural gas power for construction, large events, and commercial outage coverage where 180 kW from a permanent gas supply is needed.
182 kW trailer-mounted natural gas generator with PSI natural gas engine. CARB certified. Rental-ready towable unit for temporary power from a permanent gas supply.
Trailer-mounted CARB-certified natural gas generator for temporary power — no diesel storage, connects to permanent gas supply on site.
235 kW standby · Natural Gas / LPG · Liquid-cooled
Temporary natural gas power for construction, large events, and commercial outage coverage where 235 kW from a permanent gas supply is needed.
235 kW trailer-mounted natural gas generator with PSI natural gas engine. CARB certified. Rental-ready towable unit for temporary power from a permanent gas supply.
Trailer-mounted CARB-certified natural gas generator for temporary power — no diesel storage, connects to permanent gas supply on site.
312 kW standby · Natural Gas / LPG · Liquid-cooled
Temporary natural gas power for large construction, industrial outage coverage, and events where 312 kW from a permanent gas supply is needed.
312 kW trailer-mounted natural gas generator with PSI natural gas engine. CARB certified. Rental-ready towable unit for temporary power from a permanent gas supply.
Trailer-mounted CARB-certified natural gas generator for large temporary power — no diesel storage, connects to permanent gas supply on site.
408 kW standby · Natural Gas / LPG · Liquid-cooled
Large temporary natural gas power for industrial outage coverage, hospital bypass, and major construction where 400+ kW from a permanent gas supply is needed.
408 kW trailer-mounted natural gas generator with PSI natural gas engine. CARB certified. Rental-ready towable unit for large temporary power from a permanent gas supply.
100 kW industrial gaseous -- General Motors Vortec 5.7L with PM alternator, sub-3% THD. No on-site fuel storage required.
100 kW standby · LPG · Liquid-cooled
100 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
100 kW LPG industrial standby generator. Enclosed gaseous standby for commercial and institutional applications requiring clean-burning propane fuel.
3-phasecommercialhealthcare
Kohler
Kohler 100RZGD
100 kW industrial gaseous -- General Motors Vortec 5.7L with PM alternator, sub-3% THD. No on-site fuel storage required.
100 kW standby · LPG · Liquid-cooled
100 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
100 kW LPG industrial standby generator. Open-frame gaseous standby for commercial and industrial applications on propane.
3-phasecommercialhealthcare
Kohler
Kohler 125REOZJ4
THD below 3% at 130 kW -- the healthcare and commercial default. John Deere 6068HG550 with Decision-Maker controller.
130 kW standby · Diesel · Liquid-cooled
130 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
130 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 145REOZT4
130 kW mobile diesel trailer -- Tier 4 John Deere 6068HG550. DOT-towable for large temporary power and emergency deployment.
130 kW standby · Diesel · Liquid-cooled
130 kW mobile standby for large construction projects, event power, emergency response, and planned outage bridge power.
130 kW diesel mobile trailer Tier 4 Final commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 150REOZJ4
THD below 3% at 150 kW -- the healthcare and commercial default. John Deere 6068HG550 with Decision-Maker controller.
150 kW standby · Diesel · Liquid-cooled
150 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
154 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 150REOZJF
THD below 3% at 154 kW -- the healthcare and commercial default. John Deere 6068HF285K with Decision-Maker controller.
154 kW standby · Diesel · Liquid-cooled
154 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
154 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 150REZGC
150 kW industrial gaseous -- PSI 8.8L Industrial with PM alternator, sub-3% THD. No on-site fuel storage required.
150 kW standby · LPG · Liquid-cooled
150 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
150 kW LPG industrial standby generator. Enclosed gaseous standby with PSI engine for mid-range commercial and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 150RZGC
150 kW industrial gaseous -- PSI 8.8L Industrial with PM alternator, sub-3% THD. No on-site fuel storage required.
150 kW standby · LPG · Liquid-cooled
150 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
135 kW LPG industrial standby generator. Open-frame gaseous standby with PSI engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 175REOZT4
150 kW mobile diesel trailer -- Tier 4 John Deere 6068HG550. DOT-towable for large temporary power and emergency deployment.
150 kW standby · Diesel · Liquid-cooled
150 kW mobile standby for large construction projects, event power, emergency response, and planned outage bridge power.
154 kW diesel mobile trailer Tier 4 Final commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 180REOZJG
THD below 3% at 180 kW -- the healthcare and commercial default. John Deere 6068HFG82E with Decision-Maker controller.
180 kW standby · Diesel · Liquid-cooled
180 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
180 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 180REZXB
190 kW industrial gaseous -- Doosan D111TIC with PM alternator, sub-3% THD. No on-site fuel storage required.
190 kW standby · LPG · Liquid-cooled
190 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
190 kW LPG industrial standby generator. Enclosed gaseous standby with Doosan engine for commercial, healthcare, and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 180RZXB
190 kW industrial gaseous -- Doosan D111TIC with PM alternator, sub-3% THD. No on-site fuel storage required.
190 kW standby · LPG · Liquid-cooled
190 kW commercial standby on NG/LP for retail, offices, and light commercial preferring gaseous fuel over diesel.
170 kW LPG industrial standby generator. Open-frame gaseous standby with Doosan engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 200REZXB
200 kW industrial gaseous -- Doosan D111TIC with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
200 kW standby · LPG · Liquid-cooled
200 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
200 kW LPG industrial standby generator. Enclosed gaseous standby with Doosan engine for commercial, healthcare, and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 200RZXB
200 kW industrial gaseous -- Doosan D111TIC with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
200 kW standby · LPG · Liquid-cooled
200 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
175 kW LPG industrial standby generator. Open-frame gaseous standby with Doosan engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 230REOZJE
230 kW diesel standby with sub-3% THD -- John Deere 6090HF484C. Healthcare and data center default in this power class.
230 kW standby · Diesel · Liquid-cooled
230 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
230 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 250REOZJE
255 kW diesel standby with sub-3% THD -- John Deere 6090HF484B. Healthcare and data center default in this power class.
255 kW standby · Diesel · Liquid-cooled
255 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
255 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 250REZXB
260 kW industrial gaseous -- Doosan D146L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
260 kW standby · LPG · Liquid-cooled
260 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
260 kW LPG industrial standby generator. Enclosed gaseous standby with Doosan engine for large commercial and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 250RZXB
260 kW industrial gaseous -- Doosan D146L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
260 kW standby · LPG · Liquid-cooled
260 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
224 kW LPG industrial standby generator. Open-frame gaseous standby with Doosan engine for commercial and industrial facilities.
3-phasecommercialhealthcare
Kohler
Kohler 275REOZJE
280 kW diesel standby with sub-3% THD -- John Deere 6090HF484A. Healthcare and data center default in this power class.
280 kW standby · Diesel · Liquid-cooled
280 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
280 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 300REOZJ
300 kW diesel standby with sub-3% THD -- John Deere 6090HFG86. Healthcare and data center default in this power class.
300 kW standby · Diesel · Liquid-cooled
300 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
300 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 300REZXC
300 kW industrial gaseous -- Doosan D146L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
300 kW standby · Natural Gas · Liquid-cooled
300 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
300 kW natural gas industrial standby generator. Enclosed gaseous standby with Doosan engine for large commercial and institutional applications.
3-phasecommercialhealthcare
Kohler
Kohler 300REZXC (300 kW Gas)
300 kW industrial gaseous -- Doosan 14.6L (Kohler PN GM64103) with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
300 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
300 kW gaseous-fueled commercial standby generator. Kohler/Rehlko 300REZXC large industrial gaseous unit for major facilities, paralleling applications, and campus power. Note: the 300 kW Kohler gas genset is sold as the 300REZXC, not as 'KG300'.
300 kW industrial gaseous -- PSI/Doosan D183L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
300 kW standby · LPG · Liquid-cooled
300 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
300 kW LPG industrial standby generator. Enclosed gaseous standby with PSI/Doosan engine and pilot-excited permanent-magnet alternator.
3-phasecommercialhealthcare
Kohler
Kohler 300RZXD
300 kW industrial gaseous -- PSI/Doosan D183L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
300 kW standby · LPG · Liquid-cooled
300 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
264 kW LPG industrial standby generator. Open-frame gaseous standby with PSI/Doosan engine and pilot-excited permanent-magnet alternator.
3-phasecommercialhealthcare
Kohler
Kohler 350REOZJ
350 kW diesel standby with sub-3% THD -- John Deere 6135HF485T. Healthcare and data center default in this power class.
350 kW standby · Diesel · Liquid-cooled
350 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJB
360 kW diesel standby with sub-3% THD -- John Deere 6135HFG84B. Healthcare and data center default in this power class.
360 kW standby · Diesel · Liquid-cooled
360 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJC
350 kW diesel standby with sub-3% THD -- John Deere 6135HF485T. Healthcare and data center default in this power class.
350 kW standby · Diesel · Liquid-cooled
350 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJD
360 kW diesel standby with sub-3% THD -- John Deere 6135HFG84B. Healthcare and data center default in this power class.
360 kW standby · Diesel · Liquid-cooled
360 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REZXB
355 kW industrial gaseous -- Doosan D183TIC with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
355 kW standby · LPG · Liquid-cooled
355 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
355 kW LPG industrial standby generator. Enclosed gaseous standby with Doosan engine and pilot-excited permanent-magnet alternator.
3-phasecommercialhealthcare
Kohler
Kohler 350REZXD
355 kW industrial gaseous -- PSI/Doosan D183L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
355 kW standby · LPG · Liquid-cooled
355 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
355 kW LPG industrial standby generator. Enclosed gaseous standby with PSI/Doosan engine and pilot-excited permanent-magnet alternator.
3-phasecommercialhealthcare
Kohler
Kohler 350RZXD
355 kW industrial gaseous -- PSI/Doosan D183L with PM alternator. No fuel storage, no SPCC plan, lower emissions than diesel.
355 kW standby · LPG · Liquid-cooled
355 kW commercial standby on NG/LP for mid-to-large commercial, multi-tenant buildings, and institutional applications.
290 kW LPG industrial standby generator. Open-frame gaseous standby with PSI/Doosan engine and pilot-excited permanent-magnet alternator.
3-phasecommercialhealthcare
Kohler
Kohler 400REOZJ
400 kW diesel standby with sub-3% THD -- John Deere 6135HF485S. Healthcare and data center default in this power class.
400 kW standby · Diesel · Liquid-cooled
400 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
400 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 400REOZJC
400 kW diesel standby with sub-3% THD -- John Deere 6135HF485S. Healthcare and data center default in this power class.
400 kW standby · Diesel · Liquid-cooled
400 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
400 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 400REOZJD
410 kW diesel standby with sub-3% THD -- John Deere 6135HFG84A. Healthcare and data center default in this power class.
410 kW standby · Diesel · Liquid-cooled
410 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
410 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 400REZXB (400 kW Gas)
400 kW industrial gaseous -- Doosan D219TIC (PSI 21.9L) with PM alternator, sub-3% THD. No fuel tank, no SPCC, lower emissions than diesel.
400 kW gaseous standby for large commercial, industrial, and campus applications where NG eliminates diesel logistics and permitting.
400 kW gaseous-fueled commercial standby generator. Kohler/Rehlko 400REZXB — the flagship of Kohler's industrial gaseous lineup for large facilities and paralleling arrays. Note: the 400 kW Kohler gas genset is sold as the 400REZXB, not as 'KG400'.
100 kW commercial standby on NG/LP for mid-size commercial, multi-family, and light industrial with reliable gas supply.
100 kW gaseous-fueled commercial standby generator. Upper-mid-range industrial gaseous unit for larger commercial facilities on natural gas or propane.
WhisperWatt 125 kVA — 66 dBA at 7m, Isuzu BR-4HK1X 5.2L, 169-gal tank for 24-hr runtime at full load. DEF/SCR Tier 4 Final.
