Triton Power · TP-V

Triton Power TP-V550-T4F

550 kW standby / 500 kW prime · Diesel · Liquid-cooled

550 kW Tier 4 Final diesel generator with Volvo TWD1672GE engine. For commercial, industrial, and data center standby applications.

Triton Power Triton Power TP-V550-T4F generator — specifications and details
Standby power
550 kW / 500 kW prime
Voltage options
120/208V, 277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Volvo TWD1672GE · 16.1L
EPA / Emissions
Tier 4 Final
Alternator
Leroy Somer LSA47.2

Overview#

The Triton Power TP-V550-T4F is a 550 kW diesel standby generator powered by the Volvo TWD1672GE turbocharged six-cylinder engine (16.1 L displacement). This is one of Triton's Tier 4 Final nonroad-certified units, paired with a Leroy Somer alternator. Available in three-phase only at 120/208V and 277/480V, the unit includes a 264-gallon (1,000 L) integral fuel tank with 125% fluid containment.

The Volvo TWD1672GE produces 585 kWm (784 HP) at 1800 RPM. Fuel consumption is 99.1 L/hr (26.18 GPH) at full load, dropping to 51.2 L/hr (13.53 GPH) at half load. The unit uses a Deep Sea Electronics DSE7420 controller and is available in open, enclosed, and mobile configurations with sub-base tank options up to 45 hours runtime.

The Volvo TWD engine advantage#

The Volvo TWD1672GE represents Triton's Tier 4 Final offering in the 500-550 kW class, complementing the Perkins-powered Tier 2/3 models at similar ratings. Volvo's TWD engine platform is widely used in power generation across brands like SDMO and Atlas Copco, providing good parts availability through Volvo Penta's global dealer network. The Tier 4 Final certification makes this unit suitable for nonroad mobile and rental applications where emissions compliance is required.

Our service experience#

At 550 kW, this Volvo-powered unit fills the gap between Triton's Perkins 2506C-powered 500 kW model and the 2806C-powered 600 kW model. The Volvo engine is a familiar platform for shops already servicing Volvo-powered generators from other OEMs. In Northern California, Tier 4 Final units are increasingly specified for construction, rental fleet, and mobile power applications where air quality regulations are strict.

Engineering specifications

Physical

Length
204.7 in
Width
74.8 in
Height
98.4 in
Dry weight
18,506 lb

Acoustic

Sound @ 7m, full load
70 dBA

Fuel system & runtime

Integral fuel tank
264 gal
Fuel use @ full load
26.18 GPH
Fuel use @ 75% load
18.62 GPH
Fuel use @ 50% load
13.53 GPH

Ready to order this model?

Configure your Triton Power TP-V550-T4F

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Triton Power TP-V550-T4F

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

13.1 hours(0.5 days)

Fuel consumption ≈ 20.20 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Frequently Asked Questions

What engine powers the Triton TP-V550-T4F?
The TP-V550-T4F uses a Volvo TWD1672GE turbocharged six-cylinder diesel engine with 16.1 L displacement, producing 585 kWm (784 HP) at 1800 RPM. It meets EPA Tier 4 Final emissions standards for nonroad applications.
What are the dimensions and weight of the TP-V550-T4F?
The enclosed unit measures approximately 205 inches long x 75 inches wide x 98 inches high (5200 x 1900 x 2500 mm) with a dry weight of 18,508 lbs (8,394 kg).
How does the TP-V550-T4F differ from the TP-P500-T2-UL?
The TP-V550 uses a Volvo engine with Tier 4 Final certification for nonroad/mobile applications, while the TP-P500 uses a Perkins engine with Tier 2 for emergency stationary use. The Volvo unit offers 50 kW more power and emissions compliance for rental and mobile deployments.
What is the fuel tank capacity of the TP-V550-T4F?
The TP-V550-T4F includes a 264-gallon (1,000 L) integral fuel tank with 125% fluid containment for environmental protection.

Why we recommend Triton Power

Triton Power is our value brand for mobile and portable diesel generators, and an emerging option for industrial standby. When MQ Power's pricing is a stretch or lead times are too long, Triton delivers comparable capability at a lower price point with faster availability.

We are developing our Triton Power sales relationship and building fleet experience. Every engine platform Triton uses — Perkins, John Deere, Kubota, Scania, Volvo — is one we already service daily across other brands. Triton's open architecture means our technicians can maintain these units with standard tooling and widely available parts.

See all Triton Powergenerators →

Similar models

Triton Power Triton Power TP-P500-T2-UL 500 kW liquid-cooled standby generator

Triton Power

Triton Power TP-P500-T2-UL

500 kW standby · Diesel · Liquid-cooled

500 kW Tier 2 diesel generator with Perkins 2506D-E15TAG3 engine. UL2200-listed for commercial and industrial standby applications.

Tier 23-phasecommercial-standbyindustrial-light
Triton Power Triton Power TP-P600-T2-UL 600 kW liquid-cooled standby generator

Triton Power

Triton Power TP-P600-T2-UL

600 kW standby · Diesel · Liquid-cooled

600 kW Tier 2 diesel generator with Perkins 2806C-E18TAG3 engine. UL2200-listed for commercial, industrial, and data center standby.

Tier 23-phasecommercial-standbyindustrial

Triton Power

Triton Power TP-V600-T2-UL

600 kW standby · Diesel · Liquid-cooled

600 kW Tier 2 UL-listed diesel generator with Volvo TAD1641GE engine. For commercial and industrial standby applications.

Tier 23-phasecommercial-standbyindustrial

Need service or parts for the Triton Power TP-V550-T4F?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: