Diesel is the dominant fuel for commercial and industrial standby power above 60 kW. It offers high energy density (≈138,000 BTU/gal vs ≈1,000 BTU/cf for natural gas), fast load acceptance, on-site fuel storage that's independent of utility infrastructure, and well-understood maintenance economics. The trade-offs are EPA Tier emissions compliance, fuel polishing requirements, and the operational cost of maintaining a diesel inventory. Below are diesel generator models we service and maintain in the field, with manufacturer specifications and our own service-interval observations.
341 models in this category.
Need help selecting a diesel backup generators?
Our application engineers help size, spec, and source backup power for commercial, industrial, and mission-critical sites.
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
110 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
125 kVA hybrid energy system with 65 kWh LTO battery storage. Diesel-battery hybrid for reduced fuel and emissions.
3-phaseconstructionrental-fleet
Airman
Airman EBOSS 220-125
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
194 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
220 kVA hybrid energy system with 125 kWh LTO battery storage. Diesel-battery hybrid for large sites.
3-phaseconstructionrental-fleet
Airman
Airman EBOSS 25-25
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
22 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
25 kVA hybrid energy system with 25 kWh LTO battery storage. Diesel-battery hybrid for reduced fuel and emissions.
3-phaseconstructionrental-fleet
Airman
Airman EBOSS 400-220
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
336 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
400 kVA hybrid energy system with 220 kWh LTO battery storage. Flagship diesel-battery hybrid.
3-phaseconstructionrental-fleet
Airman
Airman EBOSS 70-45
Only integrated diesel-battery hybrid portable generator on the market — LTO batteries, unlimited paralleling, dramatic fuel and emissions reduction.
60 kW standby · Diesel · Liquid-cooled
Noise-sensitive urban construction, events, and sites where fuel cost and emissions matter.
70 kVA hybrid energy system with 45 kWh LTO battery storage. Diesel-battery hybrid for reduced fuel and emissions.
3-phaseconstructionrental-fleet
Airman
Airman SDG125
0.001% warranty claim rate, 110% fluid containment standard, 23.3-hr runtime at 100 kW — premium Isuzu-powered reliability for serious commercial and emergency standby applications.
110 kW standby · Diesel · Liquid-cooled
Full-size 100 kW portable for large commercial construction, emergency standby, data center temporary power, and infrastructure projects requiring overnight unattended operation.
100 kW prime diesel portable generator. Isuzu BR-4HK1X engine with 23.3-hour runtime, 110% fluid containment, and switchable output.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG13
0.001% warranty claim rate, 110% fluid containment standard, Kubota D1503 reliability — lowest total cost of ownership in the compact 10 kW portable class.
11 kW standby · Diesel · Liquid-cooled
Compact 10 kW portable for tight-access construction sites, overnight event power, and small commercial temporary loads where space and environmental compliance matter.
10 kW prime diesel portable generator. Ultra-compact Kubota-powered unit with 110% fluid containment and 27.7-hour runtime.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG150
0.001% warranty claim rate, 110% fluid containment standard, 66 dBA at 7m, 24-hr runtime at 120 kW — John Deere 6068 reliability with Hokuetsu precision engineering.
132 kW standby · Diesel · Liquid-cooled
Full-size 120 kW portable for large commercial construction, emergency standby, and noise-sensitive urban applications where the 66 dBA rating and environmental compliance are required.
120 kW prime diesel portable generator. John Deere 6068-powered with 24-hour runtime, 66 dBA operation, and 110% fluid containment.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG220S
Industry-leading 0.001% warranty claim rate with 110% fluid containment standard — no separate secondary containment needed on CA sites.
194 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites requiring ultra-reliability and environmental compliance.
220 kVA (176 kW prime) portable diesel generator with 110% fluid containment and John Deere engine.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG25
0.001% warranty claim rate, 110% fluid containment standard, 32-hr runtime — the longest in the 20 kW portable class. Isuzu turbo diesel with lowest total cost of ownership.
22 kW standby · Diesel · Liquid-cooled
Workhorse 20 kW portable for construction sites, film production, and event power where extended runtime and environmental compliance eliminate downtime and aftermarket add-ons.
20 kW prime diesel portable generator. Isuzu-powered with 32-hour runtime, 110% fluid containment, and switchable single/three-phase output.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG25SV V-Pump
Industry-leading 0.001% warranty claim rate with 110% fluid containment standard — no separate secondary containment needed on CA sites.
22 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites requiring ultra-reliability and environmental compliance.
25 kVA (20 kW prime) portable diesel generator with integrated VFD for motor starting and dewatering.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG40
0.001% warranty claim rate, 110% fluid containment standard, 37-hr runtime in the same footprint as the SDG25 — maximum power density with lowest total cost of ownership.
30 kW standby · Diesel · Liquid-cooled
Mid-range 29 kW portable for construction sites needing more power without a larger footprint. Ideal for commercial TI projects, utility work, and multi-day unattended temporary power.
28.6 kW prime diesel portable generator. Kubota-powered with 37-hour runtime at full load and 110% fluid containment standard.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG45
0.001% warranty claim rate, 110% fluid containment standard, 28.75-hr runtime at 36 kW — premium Japanese precision at the sweet spot for mid-size commercial portable power.
39 kW standby · Diesel · Liquid-cooled
Mid-size 36 kW portable for commercial construction, large event power, and temporary building services where 20 kW is not enough and 50 kW is oversized.
36 kW prime diesel portable generator. Isuzu 4LE2X engine with 28.75-hour runtime and 110% fluid containment standard.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG45SV V-Pump
Industry-leading 0.001% warranty claim rate with 110% fluid containment standard — no separate secondary containment needed on CA sites.
39 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites requiring ultra-reliability and environmental compliance.
45 kVA (36 kW prime) portable diesel generator with integrated VFD for motor starting and dewatering.
Tier 4 Final3-phaseconstructionrental-fleet
Airman
Airman SDG65
0.001% warranty claim rate, 110% fluid containment standard, 28.5-hr runtime at 51 kW — bridges the gap between compact towables and large trailer units with premium Isuzu reliability.
55 kW standby · Diesel · Liquid-cooled
Mid-size 51 kW portable for commercial construction, emergency standby, and event power where loads exceed 36 kW but a full-size 100 kW trailer is unnecessary.
51 kW prime diesel portable generator. Isuzu 4JJ1X engine with 28.5-hour runtime, 111-gallon tank, and 110% fluid containment.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 125
±0.25% voltage regulation, 500-hr service intervals, 166-gal tank for extended runtime at 100 kW prime
110 kW standby · Diesel · Liquid-cooled
Large construction sites, emergency temporary power, and rental fleet deployment needing 100 kW portable output
100 kW prime diesel portable generator. John Deere 4045-powered with 73 dBA operation, Leroy Somer alternator, and 166-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 150
70 dBA — quieter than its 100 kW sibling, 335-gal tank for 43+ hr runtime, dual 50/60 Hz capability
132 kW standby · Diesel · Liquid-cooled
Large construction, infrastructure projects, and extended-runtime temporary power needing 120 kW with minimal refueling
120 kW prime diesel portable generator. John Deere 6068-powered with 70 dBA operation, 335-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 175
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
154 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
175 kVA (140 kW prime) portable diesel generator. Swedish-engineered QAS series with FPT engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 200
71 dBA — quiet for 160 kW class, shared 6068 platform with QAS 150 for fleet parts commonality, 36+ hr runtime
176 kW standby · Diesel · Liquid-cooled
Large construction, infrastructure, and rental fleet operations needing 160 kW portable power with platform commonality
160 kW prime diesel portable generator. John Deere 6068-powered with 71 dBA operation, 335-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 235
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
206 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
234 kVA (187 kW prime) portable diesel generator. Swedish-engineered QAS series with FPT engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 250
73 dBA — competitive for 200 kW class, 385-gal tank for 34+ hr runtime, 800A breaker, shared platform with QAS 330
220 kW standby · Diesel · Liquid-cooled
Heavy construction, utility temporary power, and data center backup needing 200 kW portable output with extended runtime
200 kW prime diesel portable generator. John Deere-powered with 73 dBA operation, 385-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 330
73 dBA — same noise as QAS 250 with 32% more power, shared 9.0L platform for fleet parts commonality, 25+ hr runtime
290 kW standby · Diesel · Liquid-cooled
Heavy construction, data center temporary power, and large commercial operations needing 250+ kW portable output
264 kW prime diesel portable generator. John Deere-powered with 73 dBA operation, 385-gallon tank, and Leroy Somer alternator.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 410
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
361 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
410 kVA (328 kW prime) portable diesel generator. Swedish-engineered QAS series with Scania engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 625
300% overcurrent for motor starting, SCR-only aftertreatment (no DPF), 707-gal tank, 26,000 lb tri-axle mobile platform
550 kW standby · Diesel · Liquid-cooled
Large construction, data center temporary power, and emergency standby needing 500 kW mobile output with motor-starting capability
500 kW prime diesel portable generator. Volvo TWD1672GE-powered flagship with 707-gallon tank, AREP excitation, and 300% overcurrent capability.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 70
67 dBA — 5 dB quieter than peers, ±0.25% voltage regulation, 110-gal tank for 25+ hr runtime
60 kW standby · Diesel · Liquid-cooled
Mid-size portable power for construction, temporary power, and events needing 50-60 kW with low noise
56 kW prime diesel portable generator. Isuzu 4JJ1X engine with 67 dBA operation, Leroy Somer alternator, and 110-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 700
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
616 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
700 kVA (560 kW prime) portable diesel generator. Flagship Swedish-engineered QAS series with Volvo 16.1L engine.
Tier 4 Final3-phaseconstructionrental-fleet
Atlas Copco
Atlas Copco QAS 95
Swedish-engineered QAS series — 5-8 dB quieter than competitors with best fuel efficiency and runtime in class.
83 kW standby · Diesel · Liquid-cooled
Rental fleets in Atlas Copco compressor ecosystem, noise-restricted urban construction, and events.
95 kVA (76 kW prime) portable diesel generator. Swedish-engineered QAS series with John Deere engine.
Tier 4 Final3-phaseconstructionrental-fleet
Blue Star Power Systems
Blue Star JD100-01
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, multi-family, and municipal facilities where value engineering and service-tech independence matter.
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine with charge air cooling, Stamford UCI274 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD150-01
Open Basler controller + John Deere 6068 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and component independence matter.
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HF285 6-cylinder engine, Stamford UCI274/UCDI274 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD200-01
Open Basler controller + John Deere 6068 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for value-engineering projects, municipal facilities, and service-savvy buyers who prioritize component independence.
200 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HFG85 6-cylinder engine, Stamford S4L1S/UCDI274 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD250-02
Open Basler controller + John Deere 6090 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for commercial, institutional, and campus facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HF484 9.0L 6-cylinder engine, Stamford S4L1S/S4L1D alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD275-02
Open Basler controller + John Deere 6090 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
275 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HF484 9.0L 6-cylinder engine, Stamford S4L1S alternator, DSE DCP7310 controller. Three-phase only.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD30-03IT4
Open Basler controller + John Deere engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
30 kW standby · Diesel · Liquid-cooled
30 kW diesel standby for small commercial, retail, and light-duty applications where component independence and easy serviceability matter.
30 kW Tier 4 Interim diesel standby generator built by Blue Star Power Systems. John Deere 3029TFG89 engine, Stamford S1L2 alternator, DSE DCP7310 controller.
Tier 4 Interim3-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD300-02
Open Basler controller + John Deere 6090 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for large commercial, campus, and municipal facilities where value engineering and non-proprietary component access matter.
300 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6090HFG86 9.0L 6-cylinder engine, Stamford S4L1D alternator, DSE DCP7310 controller. Three-phase only.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star JD40-03
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
40 kW standby · Diesel · Liquid-cooled
40 kW diesel standby for small commercial, retail, and light-duty facilities where component independence and value engineering matter.
40 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045TF280 engine, Stamford UCI224 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD40-05FT4
Open Basler controller + John Deere engine + Stamford alternator — no proprietary lock-in. Tier 4 Final compliant, serviceable by any qualified tech.
40 kW standby · Diesel · Liquid-cooled
40 kW Tier 4 Final diesel standby for small commercial and light-duty facilities requiring current emissions compliance.
40 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 3029HG530 2.9L inline-three with DOC/DPF, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star JD40-05FT4MP
Open Basler controller + John Deere engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
40 kW standby · Diesel · Liquid-cooled
40 kW Tier 4 Final mobile diesel for construction sites, emergency response, and temporary power where portability and clean emissions matter.
40 kW Tier 4 Final mobile trailer diesel generator built by Blue Star Power Systems. John Deere 3029HG530 three-cylinder engine, Stamford UCI224D alternator, DSE DCP7310 controller, 130-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star JD50-03
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
50 kW standby · Diesel · Liquid-cooled
50 kW diesel standby for small commercial, retail, worship, and light-industrial sites prioritizing component independence over brand premium.
50 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045TF280 engine, Stamford UCI224 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD60-02
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for light commercial, retail, multi-family, and telecom sites where value engineering and open-source components matter.
60 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045TF280 engine, Stamford UCI224 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star JD60-04FT4
Open Basler controller + John Deere engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
60 kW standby · Diesel · Liquid-cooled
60 kW Tier 4 Final diesel standby for commercial and light-industrial facilities requiring current emissions compliance and component independence.
60 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 4045HFG04 4.5L inline-four with SCR/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star JD60-04FT4MP
Open Basler controller + John Deere engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
60 kW standby · Diesel · Liquid-cooled
60 kW Tier 4 Final mobile diesel for construction sites, emergency response, and temporary power where portability and clean emissions matter.
60 kW Tier 4 Final mobile trailer diesel generator built by Blue Star Power Systems. John Deere 4045HFG04 four-cylinder engine, Stamford UCI224F alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star JD80-02
Open Basler controller + John Deere 4045 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial, multi-family, and municipal facilities where value engineering and service-tech independence matter.
80 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine with charge air cooling, Stamford UCI274/UCI224 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star JD80-03FT4
Open Basler controller + John Deere engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
80 kW standby · Diesel · Liquid-cooled
80 kW Tier 4 Final diesel standby for commercial, multi-family, and institutional facilities requiring current emissions and component independence.
80 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. John Deere 4045HFG04 4.5L inline-four with SCR/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star JD80-03FT4MP
Open Basler controller + John Deere engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
80 kW standby · Diesel · Liquid-cooled
80 kW Tier 4 Final mobile diesel for construction, emergency response, and planned outage support where portability and clean emissions matter.
80 kW Tier 4 Final mobile trailer diesel generator built by Blue Star Power Systems. John Deere 4045HFG04 four-cylinder engine, Stamford UCI274C alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star MD1000-01
Open Basler controller + Mitsubishi V12 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component independence matter.
1000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12H-Y2PTAW-1 37.1L V12 engine, Stamford S6L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD1250-01
Open Basler controller + Mitsubishi V12 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for industrial, data center, and utility-scale applications where value engineering and open-architecture components matter.
1250 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12R-Y2PTAW-1 49.0L V12 engine, Stamford S6L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD1600-01
Open Basler controller + Mitsubishi V16 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW diesel standby for industrial, data center, and utility-scale applications where value engineering and non-proprietary components matter.
1600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW-1 65.4L V16 engine, Stamford S7L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD2000-01
Open Basler controller + Mitsubishi V16 engine + Stamford alternator — no proprietary lock-in. 2 MW class without OEM dealer dependency.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for data centers, hospitals, and utility-scale applications where component independence and value engineering matter.
2000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW2-1 65.4L V16 engine, Stamford S7L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD800-01
Open Basler controller + Mitsubishi V12 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for industrial plants, campus power, and data centers where value engineering and non-proprietary component access matter.
800 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12A2-Y2PTAW-2 33.9L V12 engine, Stamford S6L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star PD100-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, institutional, and municipal facilities where Perkins parts access and non-proprietary components matter.
100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, Stamford UCI274C alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD125-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
125 kW standby · Diesel · Liquid-cooled
125 kW diesel standby for commercial, institutional, and municipal facilities where Perkins parts access and component independence matter.
125 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274E alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD150-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and Perkins global parts access matter.
150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274F alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD180-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
180 kW standby · Diesel · Liquid-cooled
180 kW diesel standby for commercial, institutional, and municipal facilities where value engineering and Perkins global parts access matter.
180 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG4 six-cylinder engine with charge air cooling, Stamford UCI274G alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD20-01IT4
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
17 kW standby · Diesel · Liquid-cooled
17 kW diesel standby for small retail, telecom shelters, and light commercial sites needing compact backup with off-the-shelf components.
17 kW Tier 4 Interim diesel standby generator built by Blue Star Power Systems. Perkins 404D-22G naturally aspirated engine, Stamford S1L2-J41 alternator, DSE DCP7310 controller.
Tier 4 Interim3-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star PD200-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for value-engineering projects, municipal facilities, and service-savvy buyers who prioritize component independence.
200 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG5 six-cylinder engine with charge air cooling, Stamford UCI274H alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD250-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1706D-E93TAG1 six-cylinder engine with charge air cooling, Stamford S4L1D-C41 alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD30-01IT4
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
25 kW standby · Diesel · Liquid-cooled
25 kW diesel standby for small commercial, retail, and light-duty sites needing compact backup with globally sourced Perkins components.
25 kW Tier 4 Interim diesel standby generator built by Blue Star Power Systems. Perkins 404D-22TAG turbocharged intercooled engine, Stamford S1L2-J41 alternator, DSE DCP7310 controller.
Tier 4 Interim3-phaselight-commercialsmall-office
Blue Star Power Systems
Blue Star PD300-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
300 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1706D-E93TAG2 six-cylinder engine with charge air cooling, Stamford S4L1D-D41 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star PD350-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for large commercial, industrial, and campus facilities where Perkins parts access and component independence matter.
350 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2206D-E13TAG2 six-cylinder engine with charge air cooling, Stamford S4L1D-E41 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star PD400-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for industrial, campus, and data center facilities where value engineering and non-proprietary component access matter.
400 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2206D-E13TAG3 six-cylinder engine with charge air cooling, Stamford S4L1D-F41 alternator, DSE DCP7310 controller.
Tier 33-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star PD450-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
450 kW standby · Diesel · Liquid-cooled
450 kW diesel standby for industrial, campus, and data center facilities where value engineering and open-architecture components matter.
450 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2506D-E15TAG1 six-cylinder engine with charge air cooling, Stamford HCI534C alternator, DSE DCP7310 controller.
Tier 33-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD50-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
50 kW standby · Diesel · Liquid-cooled
50 kW diesel standby for small commercial, worship, and light-industrial sites prioritizing Perkins global parts availability and value engineering.
50 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-44TG1 turbocharged engine, Stamford UCI224D alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD500-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for industrial, data center, and campus facilities where value engineering and non-proprietary component access matter.
500 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2506C-E15TAG3 six-cylinder engine with charge air cooling, Stamford HCI534D alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD550-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for industrial, data center, and campus facilities where value engineering and open-architecture components matter.
550 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2506C-E15TAG4 six-cylinder engine with charge air cooling, Stamford HCI534E alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD60-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for light commercial, retail, and multi-family sites where Perkins global parts network and component independence matter.
60 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TG1 electronically injected turbocharged engine, Stamford UCI224E alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star PD600-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TAG3 six-cylinder engine with charge air cooling, Stamford HCI534E alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD750-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for industrial, data center, and mission-critical facilities where value engineering and non-proprietary components matter.
750 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TTAG7 twin-turbocharged six-cylinder engine, Stamford S6L1D-C alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD80-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial, multi-family, and municipal sites where Perkins global parts availability and value engineering matter.
80 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, Stamford UCI224G alternator, DSE DCP7310 controller.
Tier 33-phaselight-commercialcommercial
Blue Star Power Systems
Blue Star VD100-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
100 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD581VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star VD100-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final mobile diesel for construction, emergency response, and temporary power where portability and clean emissions matter.
100 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD581VE four-cylinder engine, Stamford UCI274D alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD125-02FT4
Open Basler DGC-2020 controller + Volvo Penta engine + Stamford alternator — Tier 4 Final, no proprietary lock-in. Serviceable by any qualified tech.
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
125 kW Tier 4 Final diesel standby generator from Blue Star Power Systems. Volvo Penta TAD572VE engine with charge-air cooling, paired with Basler DGC-2020 controller.
Tier 4 Final3-phasecommerciallight-industrial
Blue Star Power Systems
Blue Star VD125-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final diesel standby for commercial and institutional facilities requiring current emissions compliance and component independence.
125 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD582VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommercialsmall-commercial
Blue Star Power Systems
Blue Star VD125-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
125 kW standby · Diesel · Liquid-cooled
125 kW Tier 4 Final mobile diesel for construction, emergency response, and temporary power where portability and clean emissions matter.
125 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD582VE four-cylinder engine, Stamford UCI274E alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD150-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel standby for commercial, institutional, and municipal facilities requiring current emissions and component independence.
150 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD881VE 7.7L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD150-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final mobile diesel for construction, planned outage support, and temporary power requiring portability and clean emissions.
150 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD881VE six-cylinder engine, Stamford UCI274F alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD200-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel standby for commercial, institutional, and campus facilities requiring current emissions and component independence.
200 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1180VE 10.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD200-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final mobile diesel for construction, planned outage support, and temporary power requiring portability and clean emissions.
200 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1180VE six-cylinder engine, Stamford UCDI274J1 alternator, DSE DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD230-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
230 kW standby · Diesel · Liquid-cooled
230 kW diesel standby for commercial, institutional, and campus facilities where value engineering and non-proprietary component access matter.
230 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD851GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-03
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for large commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
250 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD852GE 7.7L inline-six, DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel standby for commercial, campus, and institutional facilities requiring current emissions and component independence.
250 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1381VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Tier 4 Final3-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD250-04FT4MP
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final mobile diesel for construction, planned outage support, and large-scale temporary power with clean emissions.
250 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1381VE six-cylinder engine, Stamford S4L1D-D41 alternator, DSE DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD275-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for large commercial, campus, and institutional facilities where value engineering and non-proprietary component access matter.
275 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD853GE 7.7L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD300-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for large commercial, campus, and industrial facilities where value engineering and non-proprietary component access matter.
300 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1351GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD300-02FT4
Open Basler DGC-2020 controller + Volvo Penta engine + Stamford alternator — Tier 4 Final, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel standby for large commercial and campus facilities requiring current emissions compliance and open-architecture components.
300 kW Tier 4 Final diesel standby generator. Volvo Penta TAD1373VE 12.8L inline-six, 208-600V output, with Basler DGC-2020 controller and SCR aftertreatment.
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel standby for large commercial, campus, and industrial facilities requiring current emissions and component independence.
300 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD1383VE 12.8L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.
Open Basler controller + Volvo Penta engine + Stamford alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final mobile diesel for construction, planned outage support, and large-scale temporary power with clean emissions.
300 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD1383VE six-cylinder engine, Stamford S4L1D-E41 alternator, DSE DCP7310 controller, 350-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD350-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for large commercial, industrial, and campus facilities where value engineering and non-proprietary component access matter.
350 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1352GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD400-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for industrial, campus, and data center facilities where value engineering and non-proprietary component access matter.
400 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1353GE 12.8L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD450-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
450 kW standby · Diesel · Liquid-cooled
450 kW diesel standby for industrial, campus, and data center facilities where value engineering and non-proprietary component access matter.
450 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1650GE 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD500-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for industrial, data center, and campus facilities where value engineering and non-proprietary component access matter.
500 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1641GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD550-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for industrial, data center, and campus facilities where value engineering and open-architecture components matter.
550 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1642GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD550-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
550 kW standby · Diesel · Liquid-cooled
550 kW Tier 4 Final diesel standby for industrial, data center, and campus facilities requiring current emissions and component independence.
550 kW standby / 500 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1682GE 16.12L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, three-phase 208-600V.
Open Basler controller + Volvo Penta engine + Leroy-Somer alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
550 kW standby · Diesel · Liquid-cooled
550 kW Tier 4 Final mobile diesel for industrial temporary power, planned outage support, and large-scale construction with clean emissions.
550 kW standby / 500 kW prime Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TWD1682GE six-cylinder engine, 572RSL6429 alternator, DSE DCP7310 controller, 550-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD600-01
Open Basler DGC-2020 controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW EPA Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1643GE 16.1L inline-six, 208-4160V output, available with medium-voltage option.
Tier 23-phaselarge-commercialhospital
Blue Star Power Systems
Blue Star VD600-03
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1644GE 16.1L inline-six with dual-stage turbo, DSE DCP7310 controller, 208-600V.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD600-04FT4
Open Basler controller + Volvo Penta engine + Stamford alternator — Tier 4 Final compliant, no proprietary lock-in. Serviceable by any qualified tech.
600 kW standby · Diesel · Liquid-cooled
600 kW Tier 4 Final diesel standby for industrial, data center, and campus facilities requiring current emissions and component independence.
600 kW standby / 570 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1683GE 16.12L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, three-phase 208-600V.
Open Basler controller + Volvo Penta engine + Leroy-Somer alternator — trailer-mounted, no proprietary lock-in. Serviceable by any qualified tech.
600 kW standby · Diesel · Liquid-cooled
600 kW Tier 4 Final mobile diesel for industrial temporary power, planned outage support, and large-scale construction with clean emissions.
600 kW standby / 570 kW prime Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TWD1683GE six-cylinder engine, 572RSL6431 alternator, DSE DCP7310 controller, 550-gallon integrated fuel tank.
Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems
Blue Star VD700-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. 700 kW class without OEM dealer dependency.
700 kW standby · Diesel · Liquid-cooled
700 kW diesel standby for industrial, data center, and mission-critical facilities where value engineering and non-proprietary components matter.
700 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1744GE 17.3L inline-six with Common Rail injection, DSE DCP7310 controller, 208-600V.
Tier 23-phaselarge-commercialhospital
Caterpillar
Cat 3512
1000 kW diesel with CAT 3512 V-12. Best resale value in class. ~200 US dealers with parts availability back decades.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for Tier III data centers, large hospitals, and industrial campuses with CAT fleet.
1000-1400 kVA diesel generator with Cat 3512 V-12 engine. 51.8L displacement, Woodward governor, continuous/prime/standby ratings.
3-phasecommercial-standbyindustrial
Caterpillar
Cat 3512B
1500 kW diesel with CAT 3512B V-12. Best resale -- retains 15-25% more than Cummins/MTU. Deepest parts network.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
1230-1500 kW diesel generator with Cat 3512B V-12 engine. EUI fuel system, EMCP 4.2B controller, mission-critical and standby ratings.
3-phasecommercial-standbymission-critical
Caterpillar
Cat 3516
1600 kW diesel with CAT 3516 V-16. Best resale -- retains 15-25% more than competitors. ~200 US dealer network.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW diesel standby for large data centers, hospitals, and industrial campuses with CAT fleet standardization.
1600 kW diesel generator with Cat 3516 turbocharged V-16 engine. Mission-critical platform for data centers, hospitals, and large industrial standby and prime power.
3-phasedata-centerhospital
Caterpillar
Cat 3516B
2000 kW diesel with CAT 3516B V-16. Best resale value in class. Paralleling for multi-MW. ~200 US dealers.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for Tier IV data centers, large hospitals, and campus-scale critical infrastructure.
2500 kW diesel with CAT 3516C V-16. EPA Tier 4 Final. Best resale in class. Paralleling for multi-MW arrays.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby for hyperscale data centers, campus microgrids, and emission-regulated industrial.
2500 kW diesel standby generator with Cat 3516C V-16 engine. The largest Cat genset platform for mission-critical data centers and industrial power.
Tier 23-phasedata-centerhospital-large
Caterpillar
Cat 3516E
3000 kW diesel with CAT 3516E V-16. Best resale value in class. Paralleling for multi-MW. ~200 US dealers.
3 MW standby · Diesel · Liquid-cooled
3000 kW diesel standby for hyperscale data centers, campus microgrids, and utility peak shaving.
Up to 3000 kW diesel generator with Cat 3516E V-16 engine. 78.1L displacement, Tier 2 equivalent, ATAAC aspiration for standby and mission-critical power.
Tier 23-phasecommercial-standbymission-critical
Caterpillar
Cat C15
500 kW diesel with CAT C15 ACERT inline-6. Best resale value in class. ~200 US dealers with deep parts inventory.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for hospitals, data centers, and large commercial with CAT fleet standardization.
500 kW diesel standby generator with Cat C15 ACERT engine. Large commercial standby for hospitals, high-rises, and municipal infrastructure.
Tier 23-phasehospitalhigh-rise
Caterpillar
Cat C175-16
3100 kW diesel with CAT C175-16 V-16. Medium-voltage capable (4160V/13.8kV). Best resale. Paralleling for multi-MW.
3.1 MW standby · Diesel · Liquid-cooled
3100 kW diesel standby for hyperscale data centers, campus microgrids, and mission-critical infrastructure.
2500-3100 kW diesel generator with Cat C175-16 SCAC V-16 engine. 84.7L displacement, Tier 2, mission-critical and standby power for data centers and large industrial facilities.
Tier 23-phasecommercial-standbymission-critical
Caterpillar
Cat C175-20
4000 kW diesel with CAT C175-20 V-20. CAT largest genset. Medium-voltage capable. Best resale in class.
4 MW standby · Diesel · Liquid-cooled
4000 kW diesel standby for hyperscale data centers, utility-scale backup, and campus microgrids.
Up to 4000 kW diesel generator with Cat C175-20 SCAC V-20 engine. 105.8L displacement, mission-critical and continuous duty power for large industrial and utility applications.
3-phasecommercial-standbymission-critical
Caterpillar
Cat C27
800 kW diesel with CAT C27 V-12. Best resale -- retains 15-25% more than competitors. Paralleling-ready.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
1500 kW diesel with CAT 3512C V-12. EPA Tier 4 Final. Best resale value in class. ~200 US dealers.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier III+ data centers, hospitals, and emission-sensitive industrial sites.
The Caterpillar 3512C is a 1500 kW standby diesel generator. 51.8L V12 ATAAC, 14.7:1 compression, EPA Tier 2. Fuel: 104.6 gal/hr at full load. Medium-voltage outputs to 13,800V for mission-critical applications.
Tier 23-phasedata-centerhospital-large
Caterpillar
Caterpillar C13
350 kW diesel with CAT C13 ACERT inline-6. Best resale -- retains 15-25% more than competitors. ~200 US dealers.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for hospitals, large commercial, and industrial with CAT fleet standardization.
The Caterpillar C13 ACERT is a 350 kW standby diesel generator with EPA Tier 3 certification. 12.5L inline-6 with MEUI injection. Fuel consumption 24.9 gal/hr at full load. Complete specs and service reference.
Tier 33-phasecommercial-standbyhospital-medium
Caterpillar
Caterpillar C18
600 kW diesel with CAT C18 ACERT inline-6. Best resale -- retains 15-25% more than Cummins/MTU. ~200 US dealers.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for large data centers, hospitals, and industrial plants with CAT fleet.
The Caterpillar C18 ACERT is a 600 kW standby diesel generator with EPA Tier 2 certification. 18.1L inline-6 with MEUI injection. Fuel: 42.7 gal/hr at full load. Supports 4160V medium-voltage for hospital and campus applications.
Tier 23-phasehospital-mediumcampus
Caterpillar
Caterpillar C7
200 kW diesel with CAT C7 ACERT inline-6. Best resale value in class. ~200 US dealers. Compact footprint.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for retail, telecom, and small commercial with CAT fleet standardization.
The Caterpillar C7.1 ACERT is a 200 kW standby diesel generator with EPA Tier 3 certification. 7.01L inline-6 with MEUI fuel injection. Compact standby power for small commercial and retail applications.
Tier 33-phasecommercial-standbyretail
Caterpillar
Caterpillar C9
250 kW diesel with CAT C9 ACERT inline-6. Best resale -- retains 15-25% more than competitors. ~200 US dealers.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for mid-size commercial, schools, and light-industrial with CAT fleet.
The Caterpillar C9 ACERT is a 250 kW standby diesel generator with EPA Tier 3 emissions certification. 8.8L inline-6 with MEUI fuel injection. Ideal for retail, telecom, and light-industrial standby applications.
Tier 33-phasecommercial-standbyretail
Cummins
Cummins C100 D6
100 kW diesel with full Cummins vertical integration. 100% load acceptance in 10 seconds. Single-source warranty.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for office complexes, hotels, and commercial buildings requiring fast load pickup.
100 kW EPA Tier 3 diesel standby generator with QSB5-G13 engine and PowerCommand 2.3 control. Sound-attenuated aluminum enclosure, UL 2200 listed, NFPA 110 Level 1 capable.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins C30 D5
30 kW diesel with full Cummins vertical integration -- engine, alternator, controls all in-house. One manufacturer warranty.
30 kW standby · Diesel · Liquid-cooled
30 kW diesel standby for international 50 Hz commercial sites, telecom, and small infrastructure.
30 kW diesel generator from Cummins' international D5 export series. 50 Hz model designed for markets outside North America. Compact liquid-cooled standby generator for commercial standby applications.
3-phasecommercial-standbyinternational-export
Cummins
Cummins C50 D5
50 kW diesel with full Cummins vertical integration -- engine, alternator, controls all in-house. One manufacturer warranty.
50 kW standby · Diesel · Liquid-cooled
50 kW diesel standby for international 50 Hz commercial, retail, and light-industrial applications.
50 kW diesel generator from Cummins' international D5 export series. 50 Hz model for markets outside North America. Liquid-cooled standby generator for commercial applications.
3-phasecommercial-standbyinternational-export
Cummins
Cummins C80 D6
80 kW diesel with full Cummins vertical integration. 100% load acceptance in 10 seconds. One throat to choke.
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby for commercial buildings, healthcare clinics, and municipal water systems.
80 kW EPA Tier 3 diesel standby generator with QSB5-G13 engine and PowerCommand 2.3 control. Sound-attenuated aluminum enclosure, liquid-cooled, rated for 50°C ambient operation.
Tier 33-phasecommercial-standbylight-industrial
Cummins
Cummins KTA38
887 kW diesel with legendary KTA38 engine. Full Cummins vertical integration. Parts availability back decades.
887 kW standby · Diesel · Liquid-cooled
887 kW diesel standby for large industrial plants, hospitals, and mission-critical infrastructure.
887 kW standby / 811 kW prime diesel generator at 50 Hz. KTA38-G5 37.8L V12 PT fuel injection. Legacy Cummins platform for industrial, hospital, campus, and mining standby applications.
3-phaseindustrialhospital-large
Cummins
Cummins KTA50
1340 kW diesel with legendary KTA50 engine. Full Cummins vertical integration. 10-15% below CAT 3512 class.
1.3 MW standby · Diesel · Liquid-cooled
1340 kW diesel standby for Tier III+ data centers, large hospitals, and heavy industrial plants.
1340 kW standby / 1200 kW prime diesel generator at 50 Hz. KTA50-GS8 50.3L V16 PT fuel injection, 2-pump 2-loop cooling. Legacy Cummins platform for data center, industrial, hospital, and mining standby applications.
3-phasedata-centerhospital-large
Cummins
Cummins QSB7 (C200 D6)
200 kW diesel with QSB7 engine. Full Cummins vertical integration. 100% load in 10 seconds. Best cold-weather start (-40F).
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, office complexes, and commercial buildings in any climate.
200 kW diesel commercial standby generator with Cummins QSB7 6.7L engine. The mid-range diesel workhorse for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Cummins
Cummins QSK19
550 kW diesel with QSK19 engine. Full Cummins vertical integration. Power Command controller. 10-15% below CAT.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for large data centers, hospitals, and heavy industrial plants.
550 kW standby / 500 kW prime diesel generator with QSK19-G4 19L inline-6 MCRS engine. EPA Tier 2, CTT HX83 turbocharging, 24V starting. Engine dimensions 1695 x 985 x 1723 mm, dry weight 1900 kg.
Tier 23-phasehospital-mediumcampus
Cummins
Cummins QSK23
800 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
800 kW standby / 727 kW prime diesel generator with QSK23-G3 23.1L inline-6 HPI-PT engine. Non-regulated, CTT HX82 turbocharging, 24V starting. Engine dimensions 2976 x 1656 x 1964 mm, dry weight 3245 kg.
Tier 23-phasehospital-largecampus
Cummins
Cummins QSK38
1160 kW diesel with QSK38 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.
1.2 MW standby · Diesel · Liquid-cooled
1160 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
1160 kW standby / 965 kW prime diesel generator with QSK38-G5 37.7L V12 MCRS engine. EPA Tier 2, 2P2L cooling, 24V starting. Engine dimensions 2081 x 1492 x 1860 mm, dry weight 4100 kg.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK50
1500 kW diesel with QSK50 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3512.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants.
1500 kW standby / 1365 kW prime diesel generator with QSK50-G4 50.3L V16 MCRS engine. EPA Tier 2 and TA Luft compliant, 2P2L cooling, 24V starting. Engine dimensions 4674 x 2468 x 3100 mm, dry weight 7429 kg.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK60
2000 kW diesel with QSK60 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3516.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for hyperscale data centers, large hospitals, and campus microgrids.
2000 kW diesel standby generator. The data center industry standard — V-16, 60.2L, Tier 2. Cummins' flagship for mission-critical power.
Tier 23-phasedata-centerhospital
Cummins
Cummins QSK78
2750 kW diesel with QSK78 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3516B.
2.8 MW standby · Diesel · Liquid-cooled
2750 kW diesel standby for hyperscale data centers, critical infrastructure, and utility peaking.
2750 kW standby / 2500 kW prime diesel generator with QSK78-G14 V18 engine. EPA Tier 4 Final, 78-liter displacement for mission-critical and data center power.
Tier 4 Final3-phasedata-centerhospital
Cummins
Cummins QSL9
300 kW diesel with QSL9 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, multi-building campuses, and industrial plants.
300 kW standby / 275 kW prime diesel generator with QSL9-G7 8.8L inline-6 Bosch HPCR engine. EPA Tier 3 / EU Stage IIIA compliant, Holset HX40 wastegated turbo, 24V starting. Engine dimensions 2157 x 1126 x 1562 mm, dry weight 940 kg.
500 kW diesel with QSX15 engine. Full Cummins vertical integration. Power Command controller. 10-15% below CAT.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for major hospitals, Tier III data centers, and large industrial facilities.
500 kW standby / 450 kW prime diesel generator with QSX15-G9 engine. 24-valve DOHC, 15-liter inline-6, EPA NSPS certified for commercial and industrial power.
3-phasecommercial-standbyindustrial
Doosan / Bobcat
Doosan G100
First Cummins-powered Doosan — Stamford alternator and Cummins F3.8 engine deliver premium-grade components at 15-30% below MQ Power/Airman pricing.
88 kW standby · Diesel · Liquid-cooled
Commercial construction sites, emergency standby for mid-size buildings, rental fleet 100 kVA class, and temporary power for events and film production.
80 kW prime diesel portable generator. Cummins F3.8-powered with 67 dBA operation, Stamford alternator, and dual-frequency switching.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G125
Cummins QSB5 with no DPF required for Tier 4 Final — simpler maintenance than DPF-equipped competitors. 24.9-hour full-load runtime from 176.5-gallon tank.
110 kW standby · Diesel · Liquid-cooled
Commercial construction, mid-size building emergency standby, rental fleet 125 kVA class, and temporary power for large events or commercial renovations.
100 kW prime diesel portable generator. Cummins QSB5-G11-powered with 68 dBA operation, 176.5-gallon tank, and 24.9-hour runtime.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G150
23% more power than the G125 in the exact same chassis and footprint. Cummins QSB5 with no DPF — bridges the gap before stepping up to the larger DualBox G190.
135 kW standby · Diesel · Liquid-cooled
Commercial construction needing 100-150 kW, rental fleet gap-filler between 125 and 190 kVA classes, and temporary power for mid-size commercial buildings.
123 kW prime diesel portable generator. Cummins QSB5-G12-powered with 68 dBA operation and shared G125 chassis.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G190
First DualBox enclosure model — separated powertrain and cooling compartments for improved thermal management. 368-gallon tank delivers 31.7-hour runtime at Cummins pricing advantage.
160 kW standby · Diesel · Liquid-cooled
Large commercial construction, data center temporary power, utility emergency standby, and rental fleet heavy-duty class.
145 kW prime diesel portable generator. Cummins QSB7-G8-powered with 69 dBA operation, DualBox enclosure, and 368-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G240
Higher-output QSB7 variant in the same DualBox chassis as the G190 — 30% more power without a larger footprint. 27-hour runtime from 368-gallon tank at full load.
200 kW standby · Diesel · Liquid-cooled
Large commercial construction, hospital and data center temporary power, utility emergency standby, and rental fleet heavy-duty class.
190 kW prime diesel portable generator. Cummins QSB7-G9-powered with 69 dBA operation, 368-gallon tank, and 27-hour runtime.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G25
Rental-grade CoolBox enclosure at 15-30% below MQ Power/Airman pricing. Doosan D18 engine is simple and reliable with low maintenance costs.
22 kW standby · Diesel · Liquid-cooled
Small construction sites, single-trade contractors, residential renovation backup, and rental fleet entry-level units.
20 kW prime diesel portable generator. Doosan D18-powered with 63 dBA operation and 25-hour runtime at full load.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G325
Cummins QSL9 8.9L in the large-frame class at 15-30% below Atlas Copco and MQ Power. 480-gallon tank and 1,000A main breaker for sustained heavy loads.
290 kW standby · Diesel · Liquid-cooled
Large commercial construction, data center temporary power, utility emergency standby, hospital backup, and rental fleet large-frame class.
260 kW prime diesel portable generator. Cummins QSL9-G9-powered with 480-gallon tank and 1,000A main breaker.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G40
110-gallon tank delivers 24+ hour runtime at full load — class-leading for 40 kVA portables. CoolBox enclosure at 64 dBA matches WhisperWatt pricing 15-30% lower.
34 kW standby · Diesel · Liquid-cooled
Multi-day construction sites, commercial renovation backup, rental fleet mid-range units, and temporary event power.
30 kW standby diesel portable generator. Doosan D24-powered with 64 dBA operation, CoolBox enclosure, and 110-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G400
Current-generation Tier 4 Final replacement for the legacy G450. Cummins QSG12 with variable-speed cooling fan and 470-gallon tank at value-tier pricing.
374 kW standby · Diesel · Liquid-cooled
Large commercial construction, data center temporary power, utility emergency standby, industrial facilities, and rental fleet large-frame class.
340 kW prime diesel portable generator. Cummins QSG12-powered with 11.8-liter engine and 470-gallon tank.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G450
Legacy Tier 2 with no DPF, no SCR, no DEF — the simplest large-frame maintenance in the lineup. Cummins QSX15 proven reliability at value-tier pricing.
400 kW standby · Diesel · Liquid-cooled
Large construction sites in Tier 2-permissible jurisdictions, mining operations, industrial standby, and rental fleet legacy units still in active service.
375 kW prime diesel portable generator. Cummins QSX15-powered large-frame unit with 574-gallon tank. Legacy Tier 2 model.
Tier 23-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G50
37-hour runtime on 110-gallon tank — longest in the 50 kVA portable class. Same D24 engine and chassis as G40, giving fleet operators parts commonality.
42 kW standby · Diesel · Liquid-cooled
Multi-day construction sites needing more than 30 kW, commercial temporary power, rental fleet mid-range units, and dual-frequency international projects.
38 kW prime diesel portable generator. Doosan D24-powered with 64 dBA operation, 110-gallon tank, and 37.2-hour runtime.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G570
Flagship G-Series — Cummins X15 delivering 500 kW standby in a sound-attenuated enclosure at 15-30% below premium competitors. 656-gallon tank for extended runtime.
500 kW standby · Diesel · Liquid-cooled
Major commercial construction, data center temporary power, utility emergency standby, hospital backup, and large industrial facility temporary power.
456 kW prime diesel portable generator. Cummins X15-powered flagship with 500 kW standby and sound-attenuated enclosure.
Tier 4 Final3-phaseconstructionrental-fleet
Doosan / Bobcat
Doosan G70
Largest Doosan-engine model — D34 turbo delivers 56 kW at 64 dBA, quietest in the 70 kVA mid-range class. DOC+SCR aftertreatment, no DPF to manage.
60 kW standby · Diesel · Liquid-cooled
Mid-range construction sites, commercial temporary power, rental fleet workhorse units, and mixed single/three-phase jobsite loads.
56 kW prime diesel portable generator. Doosan D34-powered with 64 dBA operation, Marelli alternator, and dual-frequency switching.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK125F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
110 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
125 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK125FP
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
110 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
125 kVA parallel-capable portable diesel generator with SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK14F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
12 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
14 kVA portable diesel generator with SimulPhase technology. Built in Japan by Shindaiwa/Yamabiko.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK15F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
13 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
15 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK15FL
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
13 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
15 kVA portable diesel generator with large fuel tank and SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK180F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
158 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
180 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK180FP
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
158 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
180 kVA parallel-capable portable diesel generator with SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK20FS
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
22 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
20 kW single-phase portable diesel generator with SimulPhase technology.
Tier 4 FinalSingle-phaseconstructionrental-fleet
Echo
Echo DGK25F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
22 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
25 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK36FS
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
40 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
36 kW single-phase portable diesel generator with SimulPhase technology.
Tier 4 FinalSingle-phaseconstructionrental-fleet
Echo
Echo DGK400F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
352 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
400 kVA portable diesel generator. Flagship Echo/Shindaiwa unit with SimulPhase technology.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK45F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
39 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
45 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK70F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
60 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
70 kVA portable diesel generator with SimulPhase technology. Built in Japan.
Tier 4 Final3-phaseconstructionrental-fleet
Echo
Echo DGK7F
Patented SimulPhase — simultaneous single and three-phase output from one unit, eliminating step-down transformers on mixed-load sites.
6 kW standby · Diesel · Liquid-cooled
Mixed-load construction sites where SimulPhase eliminates transformer cost, and rental fleets discovering Shindaiwa heritage.
7 kVA portable diesel generator with SimulPhase technology. Built in Japan by Shindaiwa/Yamabiko.
Tier 4 FinalSingle-phaseconstructionrental-fleet
Generac
Generac SD010
10 kW industrial diesel at 10-15% below Kohler equivalent. Perkins engine reliability. Digital H controller with NFPA 110 Level I/II.
10 kW standby · Diesel · Liquid-cooled
10 kW diesel standby for small commercial, retail, and municipal pump stations.
10 kW industrial diesel standby generator. Perkins 2.2L turbocharged inline-4, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
130 kW industrial diesel with Iveco/FPT engine. 10-15% below Kohler pricing. Digital controller with paralleling capability.
130 kW standby · Diesel · Liquid-cooled
130 kW diesel standby for mid-size commercial, light manufacturing, and healthcare clinics.
130 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD150
150 kW industrial diesel with 10,000+ dealer support network. 10-15% below Kohler pricing. NFPA 110 compliant.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hotels, warehouses, and commercial office buildings.
150 kW industrial diesel standby generator. Iveco/FPT 6.7L turbocharged-aftercooled inline-6 with electronic injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD1500
1500 kW industrial diesel with Mitsubishi engine. Cost-effective alternative to CAT 3512 class. Multi-MW paralleling.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants.