110 kW standby · Diesel · Liquid-cooled
Large portable at 100 kW prime. Diesel at 7.11 gph, 169-gal tank minimizes refueling, commercial backup and large events.
125 kVA (100 kW prime) portable diesel generator. Mid-large WhisperWatt Super-Silent for commercial construction, events, and emergency power.
Tier 4 Final3-phaseconstruction-largerental-fleet
MQ Power
MQ Power DCA-150 WhisperWatt
WhisperWatt 150 kVA — John Deere 6068HFG05 6.8L inline-6, 66 dBA, 319-gal tank for 36-hr full-load runtime. JD dealer network parts.
132 kW standby · Diesel · Liquid-cooled
Major construction/disaster recovery at 120 kW prime. Diesel at 8.9 gph, 319-gal tank for 5-7 day deployments, Tier 4 Final.
150 kVA (120 kW prime) portable diesel generator. John Deere-powered WhisperWatt Super-Silent for major construction, large events, and emergency commercial power.
WhisperWatt 300 kVA — JD 6090HFG06 9.0L inline-6, 72 dBA, 430-gal tank, paralleling capable. Largest JD-powered WhisperWatt.
264 kW standby · Diesel · Liquid-cooled
Major construction/disaster recovery at 240 kW prime. Diesel at 16.7 gph, 430-gal tank for multi-day ops, data center temp power.
300 kVA (240 kW prime) portable diesel generator. Large WhisperWatt for major construction, events, and emergency commercial power.
Tier 4 Final3-phaseconstruction-majorrental-fleet
MQ Power
MQ Power DCA-400 WhisperWatt
WhisperWatt 400 kVA — top of lineup. Isuzu BG-6WG1X 6-cyl, 69 dBA (quieter than DCA-300), CARB compliant for California job sites.
336 kW standby · Diesel · Liquid-cooled
Largest WhisperWatt at 320 kW prime. Diesel at 22.5 gph, 405-gal tank, CARB + Tier 4 Final, infrastructure and data center temp.
400 kVA (320 kW prime) portable diesel generator. The largest WhisperWatt Super-Silent for major construction, infrastructure, and large-scale emergency power.
Tier 4 Final3-phaseconstruction-majorrental-fleet
M
MTU
MTU 4R0113 DS100
100 kW diesel standby with turbo JD 4045HF285 and JDEC electronic isochronous governor (±0.25%). SCAQMD certified, OSHPD eligible.
100 kW standby · Diesel · Liquid-cooled
Commercial/healthcare standby at 100 kW. Diesel at 8.2 gph, SCAQMD + NFPA 110 single-step load, data center edge.
100 kW EPA Tier 3 diesel standby generator with John Deere 4045HF285 engine, 4.5 L turbocharged-aftercooled 4-cylinder, JDEC electronic isochronous governor.
Tier 33-phasecommercial-standbylight-industrial
M
MTU
MTU 6R0113 DS150
150 kW diesel standby on JD 6068HF285 inline-6. Smoother vibration than 4-cyl alternatives, SCAQMD certified, OSHPD eligible, 11.8 gph.
150 kW standby · Diesel · Liquid-cooled
Healthcare and commercial standby at 150 kW. Diesel at 11.8 gph, 6-cyl smooth operation, NFPA 110 single-step load.
150 kW EPA Tier 3 diesel standby generator with John Deere 6068HF285 engine, 6.8 L turbocharged-aftercooled 6-cylinder inline, JDEC governor, 1800 rpm.
Tier 33-phasecommercial-standbylight-industrial
M
MTU
MTU 6R0113 DS200
200 kW diesel standby — max output from the JD 6068 platform. 15.5 gph, SCAQMD certified, OSHPD eligible, isochronous ±0.25%.
200 kW standby · Diesel · Liquid-cooled
Healthcare and commercial standby at 200 kW. Diesel at 15.5 gph, highest R-series inline output, data center edge.
200 kW EPA Tier 3 diesel standby generator with John Deere 6068HFG85 engine, 6.8 L turbocharged 6-cylinder inline, JDEC electronic isochronous governor, 1800 rpm.