Winco · DR Series

Winco DR130F4

130 kW standby / 123 kW prime · Diesel · Liquid-cooled

130 kW standby diesel generator with FPT engine and Stamford alternator. DR series enclosed. US-made.

Winco Winco DR130F4 generator — specifications and details
Standby power
130 kW / 123 kW prime
Voltage options
277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
FPT Industrial N67 · 6.7L
EPA / Emissions
Tier 4 Final
Alternator
Stamford HCI 444

Overview#

The Winco DR130F4 is a 130 kW standby / 123 kW prime diesel generator powered by an FPT Industrial N67-family 6.7-liter six-cylinder turbocharged diesel engine with a Stamford HCI 444 alternator. A three-phase-only unit (277/480V), it is among the largest models in Winco's enclosed DR diesel standby series. EPA Tier 4 Final certified. 100% US-made in Le Center, Minnesota.

At 130 kW, the DR130F4 serves facilities with significant commercial electrical loads — large buildings, healthcare facilities, and municipal infrastructure where reliable diesel standby is a code requirement.

The American Manufacturing Advantage#

At 130 kW, most diesel standby generators in this class use overseas engine platforms (Volvo Penta, MTU, or imported Cummins variants). The DR130F4 is different: FPT Industrial N67 — a CNH Industrial engine built in industrial facilities that serve global OEMs — paired with a Stamford HCI-series alternator, assembled entirely at Winco's Le Center, Minnesota facility.

For healthcare systems, universities, and government agencies subject to Buy American Act provisions, the DR130F4 provides 130 kW of US-manufactured standby infrastructure. The FPT N67 engine is distributed globally through Case IH, New Holland, and independent diesel dealers — parts availability is strong, and service does not require a dedicated Winco dealer.

Service & Maintenance#

Oil and fuel filter changes every 500 hours or annually. At 130 kW, the N67 six-cylinder engine has a larger oil capacity than mid-range four-cylinder platforms — budget accordingly for consumable costs. Standby fuel degradation makes the annual change interval mandatory regardless of hours logged.

The Stamford HCI-series alternator requires periodic brush, bearing, and insulation inspection — standard tasks for commercial generator technicians. Transfer switch contacts should be exercised weekly. Major overhaul at 20,000 hours.

Our Service Experience#

PowerGen services Winco DR units throughout the Bay Area and Northern California. At 130 kW, the DR130F4 is in a class where Cummins, Caterpillar, and Kohler dominate. Winco's advantage is specific: US manufacturing and non-proprietary components for clients with procurement requirements that the major brands cannot satisfy. Our service capability on the DR130F4 matches that of any major-brand diesel standby — FPT Industrial and Stamford parts come through standard commercial generator supply channels.

Request a quote

Get pricing & lead time on the Winco DR130F4

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Winco DR130F4

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

28.5 hours(1.2 days)

Fuel consumption ≈ 7.02 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Winco DR130F4 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel filterExtended standby fuel degradation — change annually regardless of hours500+minor
Starting batteryCapacity loss in standby — float charge, test annually4,380+minor
Transfer switch contactsOxidation on standby generators — exercise weekly to maintain contact quality8,760+minor

Frequently Asked Questions

What is the standby kW rating of the DR130F4?
The DR130F4 is rated at 130 kW standby / 123 kW prime. It is a three-phase-only unit (277/480V).
What engine does the DR130F4 use?
The DR130F4 uses an FPT Industrial N67-family 6.7-liter six-cylinder turbocharged diesel engine from CNH Industrial. The N67 is the same engine family used in larger Case IH and New Holland agricultural equipment and is widely supported globally.
What makes Winco different from Generac or Kohler?
Winco uses non-proprietary FPT Industrial engines and Stamford alternators — both globally serviceable without OEM-specific tools or programs. Winco has manufactured 100% in Le Center, Minnesota since 1927. Cummins, Generac, and Kohler use proprietary or semi-proprietary engines and offer connected monitoring and larger dealer networks, but with parts and service lock-in.
Is the DR130F4 EPA Tier 4 Final compliant?
Yes. The DR130F4 carries EPA Tier 4 Final certification, meeting current non-road diesel emissions standards.
Where are Winco generators made?
100% in Le Center, Minnesota. Winco has operated at that US facility since 1927, the longest continuous run of any US generator manufacturer.
What are the service intervals for the DR130F4?
Oil and fuel filter changes every 500 hours or annually. Air filter inspection at 500 hours. Major overhaul at 20,000 hours. Transfer switch contacts should be exercised weekly during standby operation.
Who services Winco generators in Northern California?
PowerGen services Winco DR units throughout the Bay Area and Northern California. The FPT Industrial N67 engine and Stamford alternator are non-proprietary, so we source parts through standard diesel supply channels and service the DR130F4 the same way we would any commercial diesel standby generator.

More in the DR Series

USA-made Tier 4 diesel standby in enclosed packages — 13 to 175 kW on FPT and Isuzu engines.

Similar models

Winco Winco DR100F4 100 kW liquid-cooled standby generator

Winco

Winco DR100F4

100% US-made diesel standby with Stamford alternator and non-proprietary engines — serviceable by anyone, not locked to a dealer network.

100 kW standby · Diesel · Liquid-cooled

100 kW standby diesel generator with FPT engine and Stamford alternator. DR series enclosed. US-made.

Tier 4 Final3-phasecommercial-standby
Winco Winco DR175F4 175 kW liquid-cooled standby generator

Winco

Winco DR175F4

100% US-made diesel standby with Stamford alternator and non-proprietary engines — serviceable by anyone, not locked to a dealer network.

175 kW standby · Diesel · Liquid-cooled

175 kW standby diesel generator with FPT engine and Stamford alternator. Largest DR series unit. US-made.

Tier 4 Final3-phasecommercial-standby
Generac Generac SD130 130 kW liquid-cooled standby generator

Generac

Generac SD130

130 kW industrial diesel with Iveco/FPT engine. 10-15% below Kohler pricing. Digital controller with paralleling capability.

130 kW standby · Diesel · Liquid-cooled

130 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.

3-phasecommercial-standbylight-industrial

Need service or parts for the Winco DR130F4?

We service every major OEM and stock genuine parts for the most common models.