175 kW diesel standby for large retail, assisted living, and mid-size industrial facilities.
175 kW industrial diesel standby generator. Generac 6.7L turbocharged-aftercooled inline-6 with electronic injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD200
200 kW industrial diesel with Iveco 6.7L engine. 10-15% cost advantage over Kohler. Paralleling-ready controller.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, data centers, and large commercial complexes.
250 kW industrial diesel at 10-15% below Kohler equivalent. Proven Iveco/FPT engine. Largest US dealer network.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, manufacturing plants, and high-rise buildings.
250 kW industrial diesel standby generator. Iveco/FPT 8.7L turbocharged-aftercooled inline-6 with common rail injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD2500/MD2500
2500 kW diesel in SD/MD platform with Baudouin engine. Cost-competitive with CAT 3516B at lower acquisition cost.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby for Tier IV data centers, critical infrastructure, and utility peaking.
2500 kW diesel industrial standby generator. Baudouin 65.6L V12 turbocharged/aftercooled, EPA Tier 2 Certified Stationary Emergency. Data Center Ready.
Tier 23-phasecommercial-standbyindustrial
Generac
Generac SD275
275 kW industrial diesel. 10-15% below Kohler at comparable kW. Digital control with paralleling and load management.
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby for large commercial campuses, water treatment, and healthcare facilities.
275 kW industrial diesel standby generator. Iveco/FPT 10.3L turbocharged-aftercooled inline-6 with common rail injection, EPA Certified Stationary Emergency, Digital H control with NFPA 110 Level I/II.
3-phasecommercial-standbylight-industrial
Generac
Generac SD300
300 kW industrial diesel with Iveco engine. 10-15% cost advantage vs Kohler. NFPA 110 compliant, paralleling-ready.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, multi-building campuses, and industrial plants.
600 kW industrial diesel with Perkins engine. 10-15% below Kohler equivalent. Paralleling-ready for multi-unit systems.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for large data centers, hospitals, and heavy industrial facilities.
600 kW standby diesel generator with Perkins 18.1L inline-6 engine. EPA certified stationary emergency. Three-phase 120/208V to 346/600V. UL2200 listed.
3-phasecommercial-standbyindustrial-standby
Generac
Generac SD750
750 kW industrial diesel. Competitive pricing vs Kohler/Cummins. Paralleling-ready for campus-scale backup.
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
750 kW standby diesel generator with Perkins 18.1L inline-6 engine. EPA certified stationary emergency. Three-phase 120/208V to 346/600V. UL2200 listed.
3-phasecommercial-standbyindustrial-standby
Gillette
Gillette SPD-1000
Factory-direct at 15-30% below major brands. Perkins engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial buildings, telecom sites, pump stations, and light industrial facilities.
100 kW stationary diesel standby generator with Perkins 1104D-E44TAG2 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPD-1500
Factory-direct at 15-30% below major brands. Perkins 7.0L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
150 kW standby · Diesel · Liquid-cooled
150 kW diesel standby for hospitals, hotels, commercial buildings, and municipal infrastructure.
150 kW stationary diesel standby generator with Perkins 1106D-E70TAG4 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPD-2000
Factory-direct at 15-30% below major brands. Perkins 7.0L I6 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
200 kW standby · Diesel · Liquid-cooled
200 kW diesel standby for hospitals, hotels, water treatment, and mid-size commercial or municipal facilities.
200 kW stationary diesel standby generator with Perkins 1106D-E70TAG5 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPD-300
Factory-direct at 15-30% below major brands. Perkins engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
30 kW standby · Diesel · Liquid-cooled
30 kW diesel standby for cost-conscious commercial, telecom shelters, and small municipal pump stations.
30 kW stationary diesel standby generator with Perkins 404D-22TAG engine. Made-in-USA commercial diesel unit with Stamford alternator and DSE 7420 MKII controller.
Tier 4 Interim3-phasecommercialtelecom
Gillette
Gillette SPD-600
Factory-direct at 15-30% below major brands. Perkins engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for commercial buildings, telecom sites, retail stores, and pump stations.
60 kW stationary diesel standby generator with Perkins 1104D-E44TG1 engine. Made-in-USA with Stamford UCI224F alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPHD-9000
Factory-direct at 15-30% below major brands. Hyundai 21.9L V12 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
900 kW standby · Diesel · Liquid-cooled
900 kW diesel standby for data centers, hospitals, industrial campuses, and large-scale critical infrastructure.
900 kW stationary diesel standby generator with Hyundai DP222CCS V12 engine. Made-in-USA with Stamford S6DD311 alternator, shunt excitation, and DSE 7420 MKII controller.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPJD-1000
Factory-direct at 15-30% below major brands. John Deere 4045 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
100 kW standby · Diesel · Liquid-cooled
100 kW diesel standby for commercial, telecom, pump stations, and municipal buyers. Buy American compliant.
100 kW stationary diesel standby generator with John Deere 4045HF285 engine. Made-in-USA with Stamford UCI274D alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPJD-1550
Factory-direct at 15-30% below major brands. John Deere 6068 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
155 kW standby · Diesel · Liquid-cooled
155 kW diesel standby for hospitals, hotels, commercial buildings, and municipal infrastructure. Buy American compliant.
155 kW stationary diesel standby generator with John Deere 6068HF285 engine. Made-in-USA with Stamford UCI274G alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPJD-2100
Factory-direct at 15-30% below major brands. John Deere 6068 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
210 kW standby · Diesel · Liquid-cooled
210 kW diesel standby for hospitals, hotels, water treatment, and commercial facilities. Buy American compliant.
210 kW stationary diesel standby generator with John Deere 6068HF485 engine. Made-in-USA with Stamford UCID274J alternator and DSE 7420 MKII controller.
Tier 33-phasecommercialhospital
Gillette
Gillette SPJD-600
Factory-direct at 15-30% below major brands. John Deere engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
60 kW standby · Diesel · Liquid-cooled
60 kW diesel standby for cost-conscious commercial, telecom, and municipal buyers. Buy American compliant.
60 kW stationary diesel standby generator with John Deere engine. Made-in-USA commercial diesel unit with DSE controller and Stamford or Marathon alternator.
Tier 33-phasecommercialtelecom
Gillette
Gillette SPMI-1.5M
Factory-direct megawatt-class diesel at 15-30% below major brands. Mitsubishi S16R V16 engine + DSE controller — no proprietary lock-in.
1.5 MW standby · Diesel · Liquid-cooled
1,500 kW (1.5 MW) diesel standby for data centers, hospitals, industrial campuses, and municipal emergency power.
1,500 kW stationary diesel standby generator with Mitsubishi S16R V16 engine. 65.37L displacement, Stamford AVK S7L1D alternator, PMG excitation. Made in USA.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPMI-1M
Factory-direct megawatt-class diesel at 15-30% below major brands. Mitsubishi S12H engine + DSE controller — no proprietary lock-in.
1 MW standby · Diesel · Liquid-cooled
1,000 kW (1 MW) diesel standby for data centers, hospitals, industrial campuses, and utility-scale backup.
1,000 kW stationary diesel standby generator with Mitsubishi S12H engine. Made-in-USA with Stamford AVK S6D alternator, PMG excitation, and DSE 7420 MKII controller.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPMI-2M
Factory-direct 2 MW diesel at 15-30% below major brands. Mitsubishi S16R V16 — Gillette's largest unit. No proprietary lock-in.
2 MW standby · Diesel · Liquid-cooled
2,000 kW (2 MW) diesel standby for hyperscale data centers, hospitals, industrial campuses, and utility-grade backup.
2,000 kW stationary diesel standby generator with Mitsubishi S16R V16 engine. 65.37L displacement, Stamford AVK S7L1DG alternator, PMG excitation. Gillette's largest unit.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPMI-8000
Factory-direct at 15-30% below major brands. Mitsubishi S12A2 engine + DSE controller — no proprietary lock-in. 3-7 day lead times.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for data centers, hospitals, industrial campuses, and large-scale critical infrastructure.
800 kW stationary diesel standby generator with Mitsubishi S12A2 engine. Made-in-USA with Stamford AVK HCI634 alternator, PMG excitation, and DSE 7420 MKII controller.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPVD-2500
Factory-direct at 15-30% below major brands. Volvo Penta 7.7L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, hotels, data centers, and mid-size commercial or industrial facilities.
250 kW stationary diesel standby generator with Volvo Penta TAD852GE 7.7L engine. Stamford S4L1D alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-3000
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, hotels, data centers, and large commercial or industrial facilities.
300 kW stationary diesel standby generator with Volvo Penta TAD1351GE 12.8L engine. Stamford S4L1D alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-3500
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
350 kW standby · Diesel · Liquid-cooled
350 kW diesel standby for hospitals, data centers, hotels, and large commercial or campus facilities.
350 kW stationary diesel standby generator with Volvo Penta TAD1352GE 12.8L engine. Stamford S4L1DF alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-4000
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
400 kW standby · Diesel · Liquid-cooled
400 kW diesel standby for hospitals, data centers, hotels, and large commercial or campus facilities.
400 kW stationary diesel standby generator with Volvo Penta TAD1353GE 12.8L engine. Stamford S4L1DG alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital
Gillette
Gillette SPVD-5000
Factory-direct at 15-30% below major brands. Volvo Penta 16.1L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for data centers, hospitals, industrial campuses, and large municipal facilities.
500 kW stationary diesel standby generator with Volvo Penta TAD1641GE 16.1L engine. Stamford HCI534 alternator, Basler DGC-2020 controller. Made in USA.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPVD-5500
Factory-direct at 15-30% below major brands. Volvo Penta 16.1L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for data centers, hospitals, industrial campuses, and large municipal infrastructure.
550 kW stationary diesel standby generator with Volvo Penta TAD1642GE 16.1L engine. Stamford HCI534F alternator, Basler DGC-2020 controller. Made in USA.
Tier 23-phasedata-centerhospital
Gillette
Gillette SPVD-6000
Factory-direct at 15-30% below major brands. Volvo Penta 16.1L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for data centers, hospitals, industrial campuses, and large-scale commercial emergency backup.
Factory-direct at 15-30% below major brands. Volvo Penta 17.26L engine + Basler controller — Gillette's largest Volvo unit. No lock-in.
700 kW standby · Diesel · Liquid-cooled
700 kW diesel standby for data centers, hospitals, industrial campuses, and large-scale municipal or commercial facilities.
700 kW stationary diesel standby generator with Volvo Penta TWD1744GE 17.26L engine. Stamford S6DC311 alternator, Basler DGC-2020 controller. Gillette's largest Volvo unit.
Tier 23-phasedata-centerhospital
Gillette
Gillette T4D-1000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta engine + Basler controller — EPA/CARB compliant, no lock-in.
100 kW standby · Diesel · Liquid-cooled
100 kW Tier 4 Final diesel for air-quality-restricted sites, prime power, and commercial standby in CARB jurisdictions.
100 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD581VE 5.13L engine. SCR aftertreatment, DEF system, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-1500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 7.7L engine + Basler controller — EPA/CARB compliant, no lock-in.
150 kW standby · Diesel · Liquid-cooled
150 kW Tier 4 Final diesel for air-quality-restricted sites, hospitals, and prime power in CARB jurisdictions.
150 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD881VE 7.7L engine. SCR aftertreatment, DEF system, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-2000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 10.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
200 kW standby · Diesel · Liquid-cooled
200 kW Tier 4 Final diesel for hospitals, municipal sites, construction, and prime power in CARB jurisdictions.
200 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1180VE 10.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-2500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel for hospitals, municipal sites, and prime power in air-quality-restricted CARB jurisdictions.
250 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1381VE 12.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-3000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
300 kW standby · Diesel · Liquid-cooled
300 kW Tier 4 Final diesel for hospitals, municipal infrastructure, and prime power in CARB jurisdictions.
300 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1383VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-3500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
350 kW standby · Diesel · Liquid-cooled
350 kW Tier 4 Final diesel for hospitals, data centers, municipal sites, and prime power in CARB jurisdictions.
350 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1385VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-6000
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 16.1L engine — Gillette's largest T4F unit. EPA/CARB compliant.
600 kW standby · Diesel · Liquid-cooled
600 kW Tier 4 Final diesel for data centers, hospitals, industrial prime power, and sites in CARB jurisdictions.
600 kW standby / 570 kW prime Tier 4 Final diesel generator with Volvo Penta TWD1683GE 16.1L engine. H2O-to-air aftercooled, SCR+DEF. Gillette's largest T4F unit.
Tier 4 Final3-phasedata-centerhospital
Hipower Systems
Hipower HFW-100
FPT N67 inline-6 diesel at the 100 kW class — EPA Tier 4 Final certified, US-built, with the parts depth of a CNH Industrial engine ecosystem.
100 kW standby · Diesel · Liquid-cooled
Commercial standby power for office buildings, supermarkets, urgent care centers, and small data closets needing 100 kW with California emissions compliance.
100 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT N67 inline-6 diesel at 130 kW — EPA Tier 4 Final, US-built in Kansas, with three-phase and single-phase availability for flexible commercial standby applications.
130 kW standby · Diesel · Liquid-cooled
Industrial and commercial standby for office campuses, food processing, and distribution centers requiring 130 kW with California emissions compliance.
130 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT N67 at its 160 kW apex — EPA Tier 4 Final, single- and three-phase, US-built for demanding commercial and industrial standby in California-regulated environments.
160 kW standby · Diesel · Liquid-cooled
Industrial standby for mid-size manufacturing, multi-tenant office, and healthcare facilities requiring 160 kW with EPA Tier 4 Final certification.
160 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT C87 inline-6 steps up displacement to 8.7L at 180 kW — EPA Tier 4 Final, US-built, with the thermal headroom to handle demanding industrial standby loads.
180 kW standby · Diesel · Liquid-cooled
Industrial standby for manufacturing facilities, large office buildings, and data center support requiring 180 kW three-phase with full California emissions compliance.
180 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
200 kW on the FPT C87 8.7L inline-6 — EPA Tier 4 Final, US-built in Kansas, with Hipower's complete enclosure, controls, and fuel system integration for simplified permit submittals.
200 kW standby · Diesel · Liquid-cooled
Industrial standby and mission-critical backup for data centers, hospitals, and large commercial buildings requiring 200 kW with California emissions compliance.
200 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT C87 inline-6 at 230 kW — EPA Tier 4 Final, US-built, bridging the gap between 200 kW and 250 kW for applications that benefit from the additional headroom.
230 kW standby · Diesel · Liquid-cooled
Industrial standby for large manufacturing, multi-story commercial buildings, and critical infrastructure needing 230 kW three-phase with California emissions compliance.
230 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
250 kW at the top of the FPT C87 range — EPA Tier 4 Final, US-built, with Stamford S4L1D-family alternator and comprehensive enclosure options for demanding industrial and mission-critical standby.
250 kW standby · Diesel · Liquid-cooled
Mission-critical and industrial standby for data centers, hospitals, and large commercial complexes requiring 250 kW three-phase with California emissions compliance.
250 kW standby diesel generator with FPT C87 8.7L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT C13 12.9L inline-6 steps up to 300 kW with ample displacement headroom — EPA Tier 4 Final, US-built, for mission-critical and large industrial standby in California-regulated environments.
300 kW standby · Diesel · Liquid-cooled
Mission-critical standby for data centers, hospital campuses, large industrial facilities, and multi-building commercial complexes requiring 300 kW three-phase with California emissions compliance.
300 kW standby diesel generator with FPT C13 12.9L inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT Industrial-powered stationary diesel at commercial price points — US-built in Olathe, Kansas with EPA Tier 4 Final certification for California compliance.
60 kW standby · Diesel · Liquid-cooled
Commercial standby backup for retail, light industrial, and small office buildings requiring 60 kW with strict emissions compliance.
60 kW standby diesel generator with FPT N45 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
FPT N45-powered 90 kW standby diesel with EPA Tier 4 Final compliance — filling the gap between 80 kW and 100 kW for applications that need head room without stepping up to a larger engine family.
90 kW standby · Diesel · Liquid-cooled
Commercial standby for mid-size retail, urgent care clinics, and light manufacturing needing 90 kW with emissions compliance for California permitting.
90 kW standby diesel generator with FPT N45 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.
105 kW diesel standby generator. John Deere 4045HF285 family engine, Stamford UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbylight-commercial
Hipower Systems
Hipower HJW-130
129 kW standby · Diesel · Liquid-cooled
129 kW diesel standby generator. John Deere 4045HF285-147 engine, Stamford UCI 274 F alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-155
155 kW standby · Diesel · Liquid-cooled
155 kW diesel standby generator. John Deere 6068HF285 family engine, Stamford UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-205
205 kW standby · Diesel · Liquid-cooled
205 kW diesel standby generator. John Deere 6068 or 6081 family engine, Stamford UCDI 274 or UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-225
225 kW standby · Diesel · Liquid-cooled
225 kW diesel standby generator. John Deere 6090HF484-258 engine, Stamford HCI 444 D alternator. EPA Tier 3. US manufactured in Lenexa, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-275
275 kW standby · Diesel · Liquid-cooled
275 kW diesel standby generator. John Deere 6090HF484-315 engine, Stamford HCI 444 E alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-305
305 kW standby · Diesel · Liquid-cooled
305 kW diesel standby generator. John Deere 6090HF484 family engine, Stamford HCI 444 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-355
355 kW standby · Diesel · Liquid-cooled
355 kW diesel standby generator. John Deere 6090HF484 family engine, Stamford HCI 444 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-410
410 kW standby · Diesel · Liquid-cooled
410 kW diesel standby generator. John Deere 6090HF484 family engine, Stamford HCI 444 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems
Hipower HJW-55
55 kW standby · Diesel · Liquid-cooled
55 kW diesel standby generator. John Deere 4045TF280-63 engine, Stamford UCI 224 alternator. EPA Tier 3. US manufactured in Lenexa, Kansas.
Tier 33-phasecommercial-standbylight-commercial
Hipower Systems
Hipower HJW-65
65 kW standby · Diesel · Liquid-cooled
65 kW diesel standby generator. John Deere 4045HF280-74 engine, Stamford UCI 224 alternator. EPA Tier 3. US manufactured in Lenexa, Kansas.
Tier 33-phasecommercial-standbylight-commercial
Hipower Systems
Hipower HJW-85
80 kW standby · Diesel · Liquid-cooled
80 kW diesel standby generator. John Deere 4045HF285-94 engine, Stamford UCI 274 D alternator. EPA Tier 3. US manufactured in Olathe, Kansas.
Tier 33-phasecommercial-standbylight-commercial
Hipower Systems
Hipower HMW-1020
First MW-class unit in the HMW lineup — MTU 16V2000 32L 16-cylinder with 30,000-hour TBO. Standard for hyperscale data center 1 MW bus design.
1.0 MW standby · Diesel · Liquid-cooled
1 MW+ critical standby for hyperscale data center 1 MW bus rows, large hospital main plants, and mission-critical industrial utility in NFPA 110 Level 1 applications.
1020 kW MTU 2000-series diesel generator. Exceeds 1 MW standby. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1205
MTU 16V2000 at 1,205 kW — top of the 2000 series before entering the 4000 series. Maximum output for a single 16V2000 unit with 30,000-hour TBO.
1.2 MW standby · Diesel · Liquid-cooled
1.2 MW single-unit critical standby for hyperscale data center rows, large hospital main plants, and transmission-level utility backup.
1205 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1550
MTU 4000 series — the industrial benchmark for 1.5 MW+ standby. 52L 12-cylinder V with 30,000-hour TBO. Used in defense, hyperscale, and utility generation.
1.6 MW standby · Diesel · Liquid-cooled
1.5 MW critical standby for hyperscale data centers, major hospital campuses, military installations, and electric utility backup in NFPA 110 Level 1 applications.
1550 kW MTU 4000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1730
MTU 12V4000 at 1.7 MW — maximum output for the 12-cylinder 4000 series. 30,000-hour TBO at 1.7 MW single-unit standby.
1.7 MW standby · Diesel · Liquid-cooled
1.7 MW critical standby for hyperscale data centers, military bases, and large hospital campuses requiring NFPA 110 Level 1 with CARB compliance.
1730 kW MTU 4000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1975
MTU 16V4000 near-2 MW — 68L 16-cylinder V with 30,000-hour TBO. The largest single-unit generator class deployed at hyperscale cloud data centers.
2.0 MW standby · Diesel · Liquid-cooled
Near-2 MW critical standby for hyperscale data centers, transmission substations, military bases, and large campus essential systems.
1975 kW MTU 4000-series diesel generator. Near-2 MW single unit. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-2230
The largest HMW model — MTU 16V4000 at 2.2 MW. 68L 16-cylinder V, 30,000-hour TBO. The maximum single-unit diesel generator for hyperscale data centers.
2.2 MW standby · Diesel · Liquid-cooled
2+ MW critical standby for hyperscale data centers, utility substations, military base power, and large campus essential electrical systems.
2230 kW MTU 4000-series diesel generator. 2.2 MW single unit. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-270
MTU 1600-series engine with 30,000-hour TBO — the benchmark for mission-critical data center and hospital standby applications.
270 kW standby · Diesel · Liquid-cooled
Tier I data centers, hospital campuses, and utility substations requiring NFPA 110 Level 1 life-safety compliance.
270 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-310
MTU 1600-series 10-cylinder engine with 30,000-hour TBO — mission-critical standby at the 300 kW class without the Big 4 price premium.
310 kW standby · Diesel · Liquid-cooled
Tier I data centers, hospital critical branches, and municipal emergency operations centers needing NFPA 110 Level 1 compliance.
310 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-370
MTU 1600-series 12-cylinder engine — more torque and transient response than 10-cylinder alternatives at the same power class.
370 kW standby · Diesel · Liquid-cooled
Data centers, hospitals, and utilities requiring NFPA 110 Level 1 in the 350-400 kW range with seismic and CARB compliance.
370 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-405
MTU 12V1600 12-cylinder engine at the 400 kW class — the highest TBO in its power range, preferred by NorCal data center and hospital procurement teams.
405 kW standby · Diesel · Liquid-cooled
400 kW-class critical standby for Tier I data centers, hospital essential systems, and utility substations in CARB-regulated regions.
405 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-510
MTU 16V1600 — 16-cylinder V-engine at 500+ kW with the same 30,000-hour TBO as smaller HMW models. Caterpillar 3512 competitor at lower lifecycle cost.
510 kW standby · Diesel · Liquid-cooled
500 kW-class mission-critical standby for large data centers, trauma centers, and industrial utility applications requiring NFPA 110 Level 1.
510 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-615
MTU 16V1600 at 600+ kW — top of the 1600 series with 30,000-hour TBO. The benchmark for single-unit 600 kW critical standby.
615 kW standby · Diesel · Liquid-cooled
600 kW-class single-unit critical standby for hyperscale data center pods, large hospital campuses, and utility generation in seismic and CARB regions.
615 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-810
MTU 2000 series enters at 810 kW — 24L 12-cylinder V-engine with 30,000-hour TBO. The engine choice of Tier I hyperscale data centers globally.
810 kW standby · Diesel · Liquid-cooled
800 kW-class critical standby for hyperscale data center rows, large hospital campuses, and electric utility installations requiring NFPA 110 Level 1 in seismic and CARB regions.
810 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-915
MTU 12V2000 at near-MW output — 30,000-hour TBO, single-unit 900 kW standby with NFPA 110 Level 1, seismic, and CARB compliance in one package.
915 kW standby · Diesel · Liquid-cooled
Near-MW critical standby for hyperscale data center rows, large hospital campuses, and industrial utilities needing single-unit 900 kW coverage.
915 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 4 Final3-phaseindustrial-standbydata-center
Hipower Systems
Hipower HRJW-115
92 kW standby · Diesel · Liquid-cooled
92 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaserental-fleetconstruction
Hipower Systems
Hipower HRJW-125
100 kW standby · Diesel · Liquid-cooled
100 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaserental-fleetconstruction
Hipower Systems
Hipower HRJW-145
116 kW standby · Diesel · Liquid-cooled
116 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaserental-fleetconstruction
Hipower Systems
Hipower HRJW-190
US-manufactured mobile generators with John Deere inline-6 power — rental-ready with lockable enclosure, integrated tank, and hours meter.
166 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites needing towable 150-170 kW temporary power.
166 kW rental-ready trailer-mounted diesel generator. John Deere 6068HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaseconstructionrental-fleet
Hipower Systems
Hipower HRJW-240
US-manufactured 200+ kW mobile generator with John Deere inline-6 power — rental-ready for construction and event applications.
211 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites needing towable 200-215 kW temporary power.
211 kW rental-ready trailer-mounted diesel generator. John Deere 6068-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaseconstructionrental-fleet
Hipower Systems
Hipower HRJW-310
248 kW standby · Diesel · Liquid-cooled
248 kW rental-ready trailer-mounted diesel generator. John Deere 6090HF484-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaserental-fleetconstruction
Hipower Systems
Hipower HRJW-325
The largest John Deere-powered mobile generator in the Hipower HRJW lineup — US-manufactured, rental-ready, Stamford alternator.
286 kW standby · Diesel · Liquid-cooled
Rental fleets and construction sites needing towable 275-290 kW temporary power.
286 kW rental-ready trailer-mounted diesel generator. John Deere 6090HF484-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaseconstructionrental-fleet
Hipower Systems
Hipower HRJW-75
60 kW standby · Diesel · Liquid-cooled
60 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaserental-fleetconstruction
Hipower Systems
Hipower HRJW-95
76 kW standby · Diesel · Liquid-cooled
76 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.
3-phaserental-fleetconstruction
Hipower Systems
Hipower HRMW-1150
1150 kW on a towable trailer — MTU 16V2000 power with the mobility for data center commissioning, disaster recovery, and utility substation backup.
1.1 MW standby · Diesel · Liquid-cooled
Temporary 1 MW+ power for data center commissioning, disaster recovery bridge power, utility substation backup, and large construction projects requiring tow-in generation.
1150 kW trailer-mounted MTU diesel generator. Rental-ready for data center commissioning and disaster recovery. Built in Olathe, Kansas.
Tier 4 Final3-phaserental-fleetdata-center
Kohler
Kohler 1250REOZMD
1280 kW diesel standby -- Mitsubishi S12R-Y2PTAW-1, sub-3% THD. Decision-Maker controller for load management and paralleling.
1.3 MW standby · Diesel · Liquid-cooled
1280 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
1280 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 1250ROZMC
1120 kW diesel standby -- Mitsubishi S12R V12 turbo, sub-3% THD. Decision-Maker controller for load management and paralleling.
1.1 MW standby · Diesel · Liquid-cooled
1120 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
1120 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
3-phasedata-centerhealthcare
Kohler
Kohler 125REOZJ4
THD below 3% at 130 kW -- the healthcare and commercial default. John Deere 6068HG550 with Decision-Maker controller.
130 kW standby · Diesel · Liquid-cooled
130 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
130 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 145REOZT4
130 kW mobile diesel trailer -- Tier 4 John Deere 6068HG550. DOT-towable for large temporary power and emergency deployment.
130 kW standby · Diesel · Liquid-cooled
130 kW mobile standby for large construction projects, event power, emergency response, and planned outage bridge power.
130 kW diesel mobile trailer Tier 4 Final commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 150REOZJ4
THD below 3% at 150 kW -- the healthcare and commercial default. John Deere 6068HG550 with Decision-Maker controller.
150 kW standby · Diesel · Liquid-cooled
150 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
154 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 150REOZJF
THD below 3% at 154 kW -- the healthcare and commercial default. John Deere 6068HF285K with Decision-Maker controller.
154 kW standby · Diesel · Liquid-cooled
154 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
154 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 1600REOZMD
1600 kW industrial diesel -- Mitsubishi S16R-Y2PTAW-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1600 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
1560 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1560 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
3-phasedata-centerhealthcare
Kohler
Kohler 1750REOZMD
1780 kW industrial diesel -- Mitsubishi S16R-Y2PTAW2-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
1.8 MW standby · Diesel · Liquid-cooled
1780 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1780 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 175REOZT4
150 kW mobile diesel trailer -- Tier 4 John Deere 6068HG550. DOT-towable for large temporary power and emergency deployment.
150 kW standby · Diesel · Liquid-cooled
150 kW mobile standby for large construction projects, event power, emergency response, and planned outage bridge power.
154 kW diesel mobile trailer Tier 4 Final commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 4 Final3-phasecommercialhealthcare
Kohler
Kohler 180REOZJG
THD below 3% at 180 kW -- the healthcare and commercial default. John Deere 6068HFG82E with Decision-Maker controller.
180 kW standby · Diesel · Liquid-cooled
180 kW commercial standby for hospitals, schools, retail, and institutional facilities requiring clean power and NFPA 110 compliance.
180 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 2000REOZMD
2000 kW industrial diesel -- Mitsubishi S16R-Y2PTAW2-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
2 MW standby · Diesel · Liquid-cooled
2000 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
2000 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
1760 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1760 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
3-phasedata-centerhealthcare
Kohler
Kohler 230REOZJE
230 kW diesel standby with sub-3% THD -- John Deere 6090HF484C. Healthcare and data center default in this power class.
230 kW standby · Diesel · Liquid-cooled
230 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
230 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 2500REOZDC
2500 kW industrial diesel -- Detroit Diesel/MTU 16V4000G83L with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
2500 kW diesel industrial generator powered by Detroit Diesel/MTU. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 250REOZJE
255 kW diesel standby with sub-3% THD -- John Deere 6090HF484B. Healthcare and data center default in this power class.
255 kW standby · Diesel · Liquid-cooled
255 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
255 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 275REOZJE
280 kW diesel standby with sub-3% THD -- John Deere 6090HF484A. Healthcare and data center default in this power class.
280 kW standby · Diesel · Liquid-cooled
280 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
280 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 300REOZJ
300 kW diesel standby with sub-3% THD -- John Deere 6090HFG86. Healthcare and data center default in this power class.
300 kW standby · Diesel · Liquid-cooled
300 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
300 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJ
350 kW diesel standby with sub-3% THD -- John Deere 6135HF485T. Healthcare and data center default in this power class.
350 kW standby · Diesel · Liquid-cooled
350 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJB
360 kW diesel standby with sub-3% THD -- John Deere 6135HFG84B. Healthcare and data center default in this power class.
360 kW standby · Diesel · Liquid-cooled
360 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJC
350 kW diesel standby with sub-3% THD -- John Deere 6135HF485T. Healthcare and data center default in this power class.
350 kW standby · Diesel · Liquid-cooled
350 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 350REOZJD
360 kW diesel standby with sub-3% THD -- John Deere 6135HFG84B. Healthcare and data center default in this power class.
360 kW standby · Diesel · Liquid-cooled
360 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 400REOZJ
400 kW diesel standby with sub-3% THD -- John Deere 6135HF485S. Healthcare and data center default in this power class.
400 kW standby · Diesel · Liquid-cooled
400 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
400 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 400REOZJC
400 kW diesel standby with sub-3% THD -- John Deere 6135HF485S. Healthcare and data center default in this power class.
400 kW standby · Diesel · Liquid-cooled
400 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
400 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 400REOZJD
410 kW diesel standby with sub-3% THD -- John Deere 6135HFG84A. Healthcare and data center default in this power class.
410 kW standby · Diesel · Liquid-cooled
410 kW commercial standby for hospitals, data centers, government, and mid-size facilities requiring NFPA 110 Level 1.
410 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.
Tier 33-phasecommercialhealthcare
Kohler
Kohler 500REOZJ
500 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
500 kW standby · Diesel · Liquid-cooled
500 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
500 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REOZJB
510 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
510 kW standby · Diesel · Liquid-cooled
510 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
510 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REOZVC
515 kW diesel standby -- Volvo TAD1641GE-B, sub-3% THD. Decision-Maker controller for load management and paralleling.
515 kW standby · Diesel · Liquid-cooled
515 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
515 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 550REOZVB
550 kW diesel standby -- Volvo TAD1642GE-B, sub-3% THD. Decision-Maker controller for load management and paralleling.
550 kW standby · Diesel · Liquid-cooled
550 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
550 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 600REOZVB
600 kW diesel standby -- Volvo TWD1643GE, sub-3% THD. Decision-Maker controller for load management and paralleling.
600 kW standby · Diesel · Liquid-cooled
600 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
600 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 750REOZMD
760 kW diesel standby -- Mitsubishi S12A2-Y2PTAW-2, sub-3% THD. Decision-Maker controller for load management and paralleling.
760 kW standby · Diesel · Liquid-cooled
760 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
760 kW diesel commercial/industrial standby generator powered by Mitsubishi. Suitable for hospitals, data centers, and large commercial complexes.
1250 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1250 kW EPA Tier 4 Final diesel industrial standby generator. Dual-certified (emergency and non-emergency) for mission-critical and prime power applications.
1750 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1750 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2000
2000 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2 MW standby · Diesel · Liquid-cooled
2000 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2000 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure requiring multi-megawatt backup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2250
2250 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.3 MW standby · Diesel · Liquid-cooled
2250 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2250 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical facilities approaching 2 MW.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2500
2500 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2500 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and heavy industrial facilities requiring 2+ MW backup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2500-4
2500 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2500 kW EPA Tier 4 Final diesel industrial standby generator. Dual-certified (emergency and non-emergency) for mission-critical and prime power applications.
Tier 4 Final3-phasedata-centerhealthcare
Kohler
Kohler KD2800
2800 kW KD Series -- Kohler KD83V16 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.8 MW standby · Diesel · Liquid-cooled
2800 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2800 kW diesel industrial standby generator. Upper-range KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD3000
3000 kW KD Series -- Kohler KD83V16 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3 MW standby · Diesel · Liquid-cooled
3000 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3000 kW diesel industrial standby generator. Upper-range KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD3250
3250 kW KD Series -- Kohler KD83V16 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3.3 MW standby · Diesel · Liquid-cooled
3250 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3250 kW diesel industrial standby generator. Upper-range KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD3250-4
3250 kW KD Series -- Kohler KD83V16 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3.3 MW standby · Diesel · Liquid-cooled
3250 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3250 kW EPA Tier 4 Final diesel industrial standby generator. Dual-certified (emergency and non-emergency) for mission-critical and prime power applications.
Tier 4 Final3-phasedata-centerhealthcare
Kohler
Kohler KD3500
3500 kW KD Series -- Kohler KD103V20 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3.5 MW standby · Diesel · Liquid-cooled
3500 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3500 kW diesel industrial standby generator. Near-top-of-line KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD4000
4000 kW KD Series -- Kohler KD103V20 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
4 MW standby · Diesel · Liquid-cooled
4000 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
4000 kW diesel industrial standby generator. Flagship KD Series platform — the largest single-engine generator in Kohler's industrial lineup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD900
900 kW KD Series -- Kohler KD27V12 with sub-3% THD and PM pilot exciter. Clean power for sensitive loads.
900 kW standby · Diesel · Liquid-cooled
900 kW industrial standby for data centers, hospitals, and mission-critical facilities requiring premium power quality and NFPA 110 Level 1.
900 kW diesel industrial standby generator. Entry-level KD Series platform for data centers, healthcare, and mission-critical facilities.
Tier 23-phasedata-centerhealthcare
MQ Power
MQ Power DCA-125 WhisperWatt
WhisperWatt 125 kVA — 66 dBA at 7m, Isuzu BR-4HK1X 5.2L, 169-gal tank for 24-hr runtime at full load. DEF/SCR Tier 4 Final.
110 kW standby · Diesel · Liquid-cooled
Large portable at 100 kW prime. Diesel at 7.11 gph, 169-gal tank minimizes refueling, commercial backup and large events.
125 kVA (100 kW prime) portable diesel generator. Mid-large WhisperWatt Super-Silent for commercial construction, events, and emergency power.
Tier 4 Final3-phaseconstruction-largerental-fleet
MQ Power
MQ Power DCA-150 WhisperWatt
WhisperWatt 150 kVA — John Deere 6068HFG05 6.8L inline-6, 66 dBA, 319-gal tank for 36-hr full-load runtime. JD dealer network parts.
132 kW standby · Diesel · Liquid-cooled
Major construction/disaster recovery at 120 kW prime. Diesel at 8.9 gph, 319-gal tank for 5-7 day deployments, Tier 4 Final.
150 kVA (120 kW prime) portable diesel generator. John Deere-powered WhisperWatt Super-Silent for major construction, large events, and emergency commercial power.
WhisperWatt by Denyo — 65 dBA at 7m, quietest in class. Isuzu 4LE2T at 1800 RPM, 1.62 gph, switchable single/three-phase, Tier 4 Final.
22 kW standby · Diesel · Liquid-cooled
Rental fleet workhorse at 20 kW prime. Diesel at 1.62 gph, 41.7-gal tank for 25+ hr runtime, noise-sensitive job sites and events.
25 kVA (20 kW prime) portable diesel generator. Quiet WhisperWatt Super-Silent construction workhorse for rental fleets, job sites, and temporary power.
Tier 4 Final3-phaseconstructionrental-fleet
MQ Power
MQ Power DCA-300 WhisperWatt
WhisperWatt 300 kVA — JD 6090HFG06 9.0L inline-6, 72 dBA, 430-gal tank, paralleling capable. Largest JD-powered WhisperWatt.
264 kW standby · Diesel · Liquid-cooled
Major construction/disaster recovery at 240 kW prime. Diesel at 16.7 gph, 430-gal tank for multi-day ops, data center temp power.
300 kVA (240 kW prime) portable diesel generator. Large WhisperWatt for major construction, events, and emergency commercial power.
Tier 4 Final3-phaseconstruction-majorrental-fleet
MQ Power
MQ Power DCA-400 WhisperWatt
WhisperWatt 400 kVA — top of lineup. Isuzu BG-6WG1X 6-cyl, 69 dBA (quieter than DCA-300), CARB compliant for California job sites.
336 kW standby · Diesel · Liquid-cooled
Largest WhisperWatt at 320 kW prime. Diesel at 22.5 gph, 405-gal tank, CARB + Tier 4 Final, infrastructure and data center temp.
400 kVA (320 kW prime) portable diesel generator. The largest WhisperWatt Super-Silent for major construction, infrastructure, and large-scale emergency power.
Tier 4 Final3-phaseconstruction-majorrental-fleet
MQ Power
MQ Power DCA-45 WhisperWatt
WhisperWatt 45 kVA — 66 dBA at 7m, Isuzu 4LE2X 2.93L, no DEF required (DPF+EGR only), switchable phase output, 79-gal tank.
40 kW standby · Diesel · Liquid-cooled
Mid-size portable at 36 kW prime. Diesel at 2.93 gph, no DEF logistics, construction and events up to 36 kW.
45 kVA (36 kW prime) portable diesel generator. Compact WhisperWatt Super-Silent for construction sites, events, and commercial temporary power.
Tier 4 Final3-phaseconstruction-largerental-fleet
MQ Power
MQ Power DCA-70 WhisperWatt
WhisperWatt 70 kVA — 65 dBA at 7m (same as DCA-25). Isuzu BR-4JJ1X 3.0L, DEF/SCR Tier 4 Final, 103-gal tank, switchable phase.
62 kW standby · Diesel · Liquid-cooled
Commercial temporary power at 56 kW prime. Diesel at 4.4 gph, 103-gal tank for multi-day runtime, film and events.
70 kVA (56 kW prime) portable diesel generator. Quiet WhisperWatt Super-Silent for large construction sites, commercial events, and emergency temporary power.
Tier 4 Final3-phaseconstruction-largerental-fleet
M
MTU
MTU 10V1600 DS500
500 kW diesel standby on MTU 10V1600 V10 — 17.5L, ADEC isochronous ±0.25%, PMG alternator with 300% short-circuit, 33 gph, 20K-hr overhaul.
500 kW standby · Diesel · Liquid-cooled
Data center and critical facility standby at 500 kW. Diesel at 33 gph, PMG for UPS compatibility, NFPA 110 single-step.
500 kW diesel standby generator with MTU 10V1600G80S 17.5L common-rail V10 engine, EPA Tier 2, 208–600V three-phase, PMG alternator, ADEC isochronous governor. 3416 x 1873 x 2032 mm.
Industrial/data center standby at 600 kW. Diesel at 40 gph, 12-cyl V platform, PMG for UPS and motor starting.
600 kW diesel standby generator with MTU 12V1600G80S 21.0L common-rail V12 engine, EPA Tier 2, 208–600V three-phase, PMG alternator, ADEC isochronous governor. 3737 x 1899 x 2137 mm.
Tier 23-phasecommercial-standbyindustrial-standby
M
MTU
MTU 12V1600 DS750
750 kW diesel standby — 12V1600 sweet spot. Same footprint as DS600/DS900, 50°C radiator, 51 gph, Leroy-Somer alternator.
750 kW standby · Diesel · Liquid-cooled
Healthcare/data center/high-rise standby at 750 kW. Diesel at 51 gph, compact for sub-MW class, SCAQMD + NFPA 110.
750 kW Tier 2 diesel standby generator. mtu 12V1600G71S engine, 22.44L V-12 with turbocharging and aftercooling, LSA 49.3 M8 alternator.
Tier 23-phasecommercial-standbyindustrial
M
MTU
MTU 12V1600 DS900
900 kW diesel standby — max output from 12V1600 platform. Same footprint as DS600/DS750, 62 gph, 996 kWm gross. Compact sub-MW.
900 kW standby · Diesel · Liquid-cooled
Large commercial/data center standby at 900 kW. Diesel at 62 gph, compact 178 in footprint, 40°C radiator rating.
900 kW Tier 2 diesel standby generator. mtu 12V1600G91S engine, 22.44L V-12 with turbocharging and aftercooling, LSA 49.3 L9 alternator.
Tier 23-phasecommercial-standbyindustrial
M
MTU
MTU 12V2000 DS800
800 kW diesel standby — MTU 2000-series V12, 23.9L. Medium-voltage 4,160V option, EUP injection, separate intercooler circuit, 59 gph.
800 kW standby · Diesel · Liquid-cooled
Industrial/hospital standby at 800 kW. Diesel at 59 gph, 4,160V medium-voltage available, 20K-hr overhaul interval.
800 kW diesel standby generator with MTU 12V2000G85TB 23.9L V12 engine, EPA Tier 2, 208–4160V including medium voltage, electronic unit pump injection, ADEC governor. 4675 x 2292 x 2341 mm, 17,379 lb.
Data center continuous power at 1,600 kW DCCP. Diesel at 111 gph, flagship 12-cyl, HVO renewable fuel compatible.
1,750 kW standby / 1,600 kW DCCP diesel generator from MTU (Rolls-Royce). 57.2L V12 engine, EPA Tier 2 + SCAQMD, 380-13,800V. Maximum continuous output from the 12-cylinder Series 4000.
Tier 23-phasedata-centerhospital-large
M
MTU
MTU 20V4000 DS2800
2,800 kW diesel standby — MTU 20V4000 95.4L V20. Medium/high-voltage to 13.8kV, ADEC ±0.25%, 20K-hr overhaul, 186 gph.
2.8 MW standby · Diesel · Liquid-cooled
Utility-scale standby at 2.8 MW. Diesel at 186 gph, 480V-13.8kV direct MV connection, 62,000 lb installation.
2800 kW diesel standby generator with MTU 20V4000G83 95.4L 20-cylinder V common-rail engine, EPA Tier 2, 380V–13.8kV including medium voltage, ADEC governor, 7626 x 3099 x 3569 mm, 62,056 lb.
Tier 23-phasecommercial-standbyindustrial-standby
M
MTU
MTU 20V4000 DS3250
3,250 kW diesel standby — top of the MTU product line. 95.4L V20 at 3,490 kWm, 480V-13.8kV, standby-only, 223 gph.
3.3 MW standby · Diesel · Liquid-cooled
Maximum single-unit standby at 3.25 MW. Diesel at 223 gph, 480V-13.8kV medium-voltage, 65,000+ lb power plant.
3250 kW diesel standby generator with MTU 20V4000G83L 95.4L 20-cylinder V common-rail engine, EPA Tier 2, 480V–13.8kV medium and high voltage, ADEC governor. 7766 x 3099 x 3569 mm, 65,369 lb.
Tier 23-phasecommercial-standbyindustrial-standby
M
MTU
MTU 3R0096 DS30
Compact 30 kW diesel standby on John Deere 3029 platform. 2.6 gph full load, 50°C radiator, NFPA 110 single-step load acceptance.
30 kW standby · Diesel · Liquid-cooled
Small commercial standby for offices and light-industrial sites under 30 kW. Diesel at 2.6 gph, UL 2200 eligible.
30 kW EPA Tier 3 diesel standby generator with John Deere 3029TFG89 engine, 2.9 L 3-cylinder, 1800 rpm. Unit-mounted radiator rated for 50°C ambient. UL 2200 offered.
Tier 33-phasecommercial-standbylight-industrial
M
MTU
MTU 4R0113 DS100
100 kW diesel standby with turbo JD 4045HF285 and JDEC electronic isochronous governor (±0.25%). SCAQMD certified, OSHPD eligible.
100 kW standby · Diesel · Liquid-cooled
Commercial/healthcare standby at 100 kW. Diesel at 8.2 gph, SCAQMD + NFPA 110 single-step load, data center edge.
100 kW EPA Tier 3 diesel standby generator with John Deere 4045HF285 engine, 4.5 L turbocharged-aftercooled 4-cylinder, JDEC electronic isochronous governor.
Tier 33-phasecommercial-standbylight-industrial
M
MTU
MTU 4R0113 DS50
50 kW diesel standby with mechanical injection John Deere 4045TF280. Simple maintenance, no ECU — robust cold-start, 4.6 gph full load.
50 kW standby · Diesel · Liquid-cooled
Small commercial standby for offices and retail under 50 kW. Diesel at 4.6 gph, mechanical governor for straightforward service.
50 kW EPA Tier 3 diesel standby generator with John Deere 4045TF280 engine, 4.5 L 4-cylinder mechanical injection, 1800 rpm. UL 2200 offered, 50°C radiator.
Tier 33-phasecommercial-standbylight-industrial
M
MTU
MTU 6R0113 DS150
150 kW diesel standby on JD 6068HF285 inline-6. Smoother vibration than 4-cyl alternatives, SCAQMD certified, OSHPD eligible, 11.8 gph.
150 kW standby · Diesel · Liquid-cooled
Healthcare and commercial standby at 150 kW. Diesel at 11.8 gph, 6-cyl smooth operation, NFPA 110 single-step load.
150 kW EPA Tier 3 diesel standby generator with John Deere 6068HF285 engine, 6.8 L turbocharged-aftercooled 6-cylinder inline, JDEC governor, 1800 rpm.
Tier 33-phasecommercial-standbylight-industrial
M
MTU
MTU 6R0113 DS200
200 kW diesel standby — max output from the JD 6068 platform. 15.5 gph, SCAQMD certified, OSHPD eligible, isochronous ±0.25%.
200 kW standby · Diesel · Liquid-cooled
Healthcare and commercial standby at 200 kW. Diesel at 15.5 gph, highest R-series inline output, data center edge.
200 kW EPA Tier 3 diesel standby generator with John Deere 6068HFG85 engine, 6.8 L turbocharged 6-cylinder inline, JDEC electronic isochronous governor, 1800 rpm.